The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Continuum robots - a state of the art
Abstract
Like the human limbs which inspired them most robots are discrete mechanisms with rigid links connected by single degree of freedom joints. In contrast, 'continuum' and 'serpentine' robot mechanisms move by bending through a series of continuous arcs producing motion which resembles that of biological tentacles or snakes. This paper provides a single reference to the expanding technology of continuum robot mechanisms. It defines the fundamental difference between discrete, serpentine and continuum robot devices, presents the 'state of the art' of continuum robots, outlines their areas of application, and introduces some control issues. Finally, some conclusions regarding the continued development of these devices are made.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tongues, Tentacles and Trunks: the Biomechanics of Movement in Muscular-Hydrostats
KIER, W. M., & SMITH, K. K. (1985) · Zoological Journal of the Linnean Society · doi:10.1111/j.1096-3642.1985.tb01178.x · Cited by 910
Robot Grasp Synthesis Algorithms: A Survey
Shimoga, K. B. (1996) · The International Journal of Robotics Research · doi:10.1177/027836499601500302 · Cited by 666
Development of flexible microactuator and its applications to robotic mechanisms
Suzumori, K., Iikura, S., & Tanaka, H. (2002) · Proceedings. 1991 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1991.131850 · Cited by 408
Immega, G., & Antonelli, K. (2002) · Proceedings of 1995 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.1995.525733 · Cited by 165
Electrostrictive polymer artificial muscle actuators
Kornbluh, R. D., Pelrine, R. E., Eckerle, J. S., & Joseph, J. P. (2002) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.1998.680638 · Cited by 149
Tondu, B., & Lòpez, P. (1997) · Industrial Robot the international journal of robotics research and application · doi:10.1108/01439919710192563 · Cited by 116
Integrated flexible microactuator systems
Suzumori, K., Koga, A., Kondo, F., & 羽田里代子 (1996) · Robotica · doi:10.1017/s0263574700019974 · Cited by 22
Cited by
Design and Kinematic Modeling of Constant Curvature Continuum Robots: A Review
Webster, R. J., & Jones, B. A. (2010) · The International Journal of Robotics Research · doi:10.1177/0278364910368147 · Cited by 2,297
Soft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708
Soft robotics: Technologies and systems pushing the boundaries of robot abilities
Laschi, C., Mazzolai, B., & Cianchetti, M. (2016) · Science Robotics · doi:10.1126/scirobotics.aah3690 · Cited by 1,570
Continuum Robots for Medical Applications: A Survey
Burgner-Kahrs, J., Rucker, D. C., & Choset, H. (2015) · IEEE Transactions on Robotics · doi:10.1109/tro.2015.2489500 · Cited by 1,557
Kinematics for multisection continuum robots
Jones, B. A., & Walker, I. D. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2005.861458 · Cited by 955
Metadata
- Authors
- Robinson, G., & Davies, J. B. C.
- Venue
- Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C)
- Publisher
- IEEE
- Published
- 2003-01-20
- Volume
- 4
- Pages
- 2849-2854
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W1891615552
- Cited by
- 619
- References
- 7
- FWCI
- 20.33
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.