Inciting high fidelity tactile sensations using a single electrotactile electrode pair
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
This paper investigates the possibility of inducing tactile sensations using electrotactile stimulation. The goal is to create several stimulus pattern feeling distinct enough for humans to differentiate them using only a single electrode. A single electrode is considered so that maximum fidelity of sensation can be achieved on parts of human skin with low receptor density in the dermis layer such as the forearm or abdomen. Two experiments were conducted on eight participants using a custom electrotactile waveform generator, a stimulation circuit, and electrodes. Experiment 1 investigates the possibility of quantifying different sensations induced by an electrotactile electrode. Experiment 2 investigates the ability of humans in identifying a number of different waveforms being sequentially played through a single electrotactile electrode pair. A confusion matrix was formed to analyze the ability of humans in distinguishing different waveforms. The results show an average sensitivity of 93%, specificity of 92%, precision of 98%, and accuracy of 94%. These results demonstrate that it is possible to produce distinguishable sensations using a single electrotactile electrode pair and electrotactile stimulation in general.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Alternatively, electro-tactile (ET) devices are advantageous due to its small size, light weight, and high resolution (9–12).”
From Self-powered electro-tactile system for virtual tactile experiences (2021) · cites this paper as [11]
Citations
Cites
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827 · cited 1×
“current flow through a small low resistance region (probably sweat ducts, sebaceous glands, and minute epithelial breaks, 1-6 per mm2 skin area) will result in a painful sensation [12].”
BackgroundStrong, R., & Troxel, D. (1970) · IEEE Transactions on Man Machine Systems · doi:10.1109/tmms.1970.299965 · Cited by 146 · cited 1×
“Numerous research efforts [1] and patents [2] aiming to utilize electrotactile displays have been produced as early as mid-20 century for in-demand applications such as sensory substitution for sight [3], feedback for prosthetics [4][5], sensory enhancement for VR/AR [6], and tactile feedback for touch panels [7], etc.”
BackgroundYem, V., & Kajimoto, H. (2017) · 2017 IEEE Virtual Reality (VR) · doi:10.1109/vr.2017.7892236 · Cited by 122 · cited 2×
“I. INTRODUCTION Numerous research efforts [1] and patents [2] aiming to utilize electrotactile displays have been produced as early as mid-20th century for in-demand applications such as sensory substitution for sight [3], feedback for prosthetics [4][5], sensory enhancement for VR/AR [6], and tactile feedback for tou…”
BackgroundSolomonow, M., Lyman, J., & Freedy, A. (1977) · Annals of Biomedical Engineering · doi:10.1007/bf02409338 · Cited by 108 · cited 1×
“The TPD for fingertips is almost four times smaller than that of forearms [10].”
BackgroundIntegrated and flexible multichannel interface for electrotactile stimulation
Štrbac, M., Belić, M., Isaković, M., Kojić, V., Bijelić, G., Popović, I., Radotić, M., Došen, S., Marković, M., Farina, D., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046014 · Cited by 106
Forehead Electro-tactile Display for Vision Substitution
Kajimoto, H. (2006) · Cited by 89
Franceschi, M., Seminara, L., Dosen, S., Strbac, M., Valle, M., & Farina, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2016.2618377 · Cited by 75 · cited 1×
“Hence, it is imperative to focus on achieving maximum sensations using a single electrode pair on lower TPD of unobtrusive skin locations, rather than using a large array of electrodes as presented in [11]-[8].”
BackgroundElectro-tactile device for material texture simulation
Germani, M., Mengoni, M., & Peruzzini, M. (2013) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-013-4832-1 · Cited by 53 · cited 1×
“Hence, it is imperative to focus on achieving maximum sensations using a single electrode pair on lower TPD of unobtrusive skin locations, rather than using a large array of electrodes as presented in [11]-[8].”
BackgroundA 16-channel 8-parameter waveform electrotactile stimulation system
Kaczmarek, K. A., Kramer, K. M., Webster, J. G., & Radwin, R. G. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.88439 · Cited by 47 · cited 2×
“The isolation capacitances limit the total charge transferred to the skin in case of transistor and fuse failures as described in [13].”
BackgroundGeng, B., Dong, J. C., Jensen, W., Dosen, S. S., Farina, D., & Kamavuako, E. N. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2803844 · Cited by 45 · cited 1×
“Numerous research efforts [1] and patents [2] aiming to utilize electrotactile displays have been produced as early as mid-20 century for in-demand applications such as sensory substitution for sight [3], feedback for prosthetics [4][5], sensory enhancement for VR/AR [6], and tactile feedback for touch panels [7], etc.”
Background
Research works printed but not linked: 1
- watanabe, 1953, USC. 154 (b) by 0 days. FOREIGN PATENT DOCUMENTS, Science (80- ), 118, 277
Cited by
Self-powered electro-tactile system for virtual tactile experiences
Shi, Y., Wang, F., Tian, J., Li, S., Fu, E., Nie, J., Lei, R., Ding, Y., Chen, X., & Wang, Z. L. (2021) · Science Advances · doi:10.1126/sciadv.abe2943 · Cited by 251
Parsnejad, S., Dávila-Montero, S., & Mason, A. J. (2020) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas45731.2020.9180797 · Cited by 12
Self-citationElectrotactile displays: taxonomy, cross-modality, psychophysics and challenges
Ray, R. K., Vasudevan, M. K., & Manivannan, M. (2024) · Frontiers in Virtual Reality · doi:10.3389/frvir.2024.1406923 · Cited by 11
Xiong, Q., Yao, H., Wang, J., Huang, Z., Luo, J., Zhong, C., Lin, Y., & Shu, L. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1519758 · Cited by 7
“Parsnejad et al. (2019) investigated the qualitative effects of different waveforms on different sensory qualities using coplanar electrodes, as shown in Figure 9c, different waveforms will lead to different perceptual quality in different perceptual forms.”
A Comprehensive Survey of Electrical Stimulation Haptic Feedback in Human-Computer InteractionPreprint
Yang, S., Wang, X., Li, Y., Lee, L., Braud, T., & Hui, P. (2025) · arXiv (Cornell University) · doi:10.48550/arxiv.2504.21477 · Cited by 7
“Additionally, they examine how electrotactile stimulation can induce diverse perceptual experiences, such as temperature perception [55], roughness [123], [132], softness [137], and multimodal sensations [57], [86], [114], [130].”
Metadata
- Authors
- Parsnejad, S., Gtat, Y., Aridi, R., Brascamp, J. W., & Mason, A. J.
- Affiliations
- Michigan State University (US)
- Venue
- 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER)
- Publisher
- IEEE
- Published
- 2019-03
- Pages
- 778-781
- ISSN
- 1948-3554 (ISSN-L)
- OpenAlex
- W2946151171
- Cited by
- 10
- References
- 12
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 1 · 2022: 1 · 2021: 2 · 2020: 2 · 2019: 1
- FWCI
- 2.59
- Type
- conference paper
- Language
- en
- Open access
- closed
- Licence
- Locations
- International IEEE/EMBS Conference on Neural Engineering (publishedVersion)
- Funders
- National Institutes of Health
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- electrocutaneous stimulation, tactile perception, tactile feedback, waveform discrimination
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.