Minimum jerk trajectory control for rehabilitation and haptic applications
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Smooth trajectories are essential for safe interaction in between human and a haptic interface. Different methods and strategies have been introduced to create such smooth trajectories. This paper studies the creation of human-like movements in haptic interfaces, based on the study of human arm motion. These motions are intended to retrain the upper limb movements of patients that lose manipulation functions following stroke. We present a model that uses higher degree polynomials to define a trajectory and control the robot arm to achieve minimum jerk movements. It also studies different methods that can be driven from polynomials to create more realistic human-like movements for therapeutic purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The coordination of arm movements: an experimentally confirmed mathematical model
Flash, T., & Hogan, N. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-07-01688.1985 · Cited by 4,395
Kinematic features of unrestrained vertical arm movements
Atkeson, C., & Hollerbach, J. (1985) · The Journal of Neuroscience · doi:10.1523/jneurosci.05-09-02318.1985 · Cited by 926
Cited by
Augmented visual, auditory, haptic, and multimodal feedback in motor learning: A review
Sigrist, R., Rauter, G., Riener, R., & Wolf, P. (2013) · Psychonomic Bulletin & Review · doi:10.3758/s13423-012-0333-8 · Cited by 1,416
Poststroke Upper Extremity Rehabilitation: A Review of Robotic Systems and Clinical Results
Brewer, B. R., McDowell, S. K., & Worthen-Chaudhari, L. C. (2007) · Topics in Stroke Rehabilitation · doi:10.1310/tsr1406-22 · Cited by 301
Advances in upper limb stroke rehabilitation: a technology push
Loureiro, R. C. V., Harwin, W. S., Nagai, K., & Johnson, M. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0797-0 · Cited by 252
Self-citationMultimodal collaborative handwriting training for visually-impaired people
Plimmer, B., Crossan, A., Brewster, S. A., & Blagojevic, R. (2008) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1357054.1357119 · Cited by 84
Hu, Z., Hao, M., Xu, S., Xiao, Q., & Lan, N. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0505-0 · Cited by 38
Metadata
- Authors
- Amirabdollahian, F., Loureiro, R., & Harwin, W.
- Venue
- Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292)
- Publisher
- IEEE
- Published
- 2003-06-25
- Volume
- 4
- Pages
- 3380-3385
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2169983797
- Cited by
- 100
- References
- 2
- FWCI
- 7.55
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Minimum jerk trajectory control for rehabilitation and haptic applications. https://app.cochat.ai/papers/10.1109/robot.2002.1014233
- The paper
- Amirabdollahian, F., Loureiro, R., & Harwin, W. (2003). Minimum jerk trajectory control for rehabilitation and haptic applications. Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292). https://doi.org/10.1109/robot.2002.1014233
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.