Fuzzy Lifetime Analysis of a Fault-Tolerant Two-Phase Interleaved Converter
Open accessAbstract
Interleaved converters are used in photovoltaic (PV) applications to handle high power conditions with high reliability. To improve the reliability of these converters, redundant switch configuration can be employed which reduce the failure rates of the power switches significantly. However, evaluation reliability of the interleaved converters equipped with redundant switch configurations may be complex. This paper aims to simplify the reliability Analysis of interleaved converters considering mission profile and redundant switch configuration. Different possible configurations of the studied converter are shown as Markov chain states in the proposed method, which simplify the reliability and failure rates Analysis. The effect of different parameters such as the converter power level, switch configuration type, and operation modes are derived and a better insight into the effectiveness of the switch configuration on improving the reliability is provided.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cites
Power electronics as efficient interface in dispersed power generation systems
Blaabjerg, F., Chen, Z., & Kjær, S. B. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833453 · Cited by 2,593 · see citing works
On the centroids of fuzzy numbers
Wang, Y., Yang, J., Xu, D., et al. (2005) · Fuzzy Sets and Systems · doi:10.1016/j.fss.2005.11.006 · Cited by 354 · see citing works
Zhou, D., Wang, H., & Blaabjerg, F. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2769161 · Cited by 200 · see citing works
A Guideline for Reliability Prediction in Power Electronic Converters
Peyghami, S., Wang, Z., & Blaabjerg, F. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.2981933 · Cited by 193 · see citing works
Jamshidpour, E., Poure, P., & Saadate, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2421880 · Cited by 187 · see citing works
An extension to Fuzzy Fault Tree Analysis (FFTA) application in petrochemical process industry
Lavasani, S. M. M., Zendegani, A., & Çelik, M. (2014) · Process Safety and Environmental Protection · doi:10.1016/j.psep.2014.05.001 · Cited by 183 · see citing works
Dhople, S. V., Davoudi, A. A., Domínguez-García, A. D., & Chapman, P. L. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2103329 · Cited by 175 · see citing works
A Modular Fuel Cell, Modular DC–DC Converter Concept for High Performance and Enhanced Reliability
Palma, L., & Enjeti, P. N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2012498 · Cited by 138 · see citing works
A survey of SiC power MOSFETs short-circuit robustness and failure mode analysis
Ceccarelli, L., Reigosa, P. D., Iannuzzo, F., & Blaabjerg, F. (2017) · Microelectronics Reliability · doi:10.1016/j.microrel.2017.06.093 · Cited by 93 · see citing works
Ahn, J., Noh, Y., Park, S. H., et al. (2017) · Journal of Power Sources · doi:10.1016/j.jpowsour.2017.08.028 · Cited by 80 · see citing works
Mohanta, D. K., Sadhu, P. K., & Chakrabarti, R. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857932 · Cited by 63 · see citing works
Fuzzy-based approaches to substation reliability evaluation
Bai, X., & Asgarpoor, S. (2003) · Electric Power Systems Research · doi:10.1016/j.epsr.2003.08.011 · Cited by 53 · see citing works
Incorporating a Combined Fuzzy and Probabilistic Load Model in Power System Reliability Assessment
Li, W., Zhou, J., Lu, J., et al. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901676 · Cited by 46 · see citing works
A new approach to real-time reliability analysis of transmission system using fuzzy Markov model
TANRIOVEN, M., Wu, Q., Turner, D. R., et al. (2004) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2004.07.004 · Cited by 40 · see citing works
Farhadi, M., Abapour, M., & Sabahi, M. (2016) · Engineering Failure Analysis · doi:10.1016/j.engfailanal.2016.06.010 · Cited by 37 · see citing works
Self-citationDesign and analysis of a switched‐capacitor DC‐DC converter with variable conversion ratio
Kurdkandi, N. V., Farhadi, M., Babaei, E., et al. (2020) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.2849 · Cited by 36 · see citing works
Self-citationRahimi, T., Ding, L., Faraji, R., et al. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3044706 · Cited by 24 · see citing works
Self-citationFault Current Limiter Dynamic Voltage Restorer (FCL-DVR) With Reduced Number of Components
Ghavidel, P., Farhadi, M., Dabbaghjamanesh, M., et al. (2021) · IEEE Journal of Emerging and Selected Topics in Industrial Electronics · doi:10.1109/jestie.2021.3051586 · Cited by 24 · see citing works
Self-citationReliability evaluation of a fault-tolerant three-phase interleaved DC-DC boost converter
Rahimi, T., Hosseini, S. H., Sabahi, M., et al. (2018) · Transactions of the Institute of Measurement and Control · doi:10.1177/0142331218776722 · Cited by 22 · see citing works
Self-citationRahimi, R., Farhadi, M., Moradi, G. R., et al. (2020) · IEEE Kansas Power and Energy Conference (KPEC) · doi:10.1109/kpec47870.2020.9167569 · Cited by 22 · see citing works
Self-citationReliability analysis of component-level redundant topologies for solid-state fault current limiter
Farhadi, M., Abapour, M., & Mohammadi‐Ivatloo, B. (2017) · International Journal of Electronics · doi:10.1080/00207217.2017.1378380 · Cited by 20 · see citing works
Self-citationRahimi, T., Jahan, H. K., Blaabjerg, F., et al. (2018) · Applied Sciences · doi:10.3390/app9010088 · Cited by 20 · see citing works
Self-citationAghili, S. J., & Hajian-Hoseinabadi, H. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2016.08.010 · Cited by 17 · see citing works
Rahimi, T., Hosseini, S. H., Sabahi, M., & Alishah, R. S. (2016) · Progress In Electromagnetics Research M · doi:10.2528/pierm15112504 · Cited by 16 · see citing works
Self-citationJahan, H. K., Eskandari, R., Rahimi, T., et al. (2021) · Energies · doi:10.3390/en14071915 · Cited by 15 · see citing works
Self-citationRahimi, T., Ding, L., Abadifard, A., Ghavidel, P., Farhadi, M., & Faraji, R. (2021) · Case Studies in Thermal Engineering · doi:10.1016/j.csite.2021.101134 · Cited by 13 · see citing works
Self-citationSystem Reliability Analysis Method Based on Fuzzy Probability
Li, Z., Zhou, J., & Liu, B. (2017) · International Journal of Fuzzy Systems · doi:10.1007/s40815-017-0363-5 · Cited by 12 · see citing works
Reliability analysis of a robotic system using hybridized technique
Kumar, N., Komal, & Lather, J. S. (2017) · Journal of industrial engineering international · doi:10.1007/s40092-017-0235-5 · Cited by 9 · see citing works
A Novel Modulation Method to Reduce Leakage Current in Transformerless Z-source PV Inverters
Abadifard, A., Ghavidel, P., Taherkhani, N., et al. (2020) · IEEE Dallas Circuits and Systems Conference (DCAS) · doi:10.1109/dcas51144.2020.9330676 · Cited by 6 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
AC Power Cycling Test Setup and Condition Monitoring Tools for SiC-Based Traction Inverters
Farhadi, M., Vankayalapati, B. T., Sajadi, R., & Akin, B. (2023) · IEEE Transactions on Vehicular Technology · doi:10.1109/tvt.2023.3271251 · Cited by 24 · see citing works
“These includetheuseofhardwareredundancy[17],[18],activethermal control[19],[20],anddevicestateofhealthmonitoring[21], [22],[23].”
Self-citation
- Authors
- Rahimi, T., Farhadi, M., Loo, K. H., & Pou, J.
- Affiliations
- Shandong University (CN)
- The University of Texas at Dallas (US)
- Hong Kong Polytechnic University (HK)
- Nanyang Technological University (SG)
- Venue
- 2021 IEEE 13th International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED)
- Publisher
- IEEE
- Published
- 2021-08-22
- Volume
- 76 77
- Pages
- 407-412
- OpenAlex
- W3214940122
- Cited by
- 4
- References
- 29
- Citations by year
- 2024: 1 · 2023: 2 · 2022: 1
- FWCI
- 1.57
- Type
- conference paper
- Language
- en
- Open access
- green
- arxiv.org
- Licence
- Locations
- IEEE International Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives (SDEMPED) (publishedVersion)
- arXiv (Cornell University) (submittedVersion, public-domain)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University) (public-domain)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Reliability and Maintenance Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Keywords
- interleaved converter, two-phase converter, fault tolerance, reliability analysis, Markov chain model, photovoltaic converters, mission profile
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review