A smart cushion based on SFS (single-mode-few-mode-single-mode) structure is proposed and experimentally demonstrated, which can be applied in physiological and activity states monitoring simultaneously. The sensing unit embedded in a common cushion is designed as a sandwich structure, consisting of a piece of fiberglass mesh, a SFS structure layer and a polyvinyl chloride (PVC) layer thus the sensitivity can be significantly enhanced. With off-line processing and analyzing of the raw signals collected from the cushion system, the heartbeat rate (HR) and respiratory rate (RR) can be obtained with the maximum error of 1 bpm and the activity states on the cushion can be clearly distinguished within the accuracy of one second. Such a smart cushion has the advantages of low cost, compact structure and high comfort, especially suitable for office workers and the elderly in nursing homes.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/oecc48412.2020.9273653

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • An SFS-based smart cushion with a fiberglass mesh/SFS/PVC sandwich structure can achieve a maximum error of 1 bpm.

    “Furthermore, it is a smart cushion based on the SFS (single-mode-few-mode-single-mode) structure [221], where the sensing unit is a sandwich structure consisting of a piece of fiberglass mesh, an SFS structure layer, and a PVC layer and can achieve a maximum error of 1 bpm.”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [221]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Han, S., Xu, W., You, S., Dong, B., Tan, F., Yu, C., Zhao, W., & Wang, Y.
Affiliations
  • Soochow University (CN)
  • Chinese Academy of Sciences (CN)
  • Shanxi University (CN)
  • Hong Kong Polytechnic University (HK)
Venue
2020 Opto-Electronics and Communications Conference (OECC)
Publisher
IEEE
Published
2020-10-04
Pages
1-3
OpenAlex
W3110852526
Cited by
2
References
8
Citations by year
2022: 2
FWCI
0.91
Type
conference paper
Language
en
Open access
Locations
  • Opto-Electronics and Communications Conference (OECC) (publishedVersion)
  • PolyU Institutional Research Archive (Hong Kong Polytechnic University) (submittedVersion)
  • Institutional Repository of Xi'an Institute of Optics and Fine Mechanics, Chinese Academy of Sciences (Xian Institute of Optics and Precision Mechanics) (submittedVersion, cc-by-nc-sa)
Funders
National Natural Science Foundation of China
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
Keywords
piezoresistive sensing, physiological monitoring, activity monitoring, respiratory rate measurement, office workers, elderly care

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review