Basic parameters of coplanar-strip waveguides on multilayer dielectric/semiconductor substrates, part 1: high permittivity superstrates
The DOI matches its Crossref record.
Abstract
A simple method and closed-form analytic formulas for symmetric CPS based on single layer substrate (infinite and finite thickness) and multilayer lossy dielectric (semiconductor) substrate, where the permittivity of the superstrate layers decrease away from the strips, are proposed. Since the line models are given analytically, the dependencies of the line parameters may be analyzed and optimized in wide ranges of sizes, permittivities, and losses (substrate resistivity). In general, the formulas are reversible. The measured line parameters may be used to calculate the permittivity and loss tangent (resistivity) of one of the substrate layers if the parameters of the other layers and strips are known. The method may be easily extended to include larger number of substrate layers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241
“The conformal transformations required for the evaluation of partial conductivities due to different layers are similar to the partial capacitances described in Section II-B [21].”
InfluentialSoft-matter capacitors and inductors for hyperelastic strain sensing and stretchable electronics
Fassler, A., & Majidi, C. (2013) · Smart Materials and Structures · doi:10.1088/0964-1726/22/5/055023 · Cited by 198
“The derivation of (1) can be found in [12, 13].”
BackgroundMiniaturised wireless power transfer systems for neurostimulation: a review
Barbruni, G. L., Ros, P. M., Demarchi, D., Carrara, S., & Ghezzi, D. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038599 · Cited by 161
“CP depends on the thicknesses of the different materials in contact with the coil [32]–[33], such as the metal trace itself, the substrate, the bottom coating, the encapsulation material (top coating) and the external environment (e.”
BackgroundFundamental trade-offs between power and data transfer in inductive links for biomedical implants
Dehghanzadeh, P., Zamani, H., & Mandal, S. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3063376 · Cited by 7
“To optimize the coil geometry, we initially used MATLAB (Mathworks, Natick, MA) to optimize the geometry of a closed-form coil model [24], [25].”
Method
Metadata
- Authors
- Gevorgian, S., Berg, H., Jacobsson, H., & Lewin, T.
- Venue
- IEEE Microwave Magazine
- Published
- 2003-06
- Volume
- 4
- Issue
- 2
- Pages
- 60-70
- ISSN
- 1527-3342 (ISSN-L)
- OpenAlex
- W2149880430
- Cited by
- 66
- References
- 0
- FWCI
- 2.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Basic parameters of coplanar-strip waveguides on multilayer dielectric/semiconductor substrates, part 1: high permittivity superstrates. https://app.cochat.ai/papers/10.1109/mmw.2003.1201599
- The paper
- Gevorgian, S., Berg, H., Jacobsson, H., & Lewin, T. (2003). Basic parameters of coplanar-strip waveguides on multilayer dielectric/semiconductor substrates, part 1: high permittivity superstrates. IEEE Microwave Magazine. https://doi.org/10.1109/mmw.2003.1201599
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.