The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Operation of chemically sensitive field-effect sensors as a function of the insulator-electrolyte interface
Abstract
All chemical sensors based upon the field-effect principle share a common quality. Their measurable properties can be described in terms of a flat-band voltage. The various terms in the expression of the flat-band voltage are described and discussed, and in particular the voltage drop at the insulator-electrolyte interface. It is shown that this voltage drop depends on thepHof the electrolyte and is determined by two parameters, thepHat the point of zero charge, and a sensitivity parameter which is introduced in this paper. These parameters are obtained from the site-dissociation model of the insulator-electrolyte interface, combined with the Gouy-Chapmann-Stern theory of the electrical double layer at this interface. The theoretical description is used to interpret experimental results obtained from insulators with widely different properties, namely SiO2and Al2O3.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of an Ion-Sensitive Solid-State Device for Neurophysiological Measurements
Bergveld, P. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502688 · Cited by 2,134
Self-citation
Cited by
Bergveld, P. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00301-5 · Cited by 1,582
Self-citationLight-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Lin, S., Xu, L., Chi Wang, A., & Wang, Z. L. (2020) · Nature Communications · doi:10.1038/s41467-019-14278-9 · Cited by 678
Simultaneous DNA amplification and detection using a pH-sensing semiconductor system
Toumazou, C., Shepherd, L. M., Reed, S. C., Chen, G. I., Patel, A., Garner, D. M., Wang, C.-J. A., Ou, C.-P., Amin-Desai, K., Athanasiou, P., et al. (2013) · Nature Methods · doi:10.1038/nmeth.2520 · Cited by 356
Waleed Shinwari, M., Jamal Deen, M., & Landheer, D. (2007) · Microelectronics Reliability · doi:10.1016/j.microrel.2006.10.003 · Cited by 268
Metadata
- Authors
- Bousse, L., De Rooij, N. F., & Bergveld, P.
- Venue
- IEEE Transactions on Electron Devices
- Published
- 1983-10
- Volume
- 30
- Issue
- 10
- Pages
- 1263-1270
- ISSN
- 0018-9383 (ISSN-L)
- 1557-9646
- OpenAlex
- W2058763428
- Cited by
- 574
- References
- 1
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Operation of chemically sensitive field-effect sensors as a function of the insulator-electrolyte interface. https://app.cochat.ai/papers/10.1109/t-ed.1983.21284
- The paper
- Bousse, L., De Rooij, N. F., & Bergveld, P. (1983). Operation of chemically sensitive field-effect sensors as a function of the insulator-electrolyte interface. IEEE Transactions on Electron Devices. https://doi.org/10.1109/t-ed.1983.21284
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.