Frequency support from modular multilevel converter based multi-terminal HVDC schemes
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Multiterminal HVDC (MTDC) schemes are intended to transfer power from offshore wind farms to land and interconnect the grids of adjacent countries, through Voltage Source Converters (VSC). The modular multilevel converter (MMC) topology of VSCs is a more recent development which has low harmonics, reduced losses and occupies less space. This paper analyses the frequency support characteristics of MMC-based multiterminal HVDC schemes, using the energy transferred from the capacitance of the MMCs, wind turbine rotating mass and other AC systems. A generic formulation of an equivalent synthetic inertia constant is proposed to determine the energy transferred from the MTDC scheme. A 3-terminal MMCHVDC system is utilised to study the influence of cell capacitance of the submodules and the proposed synthetic inertia constant of the MTDC system on the frequency support capability of the MMC capacitors. The time response and energy capability of the different energy sources of the MTDC system are compared.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387 · cited 1×
“Within the internal controls of the MMC, a balancing control algorithm balances capacitor voltages during normal operation [11] and a circulating current suppression control prevents distortion of arm currents [12].”
BackgroundGnanarathna, U. N., Gole, A. M., & Jayasinghe, R. P. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2060737 · Cited by 739
Detailed and Averaged Models for a 401-Level MMC–HVDC System
Peralta, J., Saad, H., Dennetiere, S., Mahseredjian, J., & Nguefeu, S. (2012) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2012.2188911 · Cited by 623
Wind Energy Generation: Modelling and Control
Anaya‐Lara, O., Jenkins, N., Ekanayake, J. B., Cartwright, P., & Hughes, M. (2009) · CERN Document Server (European Organization for Nuclear Research) · Cited by 528
Self-citationInertia Emulation Control Strategy for VSC-HVDC Transmission Systems
Zhu, J., Booth, C. D., Adam, G. P., Roscoe, A. J., & Bright, C. G. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2213101 · Cited by 466
Dynamic Contribution of DFIG-Based Wind Plants to System Frequency Disturbances
Kayikci, M., & Milanovic, J. V. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016062 · Cited by 462
Gautam, D., Goel, L., Ayyanar, R., Vittal, V., & Harbour, T. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2051690 · Cited by 327
Primary Frequency Response From Electric Vehicles in the Great Britain Power System
Mu, Y., Wu, J., Ekanayake, J., Jenkins, N., & Jia, H. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2220867 · Cited by 290
Self-citationSilva, B., Moreira, C. L., Seca, L., Phulpin, Y., & Pecas Lopes, J. A. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2199774 · Cited by 231
Li, Y., Zhang, Z., Yang, Y., Li, Y., Chen, H., & Xu, Z. G. (2014) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.02.003 · Cited by 101
Research works printed but not linked: 2
- 2014, ENTSO-E. Draft Network Code on High Voltage Direct Current Connections and DC-connected Power Park Modules, Brussels Tech Rep
- 2011, National Grid. Grid Code Frequency Response Technical Sub-Group Report, Technical Report
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“frequency control in grids with high penetration of power converters, several grid-forming control algorithms have been adapted to operate together with MMCs [82], [83].”
MethodModular Multilevel Converter Synthetic Inertia-Based Frequency Support for Medium-Voltage Microgrids
Yang, S., Fang, J., Tang, Y. K., Qiu, H., Dong, C., & Wang, P. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2890491 · Cited by 121
Short-Term Frequency Regulation and Inertia Emulation Using an MMC-Based MTDC System
León, A. E. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2757258 · Cited by 101
“support of various energy sources, such as wind farms and MTDC systems [9].”
BackgroundModeling of HVDC Tie Links and Their Utilization in AGC/LFC Operations of Multiarea Power Systems
Pathak, N., Verma, A., Bhatti, T. S., & Nasiruddin, I. (2018) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835387 · Cited by 99
“The same control strategy was also implemented in multiterminal HVdc systems [21], [22].”
MethodZhang, H., Xiang, W., & Wen, J. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3244807 · Cited by 104
Babu, N. R., & Saikia, L. C. (2019) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2018.6089 · Cited by 68
Zhang, H., Xiang, W., He, Y., & Wen, J. (2023) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2023.3239166 · Cited by 59
Babu, N. R., & Saikia, L. C. (2021) · IET Renewable Power Generation · doi:10.1049/rpg2.12093 · Cited by 56
“[22] presented the idea of multi-terminal HVDC links.”
BackgroundImpact on Interarea Modes of Fast HVDC Primary Frequency Control
Harnefors, L., Johansson, N. P., & Zhang, L. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2570432 · Cited by 51
Decentralized model predictive control of voltage source converters for AC frequency containment
Papangelis, L., Debry, M.-S., Prévost, T., Panciatici, P., & Cutsem, T. V. (2017) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.12.015 · Cited by 40
“The same concept was expanded in [10] for MTDC grids with Modular Multilevel Converters (MMC).”
BackgroundAGC of a multiarea system incorporating accurate HVDC and precise wind turbine systems
Babu, N. R., & Saikia, L. C. (2019) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12277 · Cited by 40
Singh, K., & Arya, Y. (2023) · Soft Computing · doi:10.1007/s00500-023-07839-0 · Cited by 39
Exploiting Redundant Energy of MMC–HVDC to Enhance Frequency Response of Low Inertia AC Grid
Kim, H., Kang, J., Shim, J. W., Beerten, J., Hertem, D. V., Jung, H.-J., Kim, C., & Hur, K. (2019) · IEEE Access · doi:10.1109/access.2019.2942852 · Cited by 44
“Inertial and primary frequency support control for multi-terminal HVDC is proposed in [3], [4].”
BackgroundLiu, Z., Lv, X., Wu, F. P., & Li, Z. (2023) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2023.3259039 · Cited by 35
“What’s more, it has been proved in [20] that the time response of the capacitance is faster than the other energy sources such as wind turbine rotating mass and other ac systems.”
BackgroundOperation of a Modular Multilevel Converter Controlled as a Virtual Synchronous Machine
DrArco, S., Guidi, G., & Suul, J. A. (2018) · International Power Electronics Conference (IPEC) · doi:10.23919/ipec.2018.8508009 · Cited by 32
“The first examples of studying the utilization of MMCbased HVDC terminals for providing virtual inertia and frequency support have recently been published in [21], [22], based on numerical simulations.”
BackgroundKhanjanzadeh, A., Soleymani, S., Mozafari, B., & Fotuhi, M. (2020) · Electrical Engineering · doi:10.1007/s00202-020-00944-5 · Cited by 26
Babu, N. R., Bhagat, S. K., Saikia, L. C., & Chiranjeevi, T. (2020) · Journal of Discrete Mathematical Sciences and Cryptography · doi:10.1080/09720529.2020.1728896 · Cited by 26
“Authors in [5, 6] presented the benefits of AC-HVDC tie-lines.”
BackgroundHosseinnataj, S., Gholamian, S. A., Rezanejad, M., & Mehrasa, M. (2023) · IET Renewable Power Generation · doi:10.1049/rpg2.12828 · Cited by 21
Yang, S., Fang, J., Tang, Y. K., Qiu, H., Dong, C., & Wang, P. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8558158 · Cited by 23
“Frequency support in a MMC-based multi-terminal dc transmission network is achieved by adjusting the dc bus voltage of the network in [6].”
BackgroundPower Losses of Advanced MMC Submodule Topologies Using Si- and SiC-Semiconductors
Dahmen, C., & Marquardt, R. (2019) · European Conference on Power Electronics and Applications · doi:10.23919/epe.2019.8915430 · Cited by 20
Impact of grid-forming control on the internal energy of a modular multilevel converter
Rokrok, E., Qoria, T., Bruyere, A., Francois, B., Zhang, H., Belhaouane, M., & Guillaud, X. (2020) · 2020 22nd European Conference on Power Electronics and Applications (EPE'20 ECCE Europe) · doi:10.23919/epe20ecceeurope43536.2020.9215646 · Cited by 19
“The first examples of studying the utilization of the grid-forming control for the MMC have been published in [5], [6] with the aim of providing virtual inertia and frequency support for an MMC-based HVDC terminal.”
BackgroundBabu, N. R., Chiranjeevi, T., Saha, A., & Bhagat, S. K. (2023) · Journal of Engineering Research · doi:10.1016/j.jer.2023.100123 · Cited by 17
An Improved Droop Control Method for Multi-Terminal VSC-HVDC Converter Stations
Wang, H., Wang, Y., Duan, G., Hu, W., Wang, W., & Chen, Z. (2017) · Energies · doi:10.3390/en10070843 · Cited by 16
Babu, N. R., Narrisetty, V., & Saikia, L. C. (2019) · IEEE India Conference · doi:10.1109/indicon47234.2019.9029073 · Cited by 16
“Authors in [5] presented the assistance of parallel AC/DC links.”
BackgroundMethodZhang, H., Wei, K., Wei, Y., & Zhu, H. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2022.108314 · Cited by 12
Babu, N. R., & Saikia, L. C. (2020) · IEEE International Conference on Power Electronics, Smart Grid, and Renewable Energy (PESGRE) · doi:10.1109/pesgre45664.2020.9070654 · Cited by 12
“[5], Rakhshani et al.”
Maiden Application of Hybrid Crow-Search Algorithm with Particle Swarm Optimization in LFC Studies
Babu, N. R., Saikia, L. C., Bhagat, S. K., & Saha, A. (2020) · Advances in intelligent systems and computing · doi:10.1007/978-981-15-4992-2_40 · Cited by 12
Hosseinnataj, S., Mehrasa, M., Rezanejad, M., Gholamian, S. A., Rodrigues, E. M. G., & Melício, R. (2024) · IEEE Mediterranean Electrotechnical Conference (MELECON) · doi:10.1109/melecon56669.2024.10608700 · Cited by 11
“Frequency control can be regarded as one of MMC’s responsibilities in power system applications [26-28].”
BackgroundFast frequency support control in the GB power system using VSC-HVDC technology
Orellana, L., Matilla, V., Wang, S., Adeuyi, O. D., & Ugalde‐Loo, C. E. (2017) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope.2017.8260209 · Cited by 10
Self-citationHaro-Larrode, M., Santos-Mugica, M., Etxegarai, A., & Eguia, P. (2020) · Energies · doi:10.3390/en13112807 · Cited by 9
“For that purpose, in the literature frequency events have been introduced by random load increase or decrease events [15,16,23], random generation loss events for the study of under-frequency response [24,25], or by power system models such as the 3-bus great britain (GB) model and the simplified GB model in [26].”
MethodBhagat, S. K., Saikia, L. C., & Babu, N. R. (2023) · Iranian Journal of Science and Technology Transactions of Electrical Engineering · doi:10.1007/s40998-023-00641-6 · Cited by 8
“This can be achieved by connecting a HVDC link (Adeuyi et al. 2015; Sharma et al. 2016).”
Meseret, G. M., Kumhar, R., Mahato, T. K., Kumar, N., Lakra, P., & Alam, M. (2025) · Engineering Reports · doi:10.1002/eng2.70160 · Cited by 7
Analysis of MTDC Inertia Emulation Impact on Connected AC Systems
Wang, S., Zhang, S., Ma, Y., Wang, F., & Tolbert, L. M. (2018) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557977 · Cited by 7
“The coordinated IE control strategy is used in this paper, which features using both the electric energy stored in dc link capacitors and the energy transferred from the remote grid side based on the variation of the main ac grid frequency [5, 18-20].”
MethodLFC of a Solar Thermal Integrated Thermal System Considering CSO Optimized TI-DN Controller
Babu, N. R., Saikia, L. C., Bhagat, S. K., Ramoji, S. K., Dekaraja, B., & Behera, M. K. (2021) · Smart innovation, systems and technologies · doi:10.1007/978-981-15-9829-6_25 · Cited by 7
Effect of PWTS and AHVDC link on Multi-Area AGC System Considering TIDD Controller
Bhagat, S. K., Saikia, L. C., Meseret, G. M., Behera, M. K., Ramoji, S. K., Babu, N. R., & Dekaraja, B. (2022) · IEEE Silchar Subsection Conference (SILCON) · doi:10.1109/silcon55242.2022.10028942 · Cited by 7
“The conventional model of HVDC link in a two areas AGC studies [12]- [14].”
BackgroundAssessment of the impact of MMC‐VSC intrinsic energy on power system stability
Fradley, J., Preece, R., & Barnes, M. (2019) · The Journal of Engineering · doi:10.1049/joe.2018.8078 · Cited by 7
“A multi-terminal MMC-HVDC system is investigated in [6], and frequency response is provided using the stored electrostatic capacitive energy of the submodules (SMs) instead of the DC link capacitors.”
BackgroundMethodInfluentialBelhaouane, M. M., Almaksour, K., Papangelis, L., Gomozov, O., Colas, F., Prévost, T., Guillaud, X., & Cutsem, T. V. (2021) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2021.3107485 · Cited by 6
Bhagat, S. K., Saikia, L. C., & Babu, N. R. (2023) · IETE Journal of Research · doi:10.1080/03772063.2023.2210539 · Cited by 6
“High-voltage direct-current (HVDC) link can successfully mitigate this issue [15].”
Bhagat, S. K., Saikia, L. C., Babu, N. R., Ramoji, S. K., Raja, D., & Behera, M. K. (2022) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2022.04.078 · Cited by 4
Coordination of fast frequency support from multi-terminal HVDC grids
Jose, K., Adeuyi, O. D., Liang, J., & Ugalde‐Loo, C. E. (2018) · IEEE International Energy Conference (ENERGYCON) · doi:10.1109/energycon.2018.8398852 · Cited by 4
Self-citationBabu, N. R., Saikia, L. C., Raju, D. K., & Chiranjeevi, T. (2020) · Algorithms for intelligent systems · doi:10.1007/978-981-15-2369-4_28 · Cited by 4
On implementation of primary frequency control in MMC-HVDC transmission systems
Rink, Y., Held, L., Wenig, S., Suriyah, M., & Leibfried, T. (2017) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope.2017.8260239 · Cited by 3
“The potential of frequency support from the energy storage of MMC-HVDC and rotating mass of wind turbines is outlined in [6] and aspects of active frequency support by embedded multiterminal VSC systems (VSC-MTDC) in interconnected ac systems are addressed in [7].”
BackgroundMelendez, C., Díaz, M., Cerda, S., Rojas, F., & Chávez, H. (2018) · IEEE International Conference on Automatica · doi:10.1109/ica-acca.2018.8609738 · Cited by 3
“Therefore, there is ongoing research work to provide inertia response of wind turbines using flywheels, battery energy storage systems [8]–[10].”
BackgroundMeseret, G. M., Saikia, L. C., Behera, M. K., Ramoji, S. K., Dekaraja, B., & Bhagat, S. K. (2022) · IEEE Silchar Subsection Conference (SILCON) · doi:10.1109/silcon55242.2022.10028924 · Cited by 2
“[3] and [4] have investigated the load frequency control analysis employing HVDC tie-lines.”
MethodA review on HVDC protection system
Poongothai, C., & Gayathri, K. (2017) · doi:10.1109/iccs1.2017.8325978 · Cited by 2
Bhagat, S. K., Saikia, L. C., & Babu, N. R. (2021) · International Conference on Computational Performance Evaluation (ComPE) · doi:10.1109/compe53109.2021.9751988 · Cited by 2
Bhagat, S. K., Saikia, L. C., Babu, N. R., Dekaraja, B., Ramoji, S. K., Behera, M. K., & Das, S. (2022) · International Conference on Energy, Power and Environment (ICEPE) · doi:10.1109/icepe55035.2022.9798097 · Cited by 2
Modular Multilevel Converter With Asymmetric Capacitor Voltage for Enhanced Virtual Inertia
Chang, P., Yin, T., Shi, X., & Lin, L. (2026) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2026.3658669 · Cited by 1
“Adeuyi et al. [33] investigated the inertia support capability of MMCs in multiterminal HVDC systems, where SM capacitor energy plays a dominant role only in the initial phase of a frequency drop.”
Effect of DSTS and HVDC on Multi-Area AGC System Considering BSA Optimized 2DOF-TID Controller
Bhagat, S. K., Saikia, L. C., Babu, N. R., Dekaraja, B., Behera, M. K., & Ramoji, S. K. (2021) · IEEE India Conference · doi:10.1109/indicon52576.2021.9691729 · Cited by 1
Saha, A., Saikia, L. C., Babu, N. R., Bhagat, S. K., Behera, M. K., Ramoji, S. K., & Dekaraja, B. (2022) · Smart innovation, systems and technologies · doi:10.1007/978-981-19-2412-5_13 · Cited by 1
Lee, C., Kim, H., Shim, J. W., & Hur, K. (2019) · International Conference on Power and Energy Systems (ICPES) · doi:10.1109/icpes47639.2019.9105659 · Cited by 1
Errigo, F. (2020) · theses.fr (ABES) · doi:10.70675/805dd06cz008cz4671zb58dz73be8c5438a5 · Cited by 5
Optimal Location of IPFC on LFC Studies Considering PI-TIDN Controller and RT-Lab
Babu, N. R., Saikia, L. C., Bhagat, S. K., & Dekaraja, B. (2022) · Algorithms for intelligent systems · doi:10.1007/978-981-16-6893-7_9
Babu, N. R., Chiranjeevi, T., Devarapalli, R., & Márquez, F. P. G. (2024) · Archives of Control Sciences · doi:10.24425/acs.2024.153101
Zhang, H., Xiang, W., & Wen, J. (2024) · International Conference on Power Engineering (ICPE) · doi:10.1109/icpe64565.2024.10929418
“Proposed energy coordination control.”
Zeng, G., Liu, M., Tu, L., He, X. S., Zhu, Y., & He, P. (2025) · IEEE International Conference on Power and Integrated Energy Systems (ICPIES) · doi:10.1109/icpies65420.2025.11069979
“Several research review the methods for the wind farm-MMC-HVDC system to participate in grid frequency support, pointing out that inertia mainly comes from the DC capacitor, MMC sub-module capacitor, and the kinetic energy of the wind turbine rotor and blades [9-10].”
Metadata
- Authors
- Adeuyi, O. D., Cheah-Mane, M., Liang, J., Jenkins, N., Wu, Y., Li, C., & Wu, X.
- Affiliations
- Cardiff University (GB)
- State Grid Corporation of China (China) (CN)
- Venue
- 2015 IEEE Power & Energy Society General Meeting
- Publisher
- IEEE
- Published
- 2015-07
- Pages
- 1-5
- ISSN
- 1932-5517 (ISSN-L)
- OpenAlex
- W1812899177
- Cited by
- 56
- References
- 12
- Citations by year
- 2026: 1 · 2025: 2 · 2024: 3 · 2023: 8 · 2022: 7 · 2021: 6 · 2020: 8 · 2019: 8 · 2018: 6 · 2017: 6 · 2016: 1
- FWCI
- 5.37
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- IEEE Power Engineering Society General Meeting (publishedVersion)
- Funders
- Engineering and Physical Sciences Research Council (EP/K006312/1, EP/I013636/1, EP/E036503/1)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- multi-terminal HVDC, modular multilevel converter, frequency support, virtual inertia, voltage source converter, offshore wind farms, grid frequency stability
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.