Cited by 66Non-Invasive Vital Sign MonitoringAdvanced Sensor and Energy Harvesting MaterialsContext-Aware Activity Recognition Systems

A Wearable, Multimodal Sensing System to Monitor Knee Joint Health

Teague, Caitlin N., Heller, J. Alex, Nevius, Brandi N., Carek, Andrew M., Mabrouk, Samer, Garcia-Vicente, Florencia, Inan, Omer T., Etemadi, Mozziyar·2020·IEEE Sensors Journal

Abstract

Objective: We designed and validated a wearable, multimodal sensor brace for knee joint health assessment. Methods: An embedded-, two-microcontroller-based approach is used to sample high-throughput, multi-microphone joint acoustics (46.875 kHz) as well as lower-rate electrical bioimpedance (EBI) (1/46.17 s), inertial (100 - 250 Hz), and skin temperature (1 Hz) data, and these data are saved onto microSD cards. Additionally, a flexible, 3D-printed brace houses the custom circuit boards and sensors to enable wearable sensing. Results: The system achieves 9 hours of continuous joint sound recording, while the EBI, inertial, and temperature sensors can sample for 35 hours using 500 mAh batteries. Further, for the entirety of these continuous recordings, there were no dropped samples for any of the sensors. Lastly, proof-of-concept measurements were used to show the system's efficacy for recording joint sounds and swelling data. Conclusion: This is, to the best of our knowledge, the first, completely untethered wearable system for multimodal knee health monitoring. Significance: The proposed smart brace may facilitate in-clinic or at-home measurements for joint health assessment.

Integrity signals

Registry

Crossref · 10.1109/jsen.2020.2994552

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Teague, C. N., Heller, J. A., Nevius, B. N., Carek, A. M., Mabrouk, S., Garcia-Vicente, F., Inan, O. T., & Etemadi, M.
Affiliations
  • Georgia Institute of Technology (US)
  • Northwestern University (US)
Venue
IEEE Sensors Journal
Published
2020-09-15
Volume
20
Issue
18
Pages
10323-10334
ISSN
  • 1530-437X (ISSN-L)
  • 1558-1748
  • 2379-9153
OpenAlex
W3025531568
Cited by
66
References
37
Citations by year
2026: 8 · 2025: 7 · 2024: 7 · 2023: 8 · 2022: 18 · 2021: 17 · 2020: 1
FWCI
3.46
Type
journal article
Language
en
Open access
closed
Locations
IEEE Sensors Journal (publishedVersion)
Funders
Defense Advanced Research Projects Agency (DARPA) Biological Technologies Office (BTO) ElectRx program through the Naval InformationWarfare Center (N66001-19-2-4002)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
Keywords
wearable sensors, multimodal sensing, bioimpedance, inertial sensors, skin temperature, microcontroller data acquisition, knee swelling, home monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review