Design considerations for high power high frequency transformers
The DOI matches its Crossref record.
Abstract
Various design considerations for high-power (multikilowatt), high-frequency transformers for DC-DC power converters are investigated. Although Ferrite (PC40) is lossier than Permalloy80 (0.5 mil) at the frequencies of interest (25-50 kHz) the use of the former is justified on the basis of cost, weight, and wide ranges of shapes. The influence of the leakage flux distribution in the window region on the copper losses has been demonstrated for various conventional winding arrangements. However, it is seen that in conventionally wound transformers a considerable amount of leakage flux enters the core, resulting in localized core saturation and hot-spots. This becomes a very critical issue for high-power, high-frequency transformers. Coaxially wound transformers are seen to be a viable alternative, in that the leakage flux is contained with the interwinding space, with very little or none of it permeating the core. Such transformers can also realize multiple benefits of a low distributed and controllable leakage inductance, robust construction, low electromechanical forces, and low core and copper losses. Test results on two coaxially wound transformers with different tube geometries, designed for 50 kW, 50 kHz, primary voltage of 200 V, and secondary voltage of 1000 V (two windings), are presented. Finally the concept of coaxial winding technique for three-phase transformers is also presented.>
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535
Self-citationPerformance characterization of a high-power dual active bridge DC-to-DC converter
Kheraluwala, M. N., Gascoigne, R. W., Divan, D. M., & Baumann, E. D. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175280 · Cited by 1,496
Self-citationHannan, M. A., Ker, P. J., Lipu, M. S. H., Choi, Z. H., Rahman, M. S. A., Muttaqi, K. M., & Blaabjerg, F. (2020) · IEEE Access · doi:10.1109/access.2020.2967345 · Cited by 339
“Design consideration of the HF converters also depends on the types of transformer winding geometry such as solenoidal and coaxial winding [92], [93].”
BackgroundHigh-Power Bidirectional DC–DC Converter for Aerospace Applications
Naayagi, R. T., Forsyth, A. J., & Shuttleworth, R. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2184771 · Cited by 305
“Nevertheless, design considerations for high frequency (HF) DAB converter transformers are primarily concerned with core material selection, loss minimization, and realization of controlled leakage inductances as discussed in [13] and [14].”
BackgroundDesign considerations for high-frequency coaxial winding power transformers
Rauls, M. S., Novotny, D. W., & Divan, D. M. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.216547 · Cited by 56
Self-citation
Metadata
- Authors
- Kheraluwala, M. H., Novotny, D. W., & Divan, D. M.
- Venue
- 21st Annual IEEE Conference on Power Electronics Specialists
- Publisher
- IEEE
- Published
- 2002-12-04
- Pages
- 734-742
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W2544573780
- Cited by
- 84
- References
- 0
- FWCI
- 11.75
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.