The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
A novel biometrics method to secure wireless body area sensor networks for telemedicine and m-health
Abstract
The development of the wireless body area sensor network (BASN) is imperative for modern telemedicine and m-health, but security remains a formidable challenge yet to be resolved. As nodes of BASN are expected to be interconnected on or in the human body, the body itself can form an inherently secure communication pathway that is unavailable to all other kinds of wireless networks. This article explores the use of this conduit in the security mechanism of BASN; that is, by a biometrics approach that uses an intrinsic characteristic of the human body as the authentication identity or the means of securing the distribution of a cipher key to secure inter-BASN communications. The method was tested on 99 subjects with 838 segments of simultaneous recordings of electrocardiogram and photoplethysmogram. By using the interpulse interval (IPI) as the biometric trait, the system achieved a minimum half total error rate of 2.58 percent when the IPIs measured from signals, which were sampled at 1000 Hz, were coded into 128-bit binary sequences. The study opens up a few key issues for future investigation, including compensation schemes for the asynchrony of different channels, coding schemes, and other suitable biometric traits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Juels, A., & Wattenberg, M. (1999) · Proceedings of the 6th ACM conference on Computer and communications security · doi:10.1145/319709.319714 · Cited by 1,591
Jovanov, E., Milenkovic, A., Otto, C., & de Groen, P. C. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-6 · Cited by 1,013
Biometric cryptosystems: issues and challenges
Uludag, U., Pankanti, S., Prabhakar, S., & Jain, A. K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2004.827372 · Cited by 921
Istepanian, R. S. H., Jovanov, E., & Zhang, Y. T. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.840019 · Cited by 766
Self-citationStaderini, E. M. (2002) · IEEE Aerospace and Electronic Systems Magazine · doi:10.1109/62.978359 · Cited by 496
Cuff-less and Noninvasive Measurements of Arterial Blood Pressure by Pulse Transit Time
Poon, C. C. Y., & Zhang, Y. T. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1615827 · Cited by 375
Self-citationTelemedicine: A New Health Care Delivery System
Bashshur, R. L., Reardon, T. G., & Shannon, G. W. (2000) · Annual Review of Public Health · doi:10.1146/annurev.publhealth.21.1.613 · Cited by 318
Cherukuri, S., Venkatasubramanian, K. K., & Gupta, S. K. S. (2003) · 2003 International Conference on Parallel Processing Workshops, 2003. Proceedings. · doi:10.1109/icppw.2003.1240399 · Cited by 308
Implementation of a WAP-based telemedicine system for patient monitoring
Hung, K., & Zhang, Y.-T. (2003) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2003.811870 · Cited by 290
Self-citationMobile Patient Monitoring: the MobiHealth System
Dimitri, K., Aart, V. H., Richard, B., Katarzyna, W., Ing, W., Nicolai, D., George, K., Val, J., & Rainer, H. (2004) · Studies in Health Technology and Informatics · doi:10.3233/978-1-60750-946-2-307 · Cited by 200
Bao, S.-D., Zhang, Y.-T., & Shen, L.-F. (2005) · 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference · doi:10.1109/iembs.2005.1616965 · Cited by 172
Self-citation
Cited by
Wireless Body Area Networks: A Survey
Movassaghi, S., Abolhasan, M., Lipman, J., Smith, D., & Jamalipour, A. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2013.121313.00064 · Cited by 1,538
A survey on ambient-assisted living tools for older adults
Rashidi, P., & Mihailidis, A. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2012.2234129 · Cited by 1,128
A survey on wireless body area networks
Latré, B., Braem, B., Moerman, I., Blondia, C., & Demeester, P. (2011) · Wireless Networks · doi:10.1007/s11276-010-0252-4 · Cited by 1,099
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
Self-citationA Survey on Wireless Body Area Networks: Technologies and Design Challenges
Cavallari, R., Martelli, F., Rosini, R., Buratti, C., & Verdone, R. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2014.012214.00007 · Cited by 710
Metadata
- Authors
- Poon, C. C. Y., Zhang, Y.-T., & Bao, S.-D.
- Venue
- IEEE Communications Magazine
- Published
- 2006-04
- Volume
- 44
- Issue
- 4
- Pages
- 73-81
- ISSN
- 0163-6804 (ISSN-L)
- OpenAlex
- W2122235704
- Cited by
- 570
- References
- 11
- FWCI
- 16.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.