Relationship of Ultrasonic Spectral Parameters to Features of Tissue Microstructure
The DOI matches its Crossref record.
Abstract
Absfract-&mlytical studies have been conducted to investigate the importance of specific tissue features in determining ultrasonic spectral “signatures” that have proven to be diagnostically useful. Three models of tissue microstructure were considered, and calibrated power spectra were computed for a series of scatterer sizes, concentrations, and acoustic impedances. General results were obtained, then specific parameters were employed to simulate studies of the eye and liver. These results were compared to clinical data-base information, and excellent correspondence was found. Studies using acoustic microscopy, test objects, and clinical data are continuing to refine the analytical model. I. INTRODUCTION U
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in ultrasound biomicroscopy
Foster, F. S., Pavlin, C. J., Harasiewicz, K. A., Christopher, D. A., & Turnbull, D. H. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00096-4 · Cited by 719
Texture features for classification of ultrasonic liver images
Wu, C.-M., Chen, Y.-C., & Hsieh, K.-S. (1992) · IEEE Transactions on Medical Imaging · doi:10.1109/42.141636 · Cited by 476
Oelze, M. L., & Mamou, J. (2016) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2015.2513958 · Cited by 383
Quantitative Ultrasound in Soft Tissues
(2013) · Springer eBooks · doi:10.1007/978-94-007-6952-6 · Cited by 302
Czarnota, G. J., Kolios, M. C., Abraham, J., Portnoy, M., Ottensmeyer, F. P., Hunt, J. W., & Sherar, M. D. (1999) · British Journal of Cancer · doi:10.1038/sj.bjc.6690724 · Cited by 273
Oelze, M. L., O'Brien, W. D., Blue, J. P., & Zachary, J. F. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.826953 · Cited by 257
Pirmoazen, A. M., Khurana, A., El Kaffas, A., & Kamaya, A. (2020) · Theranostics · doi:10.7150/thno.40249 · Cited by 165
Skeletal Muscle Assessment Using Quantitative Ultrasound: A Narrative Review
Ashir, A., Jerban, S., Barrère, V., Wu, Y., Shah, S. B., Andre, M. P., & Chang, E. Y. (2023) · Sensors · doi:10.3390/s23104763 · Cited by 57
“Methods have been proposed to estimate microstructural parameters of tissues based on tissue models, such as effective scatter diameter (ESD) and effective acoustic concentration (EAC) [88,93,94].”
Background
Metadata
- Authors
- Lizzi, F. L., Ostromogilsky, M., Feleppa, E. J., Rorke, M. C., & Yaremko, M. M.
- Venue
- IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control
- Published
- 1987-05
- Volume
- 34
- Issue
- 3
- Pages
- 319-329
- ISSN
- 0885-3010 (ISSN-L)
- OpenAlex
- W2128824469
- Cited by
- 496
- References
- 0
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.