Cardiovascular Monitoring Using Earphones and a Mobile Device
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Many wearable biosensors have failed to be adopted outside of a lab setting or to gain popular acceptance. The Heartphones project seeks to address this by integrating physiological sensing capabilities into a platform already accepted for everyday use, exploiting sensor-embedded earphones and a smartphone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adaptive noise cancelling: Principles and applications
Widrow, B., Glover, J. R., McCool, J. M., Kaunitz, J., Williams, C. S., Hearn, R. H., Zeidler, J. R., Eugene Dong, Jr., & Goodlin, R. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.10036 · Cited by 3,939 · cited 1×
“Under such conditions, motion-artifact removal techniques such as adaptive noise cancellation [9] can be applied to improve performance by incorporating accelerometers into the earbuds.”
MethodGil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461
Cited by
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912
“Year published 2009 [20] 2008 [26] 2007 [19] 2009 [27] 2010 [22] 2012 [24] 2004 [23] 2009 [21]”
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Tapprints: your finger taps have fingerprints
Miluzzo, E., Varshavsky, A., Balakrishnan, S., & Choudhury, R. R. (2012) · Proceedings of the 10th international conference on Mobile systems, applications, and services · doi:10.1145/2307636.2307666 · Cited by 278
Energy Harvesting For Wearable Devices: A Review
Chong, Y.-W., Ismail, W., Ko, K., & Lee, C.-Y. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2925638 · Cited by 263
Current progress of photoplethysmography and SPO2 for health monitoring
Tamura, T. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-019-00097-w · Cited by 247
Zeagler, C. (2017) · Proceedings of the 2017 ACM International Symposium on Wearable Computers · doi:10.1145/3123021.3123042 · Cited by 198
The Effect of Optical Crosstalk on Accuracy of Reflectance-Type Pulse Oximeter for Mobile Healthcare
Baek, H. J., Shin, J., & Cho, J. (2018) · Journal of Healthcare Engineering · doi:10.1155/2018/3521738 · Cited by 22
Metadata
- Authors
- Poh, M.-Z., Kim, K., Goessling, A., Swenson, N., & Picard, R.
- Venue
- IEEE Pervasive Computing
- Published
- 2012-10
- Volume
- 11
- Issue
- 4
- Pages
- 18-26
- ISSN
- 1536-1268 (ISSN-L)
- OpenAlex
- W2014248633
- Cited by
- 92
- References
- 2
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.