The DOI matches its Crossref record.
Coordinated Data-Injection Attack and Detection in the Smart Grid: A Detailed Look at Enriching Detection Solutions
Abstract
A smart grid improves the efficiency of power grids via the aid of modern communication, signal processing, and control technologies. While smart grid integration enables power grid networks to be smarter, it also increases the risk of cyberattacks due to the strong dependence on the cyberinfrastructure in the overall system. In this article, the coordinated datainjection attack detection problem in the smart grid is considered. Specifically, the data-injection attack model is first introduced and a thorough survey of existing detection methods is then given. Afterward, three important efforts to enrich the detection solution are presented in detail: 1) attacker versus defender dynamics, where possible interactive attack and defense strategies are discussed in the context of secure phasor measurement unit (PMU) placement 2) distributed attack detection and state recovery, where the focus is how to achieve the optimal centralized performance with a distributed approach 3) quickest detection (QD), where the trade off between the detection speed and detection performance is studied. A list of associated key open problems in this area is then presented to conclude this article.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of Internet of Things (IoT) in Electric Power and Energy Systems
Bedi, G., Venayagamoorthy, G. K., Singh, R., Brooks, R. R., & Wang, K.-C. (2018) · IEEE Internet of Things Journal · doi:10.1109/jiot.2018.2802704 · Cited by 755
False Data Injection on State Estimation in Power Systems—Attacks, Impacts, and Defense: A Survey
Deng, R., Xiao, G., Lu, R., Liang, H., & Vasilakos, A. V. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2614396 · Cited by 553
A survey of physics-based attack detection in cyber-physical systems
Giraldo, J., Urbina, D., Cardenas, A., Valente, J., Faisal, M., Ruths, J., Tippenhauer, N. O., Sandberg, H., & Candell, R. (2019) · ACM Computing Surveys · doi:10.1145/3203245 · Cited by 535
Detecting False Data Injection Attacks on Power Grid by Sparse Optimization
Liu, L., Esmalifalak, M., Ding, Q., Emesih, V. A., & Han, Z. (2014) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2284438 · Cited by 446
Self-citationOn False Data-Injection Attacks against Power System State Estimation: Modeling and Countermeasures
Yang, Q., Yang, J., Yu, W., An, D., Zhang, N., & Zhao, W. (2014) · IEEE Transactions on Parallel and Distributed Systems · doi:10.1109/tpds.2013.92 · Cited by 404
Metadata
- Authors
- Cui, S., Han, Z., Kar, S., Kim, T. T., Poor, H. V., & Tajer, A.
- Venue
- IEEE Signal Processing Magazine
- Published
- 2012-09
- Volume
- 29
- Issue
- 5
- Pages
- 106-115
- ISSN
- 1053-5888 (ISSN-L)
- OpenAlex
- W2071992589
- Cited by
- 229
- References
- 0
- FWCI
- 19.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coordinated Data-Injection Attack and Detection in the Smart Grid: A Detailed Look at Enriching Detection Solutions. https://app.cochat.ai/papers/10.1109/msp.2012.2185911
- The paper
- Cui, S., Han, Z., Kar, S., Kim, T. T., Poor, H. V., & Tajer, A. (2012). Coordinated Data-Injection Attack and Detection in the Smart Grid: A Detailed Look at Enriching Detection Solutions. IEEE Signal Processing Magazine. https://doi.org/10.1109/msp.2012.2185911
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.