Theoretical and Experimental Analyses of Photovoltaic Systems with Voltage and Current-Based Maximum Power Point Tracking
Abstract
Detailed theoretical and experimental analyses are presented for the comparison of two simple fast and reliable maximum power point tracking (MPPT) techniques for photovoltaic systems (PV): the voltage-based (VMPPT) and the current-based (CMPPT) approaches. A microprocessor-controlled tracker capable of online voltage and current measurements and programmed with both VMPPT and CMPPT algorithms is constructed. The load of the solar system is either a water pump or a resistance. Simulink facilities are used for simulation and modeling of the novel trackers. The main advantage of this new MPPT, as compared with present trackers, is the elimination of reference (dummy) cells, which results in a more efficient, less expensive, and more reliable PV system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425
A Variable Step Size INC MPPT Method for PV Systems
Liu, F., Duan, S., Liu, F., Liu, B., & Kang, Y. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.920550 · Cited by 1,313
Ishaque, K., Salam, Z., Amjad, M., & Mekhilef, S. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2185713 · Cited by 1,100
Masoum, M. A. S., Dehbonei, H., & Fuchs, E. F. (2002) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2002.805205 · Cited by 818
Self-citationReza Reisi, A., Hassan Moradi, M., & Jamasb, S. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.11.052 · Cited by 690
Alajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2090903 · Cited by 635
Topology Study of Photovoltaic Interface for Maximum Power Point Tracking
Xiao, W., Ozog, N., & Dunford, W. G. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.894732 · Cited by 602
A comprehensive review on solar PV maximum power point tracking techniques
Ram, J. P., Babu, T. S., & Rajasekar, N. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.076 · Cited by 511
Adaptive perturb and observe algorithm for photovoltaic maximum power point tracking
Piegari, L., & Rizzo, R. (2010) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2009.0006 · Cited by 435
Nejabatkhah, F., Danyali, S., Hosseini, S. H., Sabahi, M., & Niapour, S. M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2172465 · Cited by 406
A Maximum Power Point Tracking Technique for Partially Shaded Photovoltaic Systems in Microgrids
Alajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2168796 · Cited by 404
A comprehensive review of maximum power point tracking algorithms for photovoltaic systems
Kamarzaman, N. A., & Tan, C. W. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.045 · Cited by 364
Uzunoglu, M., Onar, O. C., & Alam, M. S. (2009) · Renewable Energy · doi:10.1016/j.renene.2008.06.009 · Cited by 341
Raghavendra, K. V. G., Zeb, K., Muthusamy, A., Krishna, T. N. V., Kumar, S. V. S. V. P., Kim, D.-H., Kim, M.-S., Cho, H.-G., & Kim, H.-J. (2019) · Electronics · doi:10.3390/electronics9010031 · Cited by 269
Dehbonei, H., Lee, S. R., & Nehrir, H. (2009) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.2009.4805261 · Cited by 53
Metadata
- Authors
- Masoum, M. A., Dehbonei, H., & Fuchs, E. F.
- Venue
- IEEE Power Engineering Review
- Published
- 2002-08
- Volume
- 22
- Issue
- 8
- Pages
- 62-62
- ISSN
- 0272-1724 (ISSN-L)
- 1558-1705
- OpenAlex
- W3148958314
- Cited by
- 476
- References
- 0
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.