The DOI matches its Crossref record.
pH imaging
Abstract
Acid-base balance is altered in a variety of common pathologies, including COPD, ischemia, renal failure, and cancer. Because of robust cellular pH homeostatic mechanisms, most of the pathological alterations in pH are expressed as changes in the extracellular, systemic pH. There are data to indicate that altered pH is not simply an epiphenomenon of metabolic or physiologic imbalance but that chronic pH alterations can have important sequelae. MRSI and MRI measurements indicate that pH gradients of up to 1.0 pH unit can exit within 1-cm distance. Although measurement of blood pH can indicate systemic problems, it cannot pinpoint the lesion or quantitatively assess the magnitude of excursion from normal pHe. Hence, there is a need to develop pHe measurement methods with high spatiotemporal resolution. The two major approaches being investigated include magnetization transfer methods and relaxation methods. pH-dependent MT effects can observed with endogenous signals or exogenously applied CEST agents. While endogenous signals have the advantage of being fully noninvasive and relatively straightforward to apply, they lack a full biophysical characterization and dynamic range that might be afforded by future CEST agents. pH-dependent relaxivity also requires the injection or infusion of exogenous contrast reagents. In both MT and relaxographic approaches, the magnitude of the effect, and, thus, the ability to quantify pHe, depends on a spatially and temporally varying concentration of the CR. A number of approaches have been proposed to solve this problem and, once it is solved, pH imaging methods will be applicable to human clinical pathologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Magnetic resonance imaging of pH in vivo using hyperpolarized 13C-labelled bicarbonate
Gallagher, F. A., Kettunen, M. I., Day, S. E., Hu, D.-E., Ardenkjær-Larsen, J. H., Zandt, R. I. ‘., Jensen, P. R., Karlsson, M., Golman, K., Lerche, M. H., et al. (2008) · Nature · doi:10.1038/nature07017 · Cited by 849
2-hydroxyglutarate detection by magnetic resonance spectroscopy in IDH-mutated patients with gliomas
Choi, C., Ganji, S. K., DeBerardinis, R. J., Hatanpaa, K. J., Rakheja, D., Kovacs, Z., Yang, X.-L., Mashimo, T., Raisanen, J. M., Marin-Valencia, I., et al. (2012) · Nature Medicine · doi:10.1038/nm.2682 · Cited by 839
Kurhanewicz, J., Vigneron, D. B., Brindle, K., Chekmenev, E. Y., Comment, A., Cunningham, C. H., DeBerardinis, R. J., Green, G. G., Leach, M. O., Rajan, S. S., et al. (2011) · Neoplasia · doi:10.1593/neo.101102 · Cited by 681
Tumour hypoxia induces a metabolic shift causing acidosis: a common feature in cancer
Chiche, J., Brahimi‐Horn, M. C., & Pouysségur, J. (2010) · Journal of Cellular and Molecular Medicine · doi:10.1111/j.1582-4934.2009.00994.x · Cited by 667
Metadata
- Authors
- Gillies, R. J., Raghunand, N., Garcia-Martin, M. L., & Gatenby, R. A.
- Venue
- IEEE Engineering in Medicine and Biology Magazine
- Published
- 2004-09
- Volume
- 23
- Issue
- 5
- Pages
- 57-64
- ISSN
- 0739-5175 (ISSN-L)
- OpenAlex
- W2985100448
- Cited by
- 351
- References
- 0
- FWCI
- 4.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: pH imaging. https://app.cochat.ai/papers/10.1109/memb.2004.1360409
- The paper
- Gillies, R. J., Raghunand, N., Garcia-Martin, M. L., & Gatenby, R. A. (2004). pH imaging. IEEE Engineering in Medicine and Biology Magazine. https://doi.org/10.1109/memb.2004.1360409
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.