The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
New positive-sequence voltage detector for grid synchronization of power converters under faulty grid conditions
Abstract
This paper deals with a fundamental aspect in the control of grid-connected power converters, i.e., the detection of the positive-sequence component at fundamental frequency of the utility voltage under unbalanced and distorted conditions. Accurate and fast detection of this voltage component under grid faults is essential to keep the control over the power exchange with the grid avoiding to trip the converter protections and allowing the ride-through of the transient fault. In this paper, the systematic use of well known techniques conducts to a new positive-sequence voltage detection system which exhibits a fast, precise, and frequency-adaptive response under faulty grid conditions. Three fundamental functional blocks make up the proposed detector, these are: i) the quadrature-signals generator (QSG), ii) the positive-sequence calculator (PSC), and iii) the phase-locked loop (PLL). A key innovation of the proposed system is the use of a dual second order generalized integrator (DSOGI) to implement the QSG. For this reason, the proposed positive-sequence detector is called DSOGI-PLL. A detailed study of the DSOGI-PLL and verification by simulation are performed in this paper. From the obtained results, it can be concluded that the DSOGI-PLL is a very suitable technique for characterizing the positive-sequence voltage under grid faults.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Wiley eBooks · doi:10.1002/0470012684 · Cited by 2,915
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567077 · Cited by 997
Operation of a phase locked loop system under distorted utility conditions
Kaura, V., & Blasko, V. (2002) · Proceedings of Applied Power Electronics Conference. APEC '96 · doi:10.1109/apec.1996.500517 · Cited by 903
Yuan, X., Merk, W., Stemmler, H., & Allmeling, J. (2002) · IEEE Transactions on Industry Applications · doi:10.1109/28.993175 · Cited by 815
Yuan, X., Allmeling, J., Merk, W., & Stemmler, H. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883122 · Cited by 663
Karimi-Ghartemani, M., & Iravani, M. R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.831280 · Cited by 575
Performance evaluation of PLL algorithms for single-phase grid-connected systems
Silva, S. M., Lopes, B. M., Cardoso Filho, B. J., Campana, R. P., & Boaventura, W. C. (2004) · Conference Record of the 2004 IEEE Industry Applications Conference, 2004. 39th IAS Annual Meeting. · doi:10.1109/ias.2004.1348790 · Cited by 343
An adaptive detecting method for harmonic and reactive currents
Luo, S., & Zhencheng, H. (1995) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.345850 · Cited by 152
An adaptive detecting method for harmonic and reactive currents
Luo, S., Zhengcheng, H., & Liang, Z. (2002) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.1993.320651 · Cited by 145
Cited by
Rodriguez, P., Luna, A., Candela, I., Mujal, R., Teodorescu, R., & Blaabjerg, F. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2042420 · Cited by 1,112
Self-citationFlexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.899914 · Cited by 726
Self-citationDong, D., Wen, B., Boroyevich, D., Mattavelli, P., & Xue, Y. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2334665 · Cited by 709
Rodríguez, P., Luna, A., Muñoz-Aguilar, R. S., Etxeberria-Otadui, I., Teodorescu, R., & Blaabjerg, F. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2159242 · Cited by 681
Self-citationGuo, X., Wu, W., & Chen, Z. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2041738 · Cited by 475
Addressing DC Component in PLL and Notch Filter Algorithms
Karimi-Ghartemani, M., Khajehoddin, S. A., Jain, P. K., Bakhshai, A., & Mojiri, M. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2158238 · Cited by 380
Gabe, I. J., Montagner, V. F., & Pinheiro, H. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2016097 · Cited by 354
Gong, Z., Wu, X., Dai, P., & Zhu, R. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2844836 · Cited by 106
Fast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Metadata
- Authors
- Rodríguez, P., Teodorescu, R., Candela, I., Timbus, A. V., Liserre, M., & Blaabjerg, F.
- Venue
- 2006 37th IEEE Power Electronics Specialists Conference
- Publisher
- IEEE
- Published
- 2006-06
- Pages
- 1-7
- ISSN
- 0275-9306 (ISSN-L)
- OpenAlex
- W1737158314
- Cited by
- 842
- References
- 10
- FWCI
- 26.30
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.