Stretchable micro-electrode array [for retinal prosthesis]
The DOI matches its Crossref record.
Abstract
This paper focuses on the design considerations, fabrication processes, and preliminary testing of a retinal prosthesis that has the potential to aid in vision restoration to millions of blind patients. We are developing an implantable, stretchable micro-electrode array using polymer-based microfabrication techniques. The device will serve as the interface between an electronic imaging system and the human eye, directly stimulating retinal neurons via thin film conducting traces and electroplated electrodes. The metal features are embedded within a thin (/spl sim/50 /spl mu/m) substrate fabricated using poly (dimethylsiloxane) (PDMS), a biocompatible elastomeric material that has high oxygen permeability and low water permeability. The conformable nature of PDMS is critical for ensuring uniform contact with the curved surface of the retina. To fabricate the device, we developed unique processes for metalizing PDMS to produce robust traces capable of maintaining conductivity when stretched (strain = 7%, SD 1), and for selectively passivating the conductive elements. An in situ substrate curvature measurement taken while curing the PDMS revealed a tensile residual strain of 10%, explaining the stretchable nature of the thin metalized devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Stretchable Interconnects for Elastic Electronic Surfaces
Lacour, S. P., Jones, J., Wagner, S., Li, T., & Suo, Z. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.851502 · Cited by 621
Flexible and stretchable electrodes for dielectric elastomer actuators
Rosset, S., & Shea, H. R. (2013) · Applied Physics A · doi:10.1007/s00339-012-7402-8 · Cited by 529
Design and Performance of Thin Metal Film Interconnects for Skin-Like Electronic Circuits
Lacour, S. P., Jones, J., Suo, Z., & Wagner, S. (2004) · IEEE Electron Device Letters · doi:10.1109/led.2004.825190 · Cited by 260
Polymer micromachined multimodal tactile sensors
Engel, J., Chen, J., Fan, Z., & Liu, C. (2005) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2004.05.037 · Cited by 224
“PDMS elastomer is such a conformal material and work has recently been done showing that wires deposited on pre-stretched PDMS or electroplated in PDMS have maintained continuity even with elongation on the order of several percent [7,37].”
Background
Metadata
- Authors
- Maghribi, M., Hamilton, J., Polla, D., Rose, K., Wilson, T., & Krulevitch, P.
- Venue
- 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578)
- Publisher
- IEEE
- Published
- 2003-06-25
- Pages
- 80-83
- OpenAlex
- W1878530510
- Cited by
- 38
- References
- 0
- FWCI
- 7.28
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stretchable micro-electrode array [for retinal prosthesis]. https://app.cochat.ai/papers/10.1109/mmb.2002.1002269
- The paper
- Maghribi, M., Hamilton, J., Polla, D., Rose, K., Wilson, T., & Krulevitch, P. (2003). Stretchable micro-electrode array [for retinal prosthesis]. 2nd Annual International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology. Proceedings (Cat. No.02EX578). https://doi.org/10.1109/mmb.2002.1002269
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.