A Charge-Plasma-Based Dielectric-Modulated Junctionless TFET for Biosensor Label-Free Detection

Singh, Deepika, Pandey, Sunil, Nigam, Kaushal, Sharma, Dheeraj, Yadav, Dharmendra Singh, Kondekar, Pravin · 2017 · IEEE Transactions on Electron Devices

Abstract

To reduce the fabrication complexity and cost of the nanoscale devices, a charge-plasma concept is introduced for the first time to implement a dielectric-modulated junctionless tunnel field-effect transistor (DM-JLTFET) for biosensor label-free detection. The formation of p+source and n+drain regions in DM-JLTFET is done by the deposition of platinum (work function = 5.93 eV) and hafnium (work function = 3.9 eV) materials, respectively, over the silicon body. Furthermore, a nanogap cavity embedded within the gate dielectric is created by etching the portion of gate oxide layer toward the source end for sensing biomolecules. For this, the sensing capability of DM-JLTFET has been investigated in terms of variation in dielectric constant, charge density, length, and thickness of the cavity at different bias conditions. Finally, a comparative study between DM-JLTFET and MOSFET biosensor is investigated. The implementation of proposed device and all the simulations have been performed by using ATLAS device simulator.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/ted.2016.2622403

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 237

Metadata

Authors
Singh, D., Pandey, S., Nigam, K., Sharma, D., Yadav, D. S., & Kondekar, P.
Venue
IEEE Transactions on Electron Devices
Published
2017-01
Volume
64
Issue
1
Pages
271-278
ISSN
  • 0018-9383 (ISSN-L)
  • 1557-9646
OpenAlex
W2551832971
Cited by
237
References
4
FWCI
5.79
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Charge-Plasma-Based Dielectric-Modulated Junctionless TFET for Biosensor Label-Free Detection. https://app.cochat.ai/papers/10.1109/ted.2016.2622403
The paper
Singh, D., Pandey, S., Nigam, K., Sharma, D., Yadav, D. S., & Kondekar, P. (2017). A Charge-Plasma-Based Dielectric-Modulated Junctionless TFET for Biosensor Label-Free Detection. IEEE Transactions on Electron Devices. https://doi.org/10.1109/ted.2016.2622403

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.