The DOI matches its Crossref record; 128 of the 133 references it cites were found in a registry or an index.
Wearable Medical Systems for p-Health
Abstract
Driven by the growing aging population, prevalence of chronic diseases, and continuously rising healthcare costs, the healthcare system is undergoing a fundamental transformation, from the conventional hospital-centered system to an individual-centered system. Current and emerging developments in wearable medical systems will have a radical impact on this paradigm shift. Advances in wearable medical systems will enable the accessibility and affordability of healthcare, so that physiological conditions can be monitored not only at sporadic snapshots but also continuously for extended periods of time, making early disease detection and timely response to health threats possible. This paper reviews recent developments in the area of wearable medical systems for p-Health. Enabling technologies for continuous and noninvasive measurements of vital signs and biochemical variables, advances in intelligent biomedical clothing and body area networks, approaches for motion artifact reduction, strategies for wearable energy harvesting, and the establishment of standard protocols for the evaluation of wearable medical devices are presented in this paper with examples of clinical applications of these technologies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Their current capabilities include physiological and biochemical sensing, as well as motion sensing [6,7].”
From A review of wearable sensors and systems with application in rehabilitation (2012) · cites this paper as [6]
Citations
Cites
Projections of Global Mortality and Burden of Disease from 2002 to 2030
Mathers, C. D., & Loncar, D. (2006) · PLoS Medicine · doi:10.1371/journal.pmed.0030442 · Cited by 11,386
Energy Scavenging for Mobile and Wireless Electronics
Paradiso, J. A., & Starner, T. E. (2005) · IEEE Pervasive Computing · doi:10.1109/mprv.2005.9 · Cited by 2,644
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Microfibre–nanowire hybrid structure for energy scavenging
Qin, Y., Wang, X., & Wang, Z. L. (2008) · Nature · doi:10.1038/nature06601 · Cited by 1,605
Ultra-wideband radio technology: Potential and challenges ahead
Porcino, D., & Hirt, W. (2003) · IEEE Communications Magazine · doi:10.1109/mcom.2003.1215641 · Cited by 980
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876
Biomechanical Energy Harvesting: Generating Electricity During Walking with Minimal User Effort
Donelan, J. M., Li, Q., Naing, V., Hoffer, J. A., Weber, D. J., & Kuo, A. D. (2008) · Science · doi:10.1126/science.1149860 · Cited by 777
AMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707
Droitcour, A. D., Borić-Lubecke, O., Lubecke, V. M., Lin, J., & Kovacs, G. T. A. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.823552 · Cited by 662
Enhancing the quality of life through wearable technology
Park, S., & Jayaraman, S. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213625 · Cited by 615
Flagged first, then by citations
5 of the 133 references couldn’t be matched to a known paper.
Research works printed but not linked: 13
- zheng, 2003, Optimal design of finger-ring sensors for the detection of dynamic photoplethysmographic signals, Proc World Congress on Medical Physics and Biomedical Engineering
- 1992, User-wearable Hemoglobinometer for measuring the metabolic condition of a subject
- mccombie, 2008, Motion based adaptive calibration of pulse transit time measuremtns to arterial blood pressure for an autonomous, wearable blood pressure monitor, Proc 30th Ann Int Conf IEEE EMBS, 989
- 2005, Preventing chronic diseases
- scholtz, 1999, Addressing the global demands for improved healthcare, Proc Telemedicine 21st Century Opportunities Citizens Society Industry, 11
- tr�ster, 2004, MIA Yearbook of Medical Informatics 2005 Ubiquitous Health Care Systems, 125
- brodie, 2001, Epilepsy
- 2007, Why population aging matters
- 2001, Signal processing apparatus
- 2000, Method and apparatus for determining the concentration of a component
- jovanov, 2005, Wireless technology and system integration in body area networksform-Healthapplication, Proc Int Conf IEEE EMBS, 7158
- rusch, 1994, Alternate pulse oximetry algorithms for SpO2 computation, Proc 16th Ann Int Conf IEEE EMBS
- lauter, 2004, MyHeart: Fighting cardiovascular disease by preventive and early diagnosis, Stud Health Technol Inform, 108, 34
Cited by
Sorted by citations
Items 101–200 of 307
Hung, K., Lee, C. C., & Choy, S. (2015) · Springer series in bio-/neuroinformatics · doi:10.1007/978-3-319-12817-7_15 · Cited by 24
Epidermal electronics – flexible electronics for biomedical applications
Dahiya, R. (2015) · Cambridge University Press eBooks · doi:10.1017/cbo9781139629539.023 · Cited by 24
Distributed media-aware flow scheduling in cloud computing environment
Rodrigues, J. J. P. C., Zhou, L., Mendes, L. D. P., Lin, K., & Lloret, J. (2012) · Computer Communications · doi:10.1016/j.comcom.2012.03.004 · Cited by 24
A home-based smart health model
Bedón-Molina, J., López, M., & Dérpich, I. (2014) · Advances in Mechanical Engineering · doi:10.1177/1687814020935282 · Cited by 24
Energy harvesting from human motion with piezo fibers for the body monitoring by MEMS sensors
Pasquale, G. D., & Somà, A. (2013) · PORTO@Iris · Cited by 22
Marcelli, E., Capucci, A., Minardi, G., & Cercenelli, L. (2016) · ASAIO Journal · doi:10.1097/mat.0000000000000446 · Cited by 22
Ganesh, G. R. D., Jaidurgamohan, K., Srinu, V., Kancharla, C. R., & Suresh, S. V. S. (2016) · IEEE International Conference on Industrial and Information Systems (ICIIS) · doi:10.1109/iciinfs.2016.8262913 · Cited by 23
Turchioe, M. R., Burgermaster, M., Mitchell, E. G., Desai, P. M., & Mamykina, L. (2020) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2020.103572 · Cited by 23
Cannarella, J., Selvaggi, J. P., Salon, S. J., Tichy, J. A., & Borca‐Tasciuc, D. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2122265 · Cited by 22
Ergonomic Assessment of Physical Load in Slovak Industry Using Wearable Technologies
Onofrejová, D., Balažiková, M., Glatz, J., Kotianová, Z., & Vaskovicova, K. (2022) · Applied Sciences · doi:10.3390/app12073607 · Cited by 21
Wibowo, R., Do, V., Quartucci, C., Koller, D., Daanen, H. A. M., Nowak, D., Böse‐O’Reilly, S., & Rakete, S. (2023) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-023-02022-2 · Cited by 21
Kwon, J., Park, H. W., Park, Y.-B., & Kim, N. (2017) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-017-0039-5 · Cited by 21
Presti, D. L., Massaroni, C., Saccomandi, P., Caponero, M., Formica, D., & Schena, E. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037837 · Cited by 23
Kim, J., Ouh, H., & Johnston, M. L. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3131642 · Cited by 20
Tully, J. L., Dameff, C. J., & Longhurst, C. (2020) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2019.11.004 · Cited by 20
Stretchable Ag/AgCl Nanowire Dry Electrodes for High-Quality Multimodal Bioelectronic Sensing
Wang, T., Yao, S., Shao, L., & Zhu, Y. (2024) · Sensors · doi:10.3390/s24206670 · Cited by 19
Quantum-Cascade Lasers in Atmospheric Optical Communication Lines: Challenges and Prospects (Review)
Abramov, P. I., Budarin, A. S., Kuznetsov, E. V., & Skvortsov, L. A. (2020) · Journal of Applied Spectroscopy · doi:10.1007/s10812-020-01041-y · Cited by 20
Reali, P., Lolatto, R., Coelli, S., Tartaglia, G., & Bianchi, A. M. (2022) · Sensors · doi:10.3390/s22041428 · Cited by 21
Highly sensitive pressure sensor based on graphene hybrids
Vaka, M., Bian, M. Z., & Nam, N. Đ. (2018) · Arabian Journal of Chemistry · doi:10.1016/j.arabjc.2018.02.009 · Cited by 18
External Cardiac Loop Recorders: Functionalities, Diagnostic Efficacy, Challenges and Opportunities
Rajanna, R. R., Sriraam, N., Prakash, V. S. R., Vittal, P. R., Arun, U., & Sahoo, S. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2021.3055219 · Cited by 17
Application of a Textile-based Inductive Sensor for the Vital Sign Monitoring
Gi, S. O., Lee, Y. J., Koo, H. R., Khang, S., Kim, K.-N., Kang, S.-J., Lee, J. H., & Lee, J. (2015) · Journal of Electrical Engineering and Technology · doi:10.5370/jeet.2015.10.1.364 · Cited by 17
Recognition of different daily living activities using hidden Markov model regression
Safi, K., Mohammed, S., Attal, F., Khalil, M. A., & Amirat, Y. (2016) · Middle East Conference on Biomedical Engineering · doi:10.1109/mecbme.2016.7745398 · Cited by 17
UWB Indoor Location for Monitoring Dementia Patients
Grünerbl, A., Bahle, G., Hanser, F., & Lukowicz, P. (2013) · International Journal of Ambient Computing and Intelligence · doi:10.4018/ijaci.2013100104 · Cited by 16
Vibration Energy Harvester Driven Wearable Biomedical Diagnostic System
Balpande, S. S., Kalambe, J. P., & Pande, R. S. (2018) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2018.8556864 · Cited by 16
Balpande, S. S., Kalambe, J. P., & Pande, R. S. (2019) · Micro & Nano Letters · doi:10.1049/mnl.2018.5250 · Cited by 16
Handwritten character recognition via direction string and nearest neighbor matching
Li, L., Li-liang, Z., & Jing-fei, S. U. (2012) · 中国邮电高校学报:英文版 · doi:10.1016/s1005-8885(11)60427-5 · Cited by 16
Martínez-Méndez, R., Toshiyo, T., & Sekine, M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626162 · Cited by 15
Tang, W.-H., Ho, W., & Chen, Y. J. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0574-5 · Cited by 15
A novel approach to sensor implementation for healthcare systems using internet of things
Mitra, R., & Ganiga, R. (2019) · International Journal of Electrical and Computer Engineering (IJECE) · doi:10.11591/ijece.v9i6.pp5031-5045 · Cited by 15
Ferguson, C., Inglis, S. C., Breen, P. P., Gargiulo, G. D., Byiers, V., Macdonald, P. S., & Hickman, L. (2020) · JMIR Aging · doi:10.2196/17299 · Cited by 15
Intelligent health monitoring system modeling based on machine learning and agent technology
Elouni, J., Ellouzi, H., Ltifi, H., & Ayed, M. B. (2020) · Multiagent and Grid Systems · doi:10.3233/mgs-200329 · Cited by 15
Lin, W., Chen, C., & Lee, M. (2021) · Biosensors · doi:10.3390/bios11110428 · Cited by 15
An empirical study of Android Wear user complaints
Mujahid, S., Sierra, G., Abdalkareem, R., Shihab, E., & Shang, W. (2018) · Empirical Software Engineering · doi:10.1007/s10664-018-9615-8 · Cited by 15
Sub-6G Metamaterial-Based Flexible Wearable UWB Antenna for IoT and WBAN
Saeidi, T., Mahmood, S. N., Alani, S., Ali, S. M., Ismail, I. B., & Alhawari, A. R. H. (2020) · IEEE Intl Conf on Dependable, Autonomic and Secure Computing, Intl Conf on Pervasive Intelligence and Computing, Intl Conf on Cloud and Big Data Computing, Intl Conf on Cyber Science and Technology Congress (DASC/PiCom/CBDCom/CyberSciTech) · doi:10.1109/dasc-picom-cbdcom-cyberscitech49142.2020.00018 · Cited by 15
Preclinical Evaluation of a Wearable Wristband With Compressed-Sensing Based Photoplethysmography
Ahmmed, P., Garceau, E. L., Latif, T., Brewer, A., Dieffenderfer, J. P., Valero-Sarmiento, J. M., Pamula, V. R., Helleputte, N. V., Hoof, C. A. V., Verhelst, M., et al. (2024) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2024.3513462 · Cited by 15
Wearable Sensors for Pervasive and Personalized Health Care
Vijayalakshmi, A., Jose, D. V., & Unnisa, S. (2021) · Studies in computational intelligence · doi:10.1007/978-981-15-9897-5_7 · Cited by 14
Grzelczyk, D., Wojna, M., Ogińska, E., Wasilewski, G., & Awrejcewicz, J. (2024) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2024.118427 · Cited by 14
Towards Privacy by Design in Personal e-Health Systems
Drosatos, G., Efraimidis, P. S., Williams, G. A., & Kaldoudi, E. (2016) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0005821404720477 · Cited by 14
Data-Driven Healthcare: The Role of Computational Methods in Medical Innovation
Hariharasakthisudhan, P., Rajendran, S., Khalkar, V., Devarajan, G., & Kamaraj, L. (2024) · Computer Modeling in Engineering & Sciences · doi:10.32604/cmes.2024.056605 · Cited by 14
Analytic Hierarchy Process for assessing e-health technologies for elderly indoor mobility analysis
Lohan, E. S., Cramariuc, O. T., Malicki, Ł., Brenčič, N. S., & Cramariuc, B. (2015) · Wireless Mobile Communication and Healthcare · doi:10.4108/eai.14-10-2015.2261667 · Cited by 13
Alsalamah, H. A., Nasser, S., Alsalamah, S., Almohana, A. I., Alanazi, A., & Alrrshaid, F. (2021) · Frontiers in Blockchain · doi:10.3389/fbloc.2021.654539 · Cited by 13
Goy, C. B., Dominguez, J. M., López, M. A. G., Madrid, R. E., & Herrera, M. C. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.812689 · Cited by 13
Pulse wave detection method based on the bio-impedance of the wrist
He, J., Wang, M., Li, X., Li, G., & Lin, L. (2016) · Review of Scientific Instruments · doi:10.1063/1.4947514 · Cited by 13
Chen, Z., Ren, W., Ren, Y. C., & Choo, K. R. (2017) · Future Generation Computer Systems · doi:10.1016/j.future.2017.10.008 · Cited by 13
Grant, S., Blom, A. W., Craddock, I. J., Whitehouse, M. R., & Gooberman‐Hill, R. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-032205 · Cited by 13
Medical and Healthcare Textiles
Belino, N., Fangueiro, R. M. E. S., Rana, S., Glampedaki, P., & Priniotakis, G. (2019) · Wiley eBooks · doi:10.1002/9781119325062.ch4 · Cited by 13
From Enabling Technology to Clinical Applications
Bonato, P. (2010) · Cited by 12
Self-citationPasquale, G. D. (2016) · Meccanica · doi:10.1007/s11012-016-0359-5 · Cited by 12
Consumer perceptions on smart wearable devices for medical and wellness purposes
Capalbo, I., Penhaker, M., Peter, L., & Proto, A. (2019) · IEEE Technology & Engineering Management Conference (TEMSCON) · doi:10.1109/temscon.2019.8813685 · Cited by 13
Li, J., Wang, Y., Li, C., Xu, Z., Zhao, Z., Raza, S. A., & Wang, Y. (2022) · Review of Scientific Instruments · doi:10.1063/5.0073892 · Cited by 12
IoTAuth: IoT Sensor Data Analytics for User Authentication Using Discriminative Feature Analysis
Batool, S., Hassan, A., Khan, M. A., Shahzad, A., & Farooq, M. U. (2022) · IEEE Access · doi:10.1109/access.2022.3178635 · Cited by 12
Wireless Communication Technologies for Wearable Systems
Warren, S., & Natarajan, B. (2010) · Springer eBooks · doi:10.1007/978-1-4419-7384-9_3 · Cited by 12
Różanowski, K., Sondej, T., & Lewandowski, J. (2015) · International Conference Mixed Design of Integrated Circuits and Systems · doi:10.1109/mixdes.2015.7208480 · Cited by 12
Accurate cirrhosis identification with wrist-pulse data for mobile healthcare
Gong, S., Xu, B., Sun, G., Chen, M., Wang, N., Dong, C., Wang, P., & Cui, J. (2012) · ACM Workshop on Mobile Systems, Applications, and Services for Healthcare (mHealthSys) · doi:10.1145/2396276.2396283 · Cited by 12
A heart rate detection method for low power exercise intensity monitoring device
Prawiro, E. A. P. J., Hu, C.-C., Chan, Y.-S., Chang, C., & Lin, Y. (2014) · International Symposium on Bioelectronics and Bioinformatics (ISBB) · doi:10.1109/isbb.2014.6820931 · Cited by 11
Mendes, L. D. P., Rodrigues, J. J. P. C., Vasilakos, A. V., & Zhou, L. (2011) · International Conference on Communications · doi:10.1109/icc.2011.5962636 · Cited by 11
A new electro‐static micro‐generator for energy harvesting from diaphragm muscle
Daneshvar, S. H., & Maymandi‐Nejad, M. (2017) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2365 · Cited by 11
Application of wearable devices in sports: behavior change and result effect
Yang, Q., Jian, S., Zhang, Z., Ding, S. C., Zai, C., Cui, X. Y., & Li, D. Y. (2021) · International Conference on Health Big Data and Smart Sports (HBDSS) · doi:10.1109/hbdss54392.2021.00035 · Cited by 10
Bioimpedance sensing in wearable systems: From hardware integration to model development
Rossi, S., Mancarella, C., Mocenni, C., & Torre, L. D. (2017) · IEEE International Forum on Research and Technology for Society and Industry (RTSI) · doi:10.1109/rtsi.2017.8065956 · Cited by 10
Towards Self-Adaptability of Instrumented Electromagnetic Energy Harvesters
Carneiro, P. M. R., Ferreira, J., Kholkin, A. L., & dos Santos, M. P. S. (2022) · Machines · doi:10.3390/machines10060414 · Cited by 10
Pasluosta, C. F., Gaßner, H., Winkler, J., Klucken, J., & Eskofier, B. M. (2015) · EAI Endorsed Transactions on Internet of Things · doi:10.4108/eai.14-10-2015.2261705 · Cited by 10
Sung, G.-F., Chiu, S.-Y., Chang, Y.-C., Liou, Y.-C., Yeh, C.-P., & Lee, W. (2023) · Materials · doi:10.3390/ma16083229 · Cited by 9
Interconnects on elastomers: optimizing for stretchability, speed and layout area
Prasad, O., Jha, P., Sreelal, S., Prasad, M. V. N., Amrutur, B. S., & Sambandan, S. (2017) · Flexible and Printed Electronics · doi:10.1088/2058-8585/aa91ba · Cited by 9
Led, S., Azpilicueta, L., Martinez-Espronceda, M., Serrano, L., & Falcone, F. (2015) · Springer series in bio-/neuroinformatics · doi:10.1007/978-3-319-12817-7_11 · Cited by 9
Wibowo, R., Satow, M., Quartucci, C., Weinmann, T., Koller, D., Daanen, H. A. M., Nowak, D., Böse‐O’Reilly, S., & Rakete, S. (2025) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxaf026 · Cited by 12
Neri, L., Gallelli, I., Dall’Olio, M., Lago, J., Borghi, C., Diemberger, I., & Corazza, I. (2024) · Bioengineering · doi:10.3390/bioengineering11030222 · Cited by 8
Surface modified and advanced magnetoelastic sensors for biomedical application
Ramkumar, V., Periyannan, J., Gopiraman, M., Kim, S., & Muneeswaran, M. (2024) · Surfaces and Interfaces · doi:10.1016/j.surfin.2024.104247 · Cited by 8
Yoon, U.-J., Noh, Y., & Yoon, H.-R. (2011) · Biomedical Engineering Letters · doi:10.1007/s13534-011-0023-x · Cited by 8
Dias, D., Ferreira, N., & Cunha, J. P. S. (2017) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2017.7936010 · Cited by 8
Challenges in personalized systems for Personal Health Care
Fernández-Llatas, C., Martínez-Romero, A., Bianchi, A. M., Henriques, J. M. O., Carvalho, P., & Traver, V. (2016) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2016.7455908 · Cited by 8
Detection of different types of noise in lung sounds
Leal, A., Couceiro, R., Chouvarda, I., Maglaveras, N., Henriques, J. M. O., Paiva, R. P., Carvalho, P., & Teixeira, C. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7592090 · Cited by 8
Nanjappan, V., Liang, H., Wang, W., & Man, K. L. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809393-1.00001-5 · Cited by 8
Wang, Q., Chai, X., Wang, Y., Liu, D., Chen, M., Li, Y., Liu, X., & Bai, O. (2017) · International Conference on Electronics Instrumentation & Information Systems (EIIS) · doi:10.1109/eiis.2017.8298564 · Cited by 8
Menolotto, M., Rossi, S., Dario, P., & Torre, L. D. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319056 · Cited by 8
Wearable System for Acquisition and Monitoring of Biological Signals
Piccinini, D., Andino, N., Ponce, S., Roberti, M., & Lopez, Y. (2016) · Journal of Physics Conference Series · doi:10.1088/1742-6596/705/1/012009 · Cited by 8
Palma, L. D., Andria, G., Attivissimo, F., Lanzolla, A. M. L., & Nisio, A. D. (2025) · Measurement · doi:10.1016/j.measurement.2025.118210 · Cited by 7
Location-aware system for wearable physiological monitoring within hospital facilities
López, G., Custodio, V., & Moreno, J. I. (2010) · IEEE International Symposium on Personal, Indoor and Mobile Radio Communications (PIMRC) · doi:10.1109/pimrc.2010.5671779 · Cited by 7
Biomechanical Energy Harvesting
Pasquale, G. D. (2015) · Advances in environmental engineering and green technologies book series · doi:10.4018/978-1-4666-8254-2.ch011 · Cited by 8
Disi, M. A., Djelouat, H., Amira, A., & Bensaali, F. (2018) · Euromicro Conference on Digital System Design (DSD) · doi:10.1109/dsd.2018.00082 · Cited by 7
Thanapitak, S., & Sawigun, C. (2022) · European Solid-State Circuits Conference (ESSCIRC) · doi:10.1109/esscirc55480.2022.9911439 · Cited by 7
Yang, G., Xie, L., & Zheng, L. (2013) · NORCHIP · doi:10.1109/norchip.2013.6702023 · Cited by 7
Railis, K., Tsoutsouras, V., Xydis, S., & Soudris, D. (2016) · International Workshop on Power and Timing Modeling, Optimization and Simulation (PATMOS) · doi:10.1109/patmos.2016.7833699 · Cited by 7
Baali, H., Zhai, X., Djelouat, H., Amira, A., & Bensaali, F. (2017) · IEEE Access · doi:10.1109/access.2017.2780190 · Cited by 7
Electronics and orthopaedic surgery
Aldebeyan, S. A., Aoude, A., & Harvey, E. J. (2018) · Injury · doi:10.1016/s0020-1383(18)30313-9 · Cited by 7
Internet of Things Based Remote Wearable Health Solutions: Prospects and Area of ResearchPreprint
Nanda, S., Khattar, K., & Nanda, S. (2019) · SSRN Electronic Journal · doi:10.2139/ssrn.3351034 · Cited by 7
Jeet, R., & Kang, S. S. (2020) · Materials Today Proceedings · doi:10.1016/j.matpr.2020.10.083 · Cited by 7
RetractedAn Overview of Wearable Medical Device Applications
Çelik, Y. S., İLÇE, E., Mesut, B., & Özsoy, Y. (2024) · Journal of Research in Pharmacy · doi:10.29228/jrp.734 · Cited by 6
Wireless Sensor and Communication Nodes with Energy Harvesting
Şafak, M. (2014) · Journal of CONASENSE · doi:10.13052/jconasense2246-2120.113 · Cited by 6
Recent Progress in Flexible/Wearable Electronics
Kang, S. H., & Hong, S. W. (2014) · Journal of Welding and Joining · doi:10.5781/jwj.2014.32.3.34 · Cited by 6
IoMT based Pill Dispensing system
Singh, U., Sharad, A., & Kumar, P. (2019) · International Conference on Computing, Communication and Networking Technologies (ICCCNT) · doi:10.1109/icccnt45670.2019.8944886 · Cited by 6
Sports medicine: bespoke player management
Stuart, S., Powell, D., Marshall, S. J., Clark, C. C. T., Martini, D. N., Johnston, W., & Godfrey, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-818914-6.00021-1 · Cited by 6
Implanted Antennas and Intra-Body Propagation Channel for Wireless Body Area Network
Ibraheem, A. A. Y. (2014) · VTechWorks (Virginia Tech) · Cited by 6
Sonia, S. V. E., Latha, C. B. C., Jenefa, A., & Shirley, C. P. (2024) · Interdisciplinary biotechnological advances · doi:10.1007/978-981-97-4268-4_12 · Cited by 5
Li, Y., & Li, Y. L. (2019) · Journal of Circuits Systems and Computers · doi:10.1142/s0218126620501091 · Cited by 5
Smart garments in chronic disease management: progress and challenges
Khosla, A. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.979667 · Cited by 5
A Modular System for Rapid Development of Telemedical Devices
Parák, J., Dvořák, J., Havlík, J., Lhotská, L., Pokorný, M., & Horčík, Z. (2020) · Zenodo (CERN European Organization for Nuclear Research) · doi:10.3217/jucs-019-09-1242 · Cited by 5
Wearable Technologies for Neonatal Monitoring
Liu, Q., Poon, C. C. Y., & Zhang, Y. (2012) · IGI Global eBooks · doi:10.4018/978-1-4666-0975-4.ch002 · Cited by 5
Self-citationA low cost capacitive sensing system for identifying and detecting falls of senior citizens
Arshad, A., Kadir, K., Khan, S., Alam, A. H. M. Z., & Tasnim, R. (2015) · IEEE International Conference on Smart Instrumentation, Measurement and Applications (ICSIMA) · doi:10.1109/icsima.2015.7559004 · Cited by 5
Alerting system for sport activity based on ECG signals using proportional integral derivative
Octaviani, V., Kurniawan, A. R., Suprapto, Y. K., & Zaini, A. A. (2017) · Proceeding of the Electrical Engineering Computer Science and Informatics · doi:10.1109/eecsi.2017.8239104 · Cited by 5
Metadata
- Authors
- Teng, X.-F., Zhang, Y.-T., Poon, C. C. Y., & Bonato, P.
- Affiliations
- Chinese University of Hong Kong (HK)
- Harvard University (US)
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2008
- Volume
- 1
- Pages
- 62-74
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W2156014240
- Cited by
- 310
- References
- 133
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 16 · 2023: 15 · 2022: 22 · 2021: 18 · 2020: 14 · 2019: 26 · 2018: 23 · 2017: 28 · 2016: 23 · 2015: 25 · 2014: 21 · 2013: 21 · 2012: 20
- FWCI
- 0.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Reviews in Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- continuous physiological monitoring, biochemical monitoring, body area networks, motion artifact reduction, wearable energy harvesting, early disease detection
- MeSH terms
- Animals, Biomedical Engineering, Equipment Design, Humans, Telemedicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review