The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Compliant actuator designs
Abstract
In the growing fields of wearable robotics, rehabilitation robotics, prosthetics, and walking k robots, variable stiffness actuators (VSAs) or adjustable compliant actuators are being designed and implemented because of their ability to minimize large forces due to shocks, to safely interact with the user, and their ability to store and release energy in passive elastic elements. This review article describes the state of the art in the design of actuators with adaptable passive compliance. This new type of actuator is not preferred for classical position-controlled applications such as pick and place operations but is preferred in novel robots where safe human- robot interaction is required or in applications where energy efficiency must be increased by adapting the actuator's resonance frequency. The working principles of the different existing designs are explained and compared. The designs are divided into four groups: equilibrium-controlled stiffness, antagonistic-controlled stiffness, structure-controlled stiffness (SCS), and mechanically controlled stiffness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pratt, G. A., & Williamson, M. M. (2002) · Proceedings 1995 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human Robot Interaction and Cooperative Robots · doi:10.1109/iros.1995.525827 · Cited by 2,206
Efficient Bipedal Robots Based on Passive-Dynamic Walkers
Collins, S., Ruina, A., Tedrake, R., & Wisse, M. (2005) · Science · doi:10.1126/science.1107799 · Cited by 1,873
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589 · cited 1×
“The McKibben muscle [33] is the most well-known design.”
BackgroundDesign and Evaluation of the LOPES Exoskeleton Robot for Interactive Gait Rehabilitation
Veneman, J. F., Kruidhof, R., Hekman, E. E. G., Ekkelenkamp, R., Van Asseldonk, E. H. F., & van der Kooij, H. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903919 · Cited by 1,280
Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait
Blaya, J. A., & Herr, H. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.823266 · Cited by 741
Bicchi, A., & Tonietti, G. (2004) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2004.1310939 · Cited by 654
Tonietti, G., Schiavi, R., & Bicchi, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570172 · Cited by 539
Robotic Orthosis Lokomat: a rehabilitation and research tool
Jezernik, S., Colombo, G., Keller, T., Frueh, H., & Morari, M. (2003) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2003.03017.x · Cited by 503 · cited 1×
“Therefore, robots that can assist in the rehabilitation process are being proposed, e.g., Lokomat [6] and Autoambulator, which impose gaitlike motion patterns to the legs of a patient.”
BackgroundZinn, M., Khatib, O., Roth, B., & Salisbury, J. K. (2004) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2004.1310938 · Cited by 409
Three Uses for Springs in Legged Locomotion
Alexander, R. M. (1990) · The International Journal of Robotics Research · doi:10.1177/027836499000900205 · Cited by 407
Biologically Inspired Joint Stiffness Control
Migliore, S. A., Brown, E. A., & DeWeerth, S. P. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570814 · Cited by 291
Cartesian impedance control of redundant robots: recent results with the DLR-light-weight-arms
Albu-Schaffer, A., Ott, C., Frese, U., & Hirzinger, G. (2004) · 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422) · doi:10.1109/robot.2003.1242165 · Cited by 274
Gravity-Balancing Leg Orthosis and Its Performance Evaluation
Banala, S. K., Agrawal, S. K., Fattah, A., Krishnamoorthy, V., Hsu, W.-L., Scholz, J., & Rudolph, K. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.882928 · Cited by 199
The Actuator With Mechanically Adjustable Series Compliance
Hurst, J. W., Chestnutt, J. E., & Rizzi, A. A. (2010) · IEEE Transactions on Robotics · doi:10.1109/tro.2010.2052398 · Cited by 197
Biomechanical Design of a Powered Ankle-Foot Prosthesis
Au, S. K., Weber, J., & Herr, H. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428441 · Cited by 196
Design of a therapeutic robotic companion for relational, affective touch
Stiehl, W. D., Lieberman, J., Breazeal, C., Basel, L., Lalla, L., & Wolf, M. (2006) · ROMAN 2005. IEEE International Workshop on Robot and Human Interactive Communication, 2005. · doi:10.1109/roman.2005.1513813 · Cited by 188
Powered Ankle-Foot Prosthesis for the Improvement of Amputee Ambulation
Au, S. K., Herr, H., Weber, J., & Martinez-Villalpando, E. C. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4352965 · Cited by 182
An Efficient Robotic Tendon for Gait Assistance
Hollander, K. W., Ilg, R., Sugar, T. G., & Herring, D. E. (2006) · Journal of Biomechanical Engineering · doi:10.1115/1.2264391 · Cited by 161
Self-citationDesign and development of a new robot joint using a mechanical impedance adjuster
Morita, T., & Sugano, S. (2002) · Proceedings of 1995 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1995.525630 · Cited by 159
Mechanics and stiffness limitations of a variable stiffness actuator for use in prosthetic limbs
English, C. E., & Russell, D. (1999) · Mechanism and Machine Theory · doi:10.1016/s0094-114x(98)00026-3 · Cited by 106
Hitt, J. K., Bellman, R. D., Holgate, M. A., Sugar, T. G., & Hollander, K. W. (2007) · doi:10.1115/detc2007-34512 · Cited by 78
Self-citationAn exoskeleton for gait rehabilitation: Prototype design and control principle
Beyl, P., Damme, M. V., Ham, R. V., Versluys, R., Vanderborght, B., & Lefeber, D. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543506 · Cited by 54
Self-citationMARIONET: An exotendon-driven rotary series elastic actuator for exerting joint torque
Sulzer, J. S., Peshkin, M. A., & Patton, J. L. (2005) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2005.1501062 · Cited by 50
ANTY: the development of an intelligent huggable robot for hospitalized children
Saldien, J., Goris, K., Vanderborght, B., Verrelst, B., Ham, R. V., & Lefeber, D. (2006) · Ghent University Academic Bibliography (Ghent University) · Cited by 32
Self-citationStiffness and Angle Control of Antagonistially driven joint
Koganezawa, K., Inaba, T., & Nakazawa, T. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639223 · Cited by 29
FlexCVA: A Continuously Variable Actuator for Active Orthotics
Horst, R. W., & Marcus, R. R. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259950 · Cited by 17
Cited by
Variable impedance actuators: A review
Vanderborght, B., Albu-Schaeffer, A., Bicchi, A., Burdet, E., Caldwell, D. G., Carloni, R., Catalano, M., Eiberger, O., Friedl, W., Ganesh, G., et al. (2013) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2013.06.009 · Cited by 1,008
Self-citationStiffening in Soft Robotics: A Review of the State of the Art
Manti, M., Cacucciolo, V., & Cianchetti, M. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2016.2582718 · Cited by 637
Working Together: A Review on Safe Human-Robot Collaboration in Industrial Environments
Robla-Gomez, S., Becerra, V. M., Llata, J. R., Gonzalez-Sarabia, E., Torre-Ferrero, C., & Perez-Oria, J. (2017) · IEEE Access · doi:10.1109/access.2017.2773127 · Cited by 589
“[30], [49]), can be considered equivalent to the concept of compliant actuator [50], [51].”
BackgroundA Survey of Methods for Safe Human-Robot Interaction
Lasota, P. A., Fong, T., & Shah, J. A. (2017) · Foundations and Trends® in Robotics · doi:10.1561/2300000052 · Cited by 403
Robotic Artificial Muscles: Current Progress and Future Perspectives
Zhang, J., Sheng, J., O'Neill, C. T., Walsh, C. J., Wood, R. J., Ryu, J.-H., Desai, J. P., & Yip, M. C. (2019) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2894371 · Cited by 398
Metadata
- Authors
- Ham, R., Sugar, T., Vanderborght, B., Hollander, K., & Lefeber, D.
- Venue
- IEEE Robotics & Automation Magazine
- Published
- 2009-09
- Volume
- 16
- Issue
- 3
- Pages
- 81-94
- ISSN
- 1070-9932 (ISSN-L)
- OpenAlex
- W2169100281
- Cited by
- 834
- References
- 26
- FWCI
- 19.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.