A Distributed Cyber-Attack Detection Scheme With Application to DC Microgrids
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
DC microgrids often present a hierarchical control architecture, requiring integration of communication layers. This leads to the possibility of malicious attackers disrupting the overall system. Motivated by this application, in this article, we present a distributed monitoring scheme to provide attack-detection capabilities for linear large-scale systems. The proposed architecture relies on a Luenberger observer together with a bank of unknown-input observers at each subsystem, providing attack detection capabilities. We describe the architecture and analyze conditions under which attacks are guaranteed to be detected, and, conversely, when they are stealthy. Our analysis shows that some classes of attacks cannot be detected using either module independently; rather, by exploiting both modules simultaneously, we are able to improve the detection properties of the diagnostic tool as a whole. Theoretical results are backed up by simulations, where our method is applied to a realistic model of a low-voltage DC microgrid under attack.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Attack Detection and Identification in Cyber-Physical Systems
Pasqualetti, F., Dorfler, F., & Bullo, F. (2013) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2013.2266831 · Cited by 2,109 · cited 1×
“Hence, the stealthiness properties differ with respect to those available in the literature [10], [24].”
BackgroundA general unified approach to modelling switching-converter power stages
Middlebrook, R. D., & Cuk, S. (1976) · 1976 IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.1976.7072895 · Cited by 1,790 · cited 1×
“Remark 3: In the literature, the design of controllers for DCmGs with DC–DC converters often relies on the so-called state-space averaging method, to disregard the switching behavior of the terminal input [37].”
BackgroundA secure control framework for resource-limited adversaries
Teixeira, A., Shames, I., Sandberg, H., & Johansson, K. H. (2015) · Automatica · doi:10.1016/j.automatica.2014.10.067 · Cited by 1,187 · cited 1×
“Many knowledge-based techniques are available, most of which have focused on centralized architectures to detect malicious intrusion and tampering of the communication between plants and controllers [23]–[26].”
BackgroundSecurity and Privacy Challenges in the Smart Grid
McDaniel, P., & McLaughlin, S. (2009) · IEEE Security & Privacy Magazine · doi:10.1109/msp.2009.76 · Cited by 1,165 · cited 1×
“An area that has received specific attention because of its criticality has been the secure control and estimation of power networks, with specific focus on smart grids [9], [15]–[17], and microgrids [18]–[21].”
BackgroundCyber–Physical Security of a Smart Grid Infrastructure
Mo, Y., Kim, T. H.-J., Brancik, K., Dickinson, D., Lee, H., Perrig, A., & Sinopoli, B. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2161428 · Cited by 1,096
Secure Control: Towards Survivable Cyber-Physical Systems
Cardenas, A. A., Amin, S., & Sastry, S. (2008) · 2008 The 28th International Conference on Distributed Computing Systems Workshops · doi:10.1109/icdcs.workshops.2008.40 · Cited by 911 · cited 1×
“This is due to the fact that modern control systems are evermore exposed to cyber-attacks, given the increasing integration of physical and cyber resources in CPS control loops [14].”
BackgroundDesign of unknown input observers and robust fault detection filters
CHEN, J., PATTON, R. J., & ZHANG, H.-Y. (1996) · International Journal of Control · doi:10.1080/00207179608921833 · Cited by 835 · cited 5×
“The following necessary and sufficient conditions are given in [43] to verify the possibility of designing the UIO (8):”
BackgroundInfluentialState and Input Estimation for a Class of Uncertain Systems
Corless, M., & Tu, J. F. (1998) · Automatica · doi:10.1016/s0005-1098(98)00013-2 · Cited by 611
Security Technology for Smart Grid Networks
Metke, A. R., & Ekl, R. L. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2046347 · Cited by 608 · cited 1×
“An area that has received specific attention because of its criticality has been the secure control and estimation of power networks, with specific focus on smart grids [9], [15]–[17], and microgrids [18]–[21].”
BackgroundKhurana, H., Hadley, M., Lu, N., & Frincke, D. A. (2010) · IEEE Security & Privacy Magazine · doi:10.1109/msp.2010.49 · Cited by 606 · cited 1×
“An area that has received specific attention because of its criticality has been the secure control and estimation of power networks, with specific focus on smart grids [9], [15], [16], [17], and microgrids [18], [19], [20], [21].”
Background
Cited by
Yuan, T., Gao, F., Bai, J., & Sun, H. (2025) · Journal of Power Sources · doi:10.1016/j.jpowsour.2025.236193 · Cited by 14
Metadata
- Authors
- Gallo, A. J., Turan, M. S., Boem, F., Parisini, T., & Ferrari-Trecate, G.
- Venue
- IEEE Transactions on Automatic Control
- Published
- 2020-09
- Volume
- 65
- Issue
- 9
- Pages
- 3800-3815
- ISSN
- 0018-9286 (ISSN-L)
- 1558-2523
- 2334-3303
- OpenAlex
- W3014429688
- Cited by
- 187
- References
- 32
- FWCI
- 12.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.