The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Curvature, Torsion, and Force Sensing in Continuum Robots Using Helically Wrapped FBG Sensors
Abstract
Due to their small size and flexibility, fiber Bragg grating (FBG) sensors have been integrated into needle-sized continuum robots for shape estimation and force measurement. The challenge in extending previous shape and force sensing technologies to pre-curved continuum robots, such as concentric-tube robots, is that torsion information is essential for accurate shape estimation, and the force-strain relationship is nonlinear. In this letter, a novel helically wrapped FBG sensor design and corresponding force-curvature-strain model are developed to provide simultaneous curvature, torsion, and force measurement. To validate this design and modeling technique, two sensorized Nitinol tubes were fabricated and tested in an experimental setup. The results showed that accurate and sensitive curvature, torsion, and force measurements can be obtained at a 100 Hz sampling rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yokoyama, K., Nakagawa, H., Shah, D. C., Lambert, H., Leo, G., Aeby, N., Ikeda, A., Pitha, J. V., Sharma, T., Lazzara, R., et al. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.803650 · Cited by 624
Mechanics of Precurved-Tube Continuum Robots
Webster, R. J., Romano, J. M., & Cowan, N. J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.2006868 · Cited by 485
(2006) · Springer eBooks · doi:10.1007/978-1-4020-5483-9 · Cited by 360
Three-Dimensional Needle Shape Reconstruction Using an Array of Fiber Bragg Grating Sensors
Roesthuis, R. J., Kemp, M., van den Dobbelsteen, J. J., & Misra, S. (2014) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2013.2269836 · Cited by 281
Real-Time Estimation of 3-D Needle Shape and Deflection for MRI-Guided Interventions
Park, Y.-L., Elayaperumal, S., Daniel, B., Ryu, S. C., Shin, M., Savall, J., Black, R. J., Moslehi, B., & Cutkosky, M. R. (2010) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2010.2080360 · Cited by 266
Stiffness Control of Surgical Continuum Manipulators
Mahvash, M., & Dupont, P. E. (2011) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2105410 · Cited by 265
He, X., Handa, J., Gehlbach, P., Taylor, R., & Iordachita, I. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2283501 · Cited by 191
Iordachita, I., Sun, Z., Balicki, M., Kang, J. U., Phee, S. J., Handa, J., Gehlbach, P., & Taylor, R. (2009) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-009-0301-6 · Cited by 181
FBG-based shape sensing tubes for continuum robots
Ryu, S. C., & Dupont, P. E. (2014) · 2014 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2014.6907368 · Cited by 159
Shape Tracking of a Dexterous Continuum Manipulator Utilizing Two Large Deflection Shape Sensors
Liu, H., Farvardin, A., Grupp, R. B., Murphy, R. J., Taylor, R. H., Iordachita, I. I., & Armand, M. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2442266 · Cited by 82
Modeling, Force Sensing, and Control of Flexible Cannulas for Microstent Delivery
Wei, W., & Simaan, N. (2012) · Journal of Dynamic Systems Measurement and Control · doi:10.1115/1.4006080 · Cited by 50
Cited by
A decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Shape Sensing Techniques for Continuum Robots in Minimally Invasive Surgery: A Survey
Shi, C., Luo, X., Qi, P., Li, T., Song, S., Najdovski, Z., Fukuda, T., & Ren, H. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2622361 · Cited by 420
Fiber Optic Shape Sensors: A comprehensive review
Floris, I., Adam, J. M., Calderón, P. A., & Sales, S. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106508 · Cited by 316
Continuum Robots for Medical Interventions
Dupont, P. E., Simaan, N., Choset, H., & Rucker, C. (2022) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3141338 · Cited by 307
Challenges of continuum robots in clinical context: a review
da Veiga, T., Chandler, J. H., Lloyd, P., Pittiglio, G., Wilkinson, N. J., Hoshiar, A. K., Harris, R. A., & Valdastri, P. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab9f41 · Cited by 280
Metadata
- Authors
- Xu, R., Yurkewich, A., & Patel, R. V.
- Venue
- IEEE Robotics and Automation Letters
- Published
- 2016-07
- Volume
- 1
- Issue
- 2
- Pages
- 1052-1059
- ISSN
- 2377-3766 (ISSN-L)
- 2377-3774
- OpenAlex
- W2295380675
- Cited by
- 268
- References
- 11
- FWCI
- 10.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.