CoChat

AC Power Cycling Test Setup and Condition Monitoring Tools for SiC-Based Traction Inverters

Open access
Farhadi, Masoud, Vankayalapati, Bhanu Teja, Sajadi, Rahman, Akin, Bilal · 2023 · IEEE Transactions on Vehicular Technology

The DOI matches its Crossref record; 95 of the 97 references it cites were found in a registry or an index; 7 of the 74 sources its claims cite were checked for support.

Abstract

AC power cycling tests allow the most realistic reliability assessment by applying close to real stress to the device or module under test to meet functional safety standards, which is highly critical for traction applications. This article presents a comprehensive guideline and shares critical know-how to develop a 120 KVA AC power cycling test setup for high-power Silicon Carbide (SiC) modules. As of today, traction applications can not generate an early warning signal for drivers to replace critical components on time. For this purpose, the suitable precursors for all dominant failure mechanisms are discussed, and the corresponding condition monitoring tools are proposed to monitor the device aging on power converters. These condition monitoring tools are integrated into the built-in desaturation protection circuit of the electric vehicle (EV) gate driver for low-cost, practical implementation. The on-resistance of all twelve switches is monitored online as a temperature-sensitive electrical parameter (TSEP) to measure the junction temperature of the devices. To avoid heavy processing load in the microcontroller, the out-of-order equivalent time sampling technique is developed for data sampling, which leads to a measurement error of less than 1.5%. In addition, the design considerations regarding common mode noise and aging effect on DESAT protection are investigated, and experimental findings are presented.

Overview

CoChat Summary

TL;DR

The paper presents a 120 KVA AC power cycling test setup for high-power SiC traction inverter modules and integrates condition monitoring into the DESAT gate-driver protection circuit. It selects on-resistance, body diode voltage, and threshold voltage as aging precursors, uses on-resistance as a TSEP for junction temperature, and reports less than 1.5% error for filtered online on-resistance measurement.

Key findings

  • A 120 KVA AC power cycling setup was developed using two back-to-back three-phase inverters, with SiC modules as the inverter under test and IGBT modules as the electrical load; it supports up to 400 A and programmable modulation index, switching frequency, fundamental frequency, DC-link voltage, current amplitude, and power factor.
  • On-resistance, body diode voltage, and threshold voltage were selected to monitor package, body diode, and gate-oxide degradation, with their condition monitoring circuits integrated into the DESAT protection circuit to reduce component count.
  • Online on-resistance was used as the TSEP for junction temperature; the out-of-order equivalent time sampling technique captures 300 data points around peak values, and after FIR filtering the online on-resistance measurement error is less than 1.5% compared with Keysight 1506A curve tracer results.
  • Threshold voltage measurement error was less than 0.1 V compared with the curve tracer, and oxide aging increased drain-to-source voltage from 1.58 V to 2.6 V at nominal current with Vgs = 15 V, which can cause false DESAT triggers unless threshold-voltage shift is used to adjust the DESAT threshold.

Methods

  • Design and experimental validation of a 120 KVA AC power cycling test setup with two three-phase back-to-back inverters, separate active liquid cooling, laminated busbars, three 700 µH/400 A inductors, UCC5870 gate drivers, and an F28388D C2000 MCU.
  • Condition monitoring circuits were developed for on-resistance/body-diode voltage and threshold voltage, integrated into the DESAT protection circuit; TSEPs were compared, and on-resistance was selected for online junction temperature measurement.
  • Main analysis included precursor comparison, TSEP table evaluation, experimental waveforms in motor mode (PF = 1) and generator mode (PF = -1), thermal cycling, aging experiments, and error comparison against a Keysight 1506A curve tracer.

Limitations

  • Stated in the paper: the constant case-temperature-swing technique using an NTC sensor may introduce measurement inaccuracies; DESAT is susceptible to noise in high-voltage applications; on-resistance is nonlinear with temperature and dependent on package and gate-oxide degradation, requiring periodic recalibration/compensation; body diode voltage at high currents is affected by package degradation; online threshold voltage measurement requires fast sampling.
  • Evident from the text: validation is limited to a laboratory AC power cycling setup and specific SiC modules/vendors, with no field deployment or long-term lifetime extrapolation reported.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1109/tvt.2023.3271251

Cites

95 of 95 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

6 Valid · 16 Not valid · 44 Not checked · 111 Own results and interpretations

72 more claims

Create a free account to see all 177 claims and every source verdict.

See all claims — free account
  • Probably not a substantial claim. 67
  • It may state two separate claims as one. 51
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 95 references

Research works printed but not linked: 2

  1. Suganuma, 2018, Wide Bandgap Power Semiconductor Packaging: Materials, Components, and Reliability
  2. 2010, Temperature, Bias, and Operating Life

Cited by

See all 24

Metadata

Authors
Farhadi, M., Vankayalapati, B. T., Sajadi, R., & Akin, B.
Affiliations
  • The University of Texas at Dallas (US)
  • Texas Instruments (United States) (US)
Venue
IEEE Transactions on Vehicular Technology
Published
2023-10
Volume
72
Issue
10
Pages
12728-12743
ISSN
  • 0018-9545 (ISSN-L)
  • 1939-9359
OpenAlex
W4367663380
Cited by
24
References
97
Citations by year
2026: 6 · 2025: 4 · 2024: 13 · 2023: 1
FWCI
1.79
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Vehicular Technology (publishedVersion)
  • arXiv (Cornell University) (submittedVersion, public-domain)
  • arXiv (Cornell University) (public-domain)
Funders
Texas Instrument Automotive Group and Semiconductor Research Corporation/Texas Analog Center of Excellence (2810.054)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Silicon Carbide Semiconductor Technologies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power Systems and Control
Keywords
traction inverter, condition monitoring, device aging, failure mechanisms, temperature-sensitive electrical parameters, junction temperature, equivalent time sampling, common-mode noise, reliability analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Cited sources are checked with a language model’s help (gpt-6-sol).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: AC Power Cycling Test Setup and Condition Monitoring Tools for SiC-Based Traction Inverters. https://app.cochat.ai/papers/10.1109/tvt.2023.3271251
The paper
Farhadi, M., Vankayalapati, B. T., Sajadi, R., & Akin, B. (2023). AC Power Cycling Test Setup and Condition Monitoring Tools for SiC-Based Traction Inverters. IEEE Transactions on Vehicular Technology. https://doi.org/10.1109/tvt.2023.3271251

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.