The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Detecting False Data Injection Attacks on Power Grid by Sparse Optimization
Abstract
State estimation in electric power grid is vulnerable to false data injection attacks, and diagnosing such kind of malicious attacks has significant impacts on ensuring reliable operations for power systems. In this paper, the false data detection problem is viewed as a matrix separation problem. By noticing the intrinsic low dimensionality of temporal measurements of power grid states as well as the sparse nature of false data injection attacks, a novel false data detection mechanism is proposed based on the separation of nominal power grid states and anomalies. Two methods, the nuclear norm minimization and low rank matrix factorization, are presented to solve this problem. It is shown that proposed methods are able to identify proper power system operation states as well as detect the malicious attacks, even under the situation that collected measurement data is incomplete. Numerical simulation results both on the synthetic and real data validate the effectiveness of the proposed mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bertsekas, D. P. (1997) · Journal of the Operational Research Society · doi:10.1038/sj.jors.2600425 · Cited by 11,726
Robust principal component analysis?
Candès, E. J., Li, X., Ma, Y., & Wright, J. (2011) · Journal of the ACM · doi:10.1145/1970392.1970395 · Cited by 6,921
Zimmerman, R. D., Murillo-Sanchez, C. E., & Thomas, R. J. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2051168 · Cited by 6,756
A Singular Value Thresholding Algorithm for Matrix Completion
Cai, J.-F., Candès, E. J., & Shen, Z. (2010) · SIAM Journal on Optimization · doi:10.1137/080738970 · Cited by 5,809
Constrained Optimization and Lagrange Multiplier Methods
(1982) · Elsevier eBooks · doi:10.1016/c2013-0-10366-2 · Cited by 4,016
Abur, A., & Expósito, A. G. (2004) · CRC Press eBooks · doi:10.1201/9780203913673 · Cited by 2,974
Grainger, J. J., & Stevenson, W. D. (1994) · Cited by 2,754
False data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2011) · ACM Transactions on Information and System Security · doi:10.1145/1952982.1952995 · Cited by 2,428
Kuybeda, O., Frank, G. A., Bartesaghi, A., Borgnia, M., Subramaniam, S., & Sapiro, G. (2013) · Journal of Structural Biology · doi:10.1016/j.jsb.2012.10.010 · Cited by 2,162
Parlar, M. (2000) · Interactive Operations Research with Maple · doi:10.1007/978-1-4612-1356-7_5 · Cited by 1,741
Cited by
A Review of False Data Injection Attacks Against Modern Power Systems
Liang, G., Zhao, J., Luo, F., Weller, S. R., & Dong, Z. Y. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2495133 · Cited by 1,028
A survey on security control and attack detection for industrial cyber-physical systems
Ding, D., Han, Q.-L., Xiang, Y., Ge, X., & Zhang, X.-M. (2018) · Neurocomputing · doi:10.1016/j.neucom.2017.10.009 · Cited by 944
He, Y., Mendis, G. J., & Wei, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2703842 · Cited by 834
A Survey on the Detection Algorithms for False Data Injection Attacks in Smart Grids
Musleh, A. S., Chen, G., & Dong, Z. Y. (2020) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2949998 · Cited by 714
Ghiasi, M., Niknam, T., Wang, Z., Mehrandezh, M., Dehghani, M., & Ghadimi, N. (2023) · Electric Power Systems Research · doi:10.1016/j.epsr.2022.108975 · Cited by 494
Metadata
- Authors
- Liu, L., Esmalifalak, M., Ding, Q., Emesih, V. A., & Han, Z.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2014-03
- Volume
- 5
- Issue
- 2
- Pages
- 612-621
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2012352984
- Cited by
- 446
- References
- 27
- FWCI
- 30.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detecting False Data Injection Attacks on Power Grid by Sparse Optimization. https://app.cochat.ai/papers/10.1109/tsg.2013.2284438
- The paper
- Liu, L., Esmalifalak, M., Ding, Q., Emesih, V. A., & Han, Z. (2014). Detecting False Data Injection Attacks on Power Grid by Sparse Optimization. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2013.2284438
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.