Spatiotemporal Imaging with Partially Separable Functions
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Spatiotemporal imaging has a wide range of applications from functional neuroimaging, cardiac imaging to metabolic cancer imaging. A long-standing practical problem lies in obtaining high spatiotemporal resolution because the amount of data required increases exponentially as the physical dimension increases. This paper describes a new way for spatiotemporal imaging using partially separable functions. This model admits highly sparse sampling of the data space, providing a novel, effective way to achieve high spatiotemporal resolution. Practical imaging data will also be presented to demonstrate the performance of the new method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Optimally sparse representation in general (nonorthogonal) dictionaries via ℓ 1 minimization
Donoho, D. L., & Elad, M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0437847100 · Cited by 2,898
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Cited by
Demene, C., Deffieux, T., Pernot, M., Osmanski, B.-F., Biran, V., Gennisson, J.-L., Sieu, L.-A., Bergel, A., Franqui, S., Correas, J.-M., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2428634 · Cited by 983
Accelerating magnetic resonance imaging via deep learning
Wang, S., Su, Z., Ying, L., Peng, X., Zhu, S., Liang, F., Feng, D., & Liang, D. (2016) · 2016 IEEE 13th International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493320 · Cited by 800
Accelerated Dynamic MRI Exploiting Sparsity and Low-Rank Structure: k-t SLR
Lingala, S. G., Hu, Y., DiBella, E., & Jacob, M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2100850 · Cited by 664
Sparse Bayesian Methods for Low-Rank Matrix Estimation
Babacan, S. D., Luessi, M., Molina, R., & Katsaggelos, A. K. (2012) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2012.2197748 · Cited by 327
Haldar, J. P. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2293974 · Cited by 326
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Christodoulou, A. G., Shaw, J. L., Nguyen, C., Yang, Q., Xie, Y., Wang, N., & Li, D. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0217-y · Cited by 323
Compressed sensing for body MRI
Feng, L., Benkert, T., Block, K. T., Sodickson, D. K., Otazo, R., & Chandarana, H. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25547 · Cited by 306
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Self-citationImage Reconstruction: From Sparsity to Data-Adaptive Methods and Machine Learning
Ravishankar, S., Ye, J. C., & Fessler, J. A. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2936204 · Cited by 294
k‐t PCA: Temporally constrained k‐t BLAST reconstruction using principal component analysis
Pedersen, H., Kozerke, S., Ringgaard, S., Nehrke, K., & Kim, W. Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22052 · Cited by 294
ADMiRA: Atomic Decomposition for Minimum Rank Approximation
Lee, K., & Bresler, Y. (2010) · IEEE Transactions on Information Theory · doi:10.1109/tit.2010.2054251 · Cited by 267
Unbiased Risk Estimates for Singular Value Thresholding and Spectral Estimators
Candes, E. J., Sing-Long, C. A., & Trzasko, J. D. (2013) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2013.2270464 · Cited by 243
“Singular value thresholding, Stein’s unbiased risk estimate (SURE), differentiability of eigenvalues and eigenvectors, magnetic resonance cardiac imaging.”
BackgroundBlind Compressive Sensing Dynamic MRI
Lingala, S. G., & Jacob, M. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2255133 · Cited by 237
“The model in (3) can also be expressed as the partially separable function (PSF) model [10], [15]”
InfluentialHighly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE
Feng, L., Srichai, M. B., Lim, R. P., Harrison, A., King, W., Adluru, G., Dibella, E. V. R., Sodickson, D. K., Otazo, R., & Kim, D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24440 · Cited by 232
“One such method is the partially separable function model (25), which has been shown to produce high spatio-temporal resolution for imaging rat hearts (26).”
Low-Rank Modeling and Its Applications in Image Analysis
Zhou, X., Yang, C., Zhao, H., & Yu, W. (2015) · ACM Computing Surveys · doi:10.1145/2674559 · Cited by 174
“For example, u ℓ ( k ) and v ℓ ( t ) for ℓ = 1 , · · · , L can be obtained by fully sampling L columns and rows of the ( k , t ) -space [Liang 2007].”
BackgroundMethod
Metadata
- Authors
- Liang, Z.-P.
- Venue
- 2007 Joint Meeting of the 6th International Symposium on Noninvasive Functional Source Imaging of the Brain and Heart and the International Conference on Functional Biomedical Imaging
- Publisher
- IEEE
- Published
- 2007-10
- Pages
- 181-182
- OpenAlex
- W1999795676
- Cited by
- 204
- References
- 4
- FWCI
- 12.98
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.