The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Grid-Connected Photovoltaic Generation Plants: Components and Operation
Open accessAbstract
The main design objective of photovoltaic (PV) systems has been, for a long time, to extract the maximum power from the PV array and inject it into the ac grid. Therefore, the maximum power point tracking (MPPT) of a uniformly irradiated PV array and the maximization of the conversion efficiency have been the main design issues. However, when the PV plant is connected to the grid, special attention has to be paid to the reliability of the system, the power quality, and the implementation of protection and grid synchronization functions. Modern power plants are required to maximize their energy production, requiring suitable control strategies to solve the problems related to the partial shading phenomena and different orientation of the PV modules toward the sun. Moreover, the new policy concerning the injection of reactive power into the grid makes the development of suitable topologies and control algorithms mandatory. A general view of actual solutions for applications of the PV energy systems is presented. This article covers several important issues, including the most reliable models used for simulation, which are useful in the design of control systems, and the MPPT function, particularly in distributed ?applications. The main topologies used in the PV power processing system and, finally, grid connection aspects are discussed, with emphasis on synchronization, protections, and integration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425
Comprehensive Approach to Modeling and Simulation of Photovoltaic Arrays
Villalva, M. G., Gazoli, J. R., & Filho, E. R. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2013862 · Cited by 4,390
Development of a photovoltaic arraymodel for use in power-electronics simulation studies
Gow, J. A., & Manning, C. D. (1999) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:19990116 · Cited by 1,104
Villanueva, E., Correa, P., Rodriguez, J., & Pacas, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029579 · Cited by 795
Highly Efficient Single-Phase Transformerless Inverters for Grid-Connected Photovoltaic Systems
Araujo, S. V., Zacharias, P., & Mallwitz, R. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2037654 · Cited by 636
Ishaque, K., & Salam, Z. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2200223 · Cited by 601
Reliability Issues in Photovoltaic Power Processing Systems
Petrone, G., Spagnuolo, G., Teodorescu, R., Veerachary, M., & Vitelli, M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924016 · Cited by 579
Self-citationShenoy, P. S., Kim, K. A., Johnson, B. B., & Krein, P. T. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2211082 · Cited by 460
Parallel-Connected Solar PV System to Address Partial and Rapidly Fluctuating Shadow Conditions
Gao, L., Dougal, R. A., Liu, S., & Iotova, A. P. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011296 · Cited by 456
Single-Phase Seven-Level Grid-Connected Inverter for Photovoltaic System
Rahim, N. A., Chaniago, K., & Selvaraj, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2064278 · Cited by 438
A Multilevel Inverter for Photovoltaic Systems With Fuzzy Logic Control
Cecati, C., Ciancetta, F., & Siano, P. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2044119 · Cited by 424
Power Electronics and Control Techniques for Maximum Energy Harvesting in Photovoltaic Systems
Femia, N., Petrone, G., Spagnuolo, G., & Vitelli, M. (2017) · CRC Press eBooks · doi:10.1201/b14303 · Cited by 421
Self-citationA Maximum Power Point Tracking Technique for Partially Shaded Photovoltaic Systems in Microgrids
Alajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2168796 · Cited by 404
An LLCL Power Filter for Single-Phase Grid-Tied Inverter
Wu, W., He, Y., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2161337 · Cited by 401
Cascaded DC–DC Converter Photovoltaic Systems: Power Optimization Issues
Bratcu, A. I., Munteanu, I., Bacha, S., Pïcault, D., & Raison, B. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2043041 · Cited by 375
A Modular Grid-Connected Photovoltaic Generation System Based on DC Bus
Zhang, L., Sun, K., Xing, Y., Feng, L., & Ge, H. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2064337 · Cited by 275
Long-Lifetime Power Inverter for Photovoltaic AC Modules
Rodriguez, C., & Amaratunga, G. A. J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.922401 · Cited by 258
Zhou, Y., Liu, L., & Li, H. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2219556 · Cited by 242
Cascaded H-bridge multilevel converter multistring topology for large scale photovoltaic systems
Rivera, S., Kouro, S., Wu, B., Leon, J. I., Rodriguez, J., & Franquelo, L. G. (2011) · 2011 IEEE International Symposium on Industrial Electronics · doi:10.1109/isie.2011.5984437 · Cited by 233
Self-citationA Parameterization Approach for Enhancing PV Model Accuracy
Mahmoud, Y. A., Xiao, W., & Zeineldin, H. H. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2230606 · Cited by 223
Self-citationEfficient Approaches for Modeling and Simulating Photovoltaic Power Systems
Xiao, W., Edwin, F. F., Spagnuolo, G., & Jatskevich, J. (2013) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2012.2226435 · Cited by 199
Self-citationOzdemir, E., Ozdemir, S., & Tolbert, L. M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.928096 · Cited by 194
Perturb and Observe MPPT algorithm with a current controller based on the sliding mode
Bianconi, E., Calvente, J., Giral, R., Mamarelis, E., Petrone, G., Ramos‐Paja, C. A., Spagnuolo, G., & Vitelli, M. (2012) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2012.07.046 · Cited by 159
Self-citationIssues on Solar-Generator Interfacing With Current-Fed MPP-Tracking Converters
Suntio, T., Leppäaho, J., Huusari, J., & Nousiainen, L. (2010) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2048580 · Cited by 111
Self-citationGrid-synchronization methods for power converters
Freijedo, F. D., Doval‐Gandoy, J., López, Ó., Martínez-Peñalver, C., Yepes, A. G., Fernandez-Comesaña, P., Malvar, J., Nogueiras, A., Marcos, J., & Lago, A. (2009) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2009.5414976 · Cited by 69
Shmilovitz, D., & Levron, Y. (2012) · Automatika · doi:10.7305/automatika.53-2.185 · Cited by 68
Boyra, M., & Thomas, J.-L. (2011) · HAL (Le Centre pour la Communication Scientifique Directe) · Cited by 44
Huusari, J., & Suntio, T. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2186318 · Cited by 41
Self-citationOptimizing photovoltaic model parameters for simulation
Soon, J. J., & Low, K. (2012) · IEEE International Symposium on Industrial Electronics (ISIE) · doi:10.1109/isie.2012.6237367 · Cited by 28
Huusari, J., & Suntio, T. (2012) · International Power Electronics and Motion Control Conference (IPEMC) · doi:10.1109/epepemc.2012.6397347 · Cited by 16
Self-citation
Cited by
Kouro, S., Leon, J. I., Vinnikov, D., & Franquelo, L. G. (2015) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2014.2376976 · Cited by 1,197
Self-citationLi, W., Gu, Y., Luo, H., Cui, W., He, X., & Xia, C. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2399278 · Cited by 671
Extended State Observer-Based Sliding-Mode Control for Three-Phase Power Converters
Liu, J., Vazquez, S., Wu, L., Marquez, A., Gao, H., & Franquelo, L. G. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2610400 · Cited by 509
Self-citationLeon, J. I., Vazquez, S., & Franquelo, L. G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2726583 · Cited by 481
Self-citationHu, J., Wang, Z., Liu, S., & Gao, H. (2016) · Automatica · doi:10.1016/j.automatica.2015.11.008 · Cited by 388
Metadata
- Authors
- Romero-Cadaval, E., Spagnuolo, G., Franquelo, L. G., Ramos-Paja, C. A., Suntio, T., & Xiao, W. M.
- Venue
- IEEE Industrial Electronics Magazine
- Published
- 2013-09
- Volume
- 7
- Issue
- 3
- Pages
- 6-20
- ISSN
- 1932-4529 (ISSN-L)
- OpenAlex
- W2079974359
- Cited by
- 449
- References
- 30
- FWCI
- 16.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.