CoChat

A novel 7 degrees of freedom model for upper limb kinematic reconstruction based on wearable sensors

Peppoloni, Lorenzo, Filippeschi, Alessandro, Ruffaldi, Emanuele, Avizzano, Carlo Alberto · 2013 · 2013 IEEE 11th International Symposium on Intelligent Systems and Informatics (SISY)
Cited by 51

The DOI matches its Crossref record.

Abstract

Wearable motion tracking systems have gained large popularity in the last decades because of their effectiveness in many fields, from performance assessment to human-robot interaction. Among all the approaches, those based on inertial sensors have been widely explored. Since inertial sensors are affected by measurements drift, they need to be aided by other sensors, thus requiring sensor measurements to be fused. The most used sensor fusion techniques are based on Kalman filter. In particular, the Extended Kalman Filter (EKF) and the Unscented Kalman Filter (UKF) are used because of the non linearity characterizing most of the models. They often aim at reconstructing human motion by estimating limbs orientation, involving human's kinematics to constrain relative motion of the limbs. These models often neglect part of the degrees of freedom (DoFs) that characterize human upper limbs, especially when modeling humerus motion with respect to the chest. In this paper we present a novel 7 DoFs model which represents a trade-off between modeling accuracy and complexity for the human upper limb. In particular, we model the human shoulder girdle taking into account also the humerus head's elevation and the retraction due to the scapula's and the clavicle's motions. The model exploits inertial sensors measurements by means of an Unscented Kalman filter to reconstruct human movements. The system performance is validated firstly against a reconstruction based on an optical tracking system. Secondly, the 5 DoFs model extracted form the 7 DoFs one was checked to have state of the art performance and used to estimate the improvement of position estimation that are obtained by extending the model to 7 DoFs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/sisy.2013.6662551

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 51

Metadata

Authors
Peppoloni, L., Filippeschi, A., Ruffaldi, E., & Avizzano, C. A.
Venue
2013 IEEE 11th International Symposium on Intelligent Systems and Informatics (SISY)
Publisher
IEEE
Published
2013-09
Pages
105-110
OpenAlex
W2033484375
Cited by
51
References
0
FWCI
6.49
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel 7 degrees of freedom model for upper limb kinematic reconstruction based on wearable sensors. https://app.cochat.ai/papers/10.1109/sisy.2013.6662551
The paper
Peppoloni, L., Filippeschi, A., Ruffaldi, E., & Avizzano, C. A. (2013). A novel 7 degrees of freedom model for upper limb kinematic reconstruction based on wearable sensors. 2013 IEEE 11th International Symposium on Intelligent Systems and Informatics (SISY). https://doi.org/10.1109/sisy.2013.6662551

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.