The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
The In-the-Ear Recording Concept: User-Centered and Wearable Brain Monitoring
Abstract
The integration of brain monitoring based on electroencephalography (EEG) into everyday life has been hindered by the limited portability and long setup time of current wearable systems as well as by the invasiveness of implanted systems (e.g. intracranial EEG). We explore the potential to record EEG in the ear canal, leading to a discreet, unobtrusive, and user-centered approach to brain monitoring. The in-the-ear EEG (Ear-EEG) recording concept is tested using several standard EEG paradigms, benchmarked against standard onscalp EEG, and its feasibility proven. Such a system promises a number of advantages, including fixed electrode positions, user comfort, robustness to electromagnetic interference, feedback to the user, and ease of use. The Ear-EEG platform could also support additional biosensors, extending its reach beyond EEG to provide a powerful health-monitoring system for those applications that require long recording periods in a natural environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wearable Electroencephalography
Casson, A., Yates, D., Smith, S., Duncan, J., & Rodriguez-Villegas, E. (2010) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2010.936545 · Cited by 404
Evaluation of a fall detector based on accelerometers: A pilot study
Lindemann, U., Hock, A., Stuber, M., Keck, W., & Becker, C. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351026 · Cited by 292
Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography
Poh, M.-Z., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2042607 · Cited by 189
New horizons in ambulatory electroencephalography
Waterhouse, E. J. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213629 · Cited by 129
Neural Network Analysis of the Mastoid EEG for the Assessment of Vigilance
Duta, M. D., Alford, C., Wilson, S. G., & Tarassenko, L. (2004) · International Journal of Human-Computer Interaction · doi:10.1207/s15327590ijhc1702_4 · Cited by 57
Cited by
Phan, H., Andreotti, F., Cooray, N., Chen, O. Y., & De Vos, M. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896659 · Cited by 623
Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear
Debener, S., Emkes, R., De Vos, M., & Bleichner, M. (2015) · Scientific Reports · doi:10.1038/srep16743 · Cited by 382
Casson, A. J. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-018-00093-6 · Cited by 340
Wearable, Wireless EEG Solutions in Daily Life Applications: What are we Missing?
Mihajlovic, V., Grundlehner, B., Vullers, R., & Penders, J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328317 · Cited by 289
Hearables: Automatic Overnight Sleep Monitoring With Standardized In-Ear EEG Sensor
Nakamura, T., Alqurashi, Y. D., Morrell, M. J., & Mandic, D. P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2911423 · Cited by 147
Self-citation
Metadata
- Authors
- Looney, D., Kidmose, P., Park, C., Ungstrup, M., Rank, M., Rosenkranz, K., & Mandic, D.
- Venue
- IEEE Pulse
- Published
- 2012-11
- Volume
- 3
- Issue
- 6
- Pages
- 32-42
- ISSN
- 2154-2287 (ISSN-L)
- OpenAlex
- W2066227468
- Cited by
- 255
- References
- 5
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The In-the-Ear Recording Concept: User-Centered and Wearable Brain Monitoring. https://app.cochat.ai/papers/10.1109/mpul.2012.2216717
- The paper
- Looney, D., Kidmose, P., Park, C., Ungstrup, M., Rank, M., Rosenkranz, K., & Mandic, D. (2012). The In-the-Ear Recording Concept: User-Centered and Wearable Brain Monitoring. IEEE Pulse. https://doi.org/10.1109/mpul.2012.2216717
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.