Ambulatory monitoring of cumulative free-living activity
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Discusses potential clinical applications of monitoring patients with chronic obstructive pulmonary disease (COPD). It is concluded that the ability to measure cumulative free-living activity in patients with COPD appears to have enormous potential clinical applicability. Ongoing research to develop unobtrusive, wearable sensors that extend monitoring periods and couple these data with wireless technology is needed. Research studies are also needed to assess the role measurement of cumulative free-living activity plays in both the clinical care of patients with COPD and clinical trials involving COPD, therapeutics. It may prove to be optimally used alone or in conjunction with existing measures of clinical status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
Evidence-based health policy—lessons from the Global Burden of Disease Study
Murray, C. J. L., & Lopez, A. D. (1996) · Science · doi:10.1126/science.274.5288.740 · Cited by 2,178
Redelmeier, D. A., Bayoumi, A. M., Goldstein, R. S., & Guyatt, G. H. (1997) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.155.4.9105067 · Cited by 1,029
Ries, A. L., Kaplan, R. M., Limberg, T. M., & Prewitt, L. M. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-122-11-199506010-00003 · Cited by 903
Randomised controlled trial of respiratory rehabilitation
GOLDSTEIN, R. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90568-1 · Cited by 541 · cited 1×
“Pulmonary rehabilitation has been shown to improve symptoms, exercise capacity, and HRQL, even in the absence of improvement in lung function [16], [ 26 ]-[28].”
BackgroundThe prognostic value of exercise capacity: A review of the literature
Morris, C. K., Ueshima, K., Kawaguchi, T., Hideg, A., & Froelicher, V. F. (1991) · American Heart Journal · doi:10.1016/0002-8703(91)90586-7 · Cited by 237
Cited by
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
A review of smart homes—Present state and future challenges
Chan, M., Estève, D., Escriba, C., & Campo, E. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.02.001 · Cited by 1,007
Advances in wearable technology and applications in physical medicine and rehabilitation
Bonato, P. (2005) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-2-2 · Cited by 385
Wearable and Implantable Sensors for Biomedical Applications
Koydemir, H. C., & Ozcan, A. (2018) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061417-125956 · Cited by 289
A Multiparameter Wearable Physiologic Monitoring System for Space and Terrestrial Applications
Mundt, C. W., Montgomery, K. N., Udoh, U. E., Barker, V. N., Thonier, G. C., Tellier, A. M., Ricks, R. D., Darling, R. B., Cagle, Y. D., Cabrol, N. A., et al. (2005) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.854509 · Cited by 226
Metadata
- Authors
- Moy, M. L., Mentzer, S. J., & Reilly, J. J.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2003-05
- Volume
- 22
- Issue
- 3
- Pages
- 89-95
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2025224270
- Cited by
- 25
- References
- 6
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.