Wearable tactile device using mechanical and electrical stimulation for fingertip interaction with virtual world
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We developed “Finger Glove for Augmented Reality” (FinGAR), which combines electrical and mechanical stimulation to selectively stimulate skin sensory mechanoreceptors and provide tactile feedback of virtual objects. A DC motor provides high-frequency vibration and shear deformation to the whole finger, and an array of electrodes provide pressure and low-frequency vibration with high spatial resolution. FinGAR devices are attached to the thumb, index finger and middle finger. It is lightweight, simple in mechanism, easy to wear, and does not disturb the natural movements of the hand. All of these attributes are necessary for a general-purpose virtual reality system. User study was conducted to evaluate its ability to reproduce sensations of four tactile dimensions: macro roughness, friction, fine roughness and hardness. Result indicated that skin deformation and cathodic stimulation affect macro roughness and hardness, whereas high-frequency vibration and anodic stimulation affect friction and fine roughness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jones, L. A., & Lederman, S. J. (2006) · doi:10.1093/acprof:oso/9780195173154.001.0001 · Cited by 720
Modeling axon membranes for functional electrical stimulation
Rattay, F., & Aberham, M. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250575 · Cited by 174
Cited by
Whitmire, E., Benko, H., Holz, C., Ofek, E., & Sinclair, M. (2018) · Proceedings of the 2018 CHI Conference on Human Factors in Computing Systems · doi:10.1145/3173574.3173660 · Cited by 264
Smart Infrastructure: A Vision for the Role of the Civil Engineering Profession in Smart Cities
Berglund, E. Z., Monroe, J. G., Ahmed, I., Noghabaei, M., Do, J., Pesantez, J. E., Khaksar Fasaee, M. A., Bardaka, E., Han, K., Proestos, G. T., et al. (2020) · Journal of Infrastructure Systems · doi:10.1061/(asce)is.1943-555x.0000549 · Cited by 185
Yem, V., Vu, K., Kon, Y., & Kajimoto, H. (2018) · 2018 IEEE Conference on Virtual Reality and 3D User Interfaces (VR) · doi:10.1109/vr.2018.8446403 · Cited by 47
Self-citationInciting high fidelity tactile sensations using a single electrotactile electrode pair
Parsnejad, S., Gtat, Y., Aridi, R., Brascamp, J. W., & Mason, A. J. (2019) · 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER) · doi:10.1109/ner.2019.8717131 · Cited by 10
Metadata
- Authors
- Yem, V., & Kajimoto, H.
- Venue
- 2017 IEEE Virtual Reality (VR)
- Publisher
- IEEE
- Published
- 2017
- Pages
- 99-104
- OpenAlex
- W2604884515
- Cited by
- 122
- References
- 2
- FWCI
- 18.54
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wearable tactile device using mechanical and electrical stimulation for fingertip interaction with virtual world. https://app.cochat.ai/papers/10.1109/vr.2017.7892236
- The paper
- Yem, V., & Kajimoto, H. (2017). Wearable tactile device using mechanical and electrical stimulation for fingertip interaction with virtual world. 2017 IEEE Virtual Reality (VR). https://doi.org/10.1109/vr.2017.7892236
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.