Cited by 69Wireless Power Transfer SystemsWireless Body Area NetworksElectromagnetic Fields and Biological Effects

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

A Biosafety Comparison Between Capacitive and Inductive Coupling in Biomedical Implants

Al-Kalbani, Ahmed I., Yuce, Mehmet R., Redoute, Jean-Michel·2014·IEEE Antennas and Wireless Propagation Letters

Abstract

This letter investigates the link efficiencies and ensuing biohazards when capacitive versus inductive coupling is used to power biomedical implants electromagnetically. Electromagnetic simulations illustrate that the power link efficiency of capacitive coupling decays slower as a function of the distance between plates compared to inductive coupling. Specifically, the case designs show that, using a transmitted power of 1 W at 5 MHz, capacitive coupling produces a 10-g averaged SAR value of 1.63 W/kg compared to 2.39 W/kg for an inductive coupling of the same dimension.

Overview

Integrity signals

Registry

Crossref · 10.1109/lawp.2014.2328375

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 7 references

Research works printed but not linked: 1

  1. 1998, ICNIRP guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz), Health Phys, 74, 494

Cited by

Sorted by citations

Metadata

Authors
Al-Kalbani, A. I., Yuce, M. R., & Redoute, J.-M.
Affiliations
Monash University (AU)
Venue
IEEE Antennas and Wireless Propagation Letters
Published
2014
Volume
13
Pages
1168-1171
ISSN
  • 1536-1225 (ISSN-L)
  • 1548-5757
OpenAlex
W2109992268
Cited by
69
References
7
Citations by year
2026: 4 · 2025: 5 · 2024: 5 · 2023: 7 · 2022: 12 · 2021: 7 · 2020: 4 · 2019: 7 · 2018: 6 · 2017: 6 · 2016: 3 · 2015: 3
FWCI
2.13
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Antennas and Wireless Propagation Letters (publishedVersion)
  • ORBi (University of Liège) (submittedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
Keywords
capacitive coupling, inductive coupling, biomedical implants, link efficiency, specific absorption rate, biological hazards, electromagnetic simulation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review