The DOI matches its Crossref record.
Performances of an Implanted Cavity Slot Antenna Embedded in the Human Arm
Abstract
Implantable devices have been investigated with great interest as communication tools. These implantable devices are embedded into the human or pet body. The vital information (such as temperature, blood pressure, cardiac beat, etc.) can be transmitted from implantable devices to the external equipment by use of a wireless communication link. Therefore, the research on the antenna for implantable devices (implanted antennas) is very important. This paper proposes an implanted H-shaped cavity slot antenna for short-range wireless communications. This type of antenna, which is designed to operate at the industrial-scientific-medical band (2.45 GHz), is investigated by using finite-difference time-domain calculation. We analyzed the performances of the proposed antenna which is embedded into the human body between the shoulder and the elbow. However, since the proposed antenna is too small to fabricate, a scale model is adopted for antenna measurements. Some characteristics of the scale model of the antenna are also calculated and measured by using the 2/3 muscle-equivalent phantom. The results show that the proposed antenna has promise for use in an implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Liu, C., Guo, Y.-X., & Xiao, S. (2014) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2014.2307341 · Cited by 316
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Wireless power transfer approaches for medical implants: a review
Haerinia, M., & Shadid, R. (2020) · Signals · doi:10.3390/signals1020012 · Cited by 174
“Assuming far-field WPT, the budget power link as discussed in [71] can be described as follows: (cid:3047)(cid:3028) (cid:3047)(cid:3034) (cid:3033) (cid:3045)(cid:3028) (cid:2868) (cid:1840) (cid:3042) (cid:3045) (cid:3030) (cid:3031) (cid:1842) (cid:1833) (cid:1838) (cid:1833) (cid:1840) where P…”
Background
Metadata
- Authors
- Xia, W., Saito, K., Takahashi, M., & Ito, K.
- Venue
- IEEE Transactions on Antennas and Propagation
- Published
- 2009-04
- Volume
- 57
- Issue
- 4
- Pages
- 894-899
- ISSN
- 0018-926X (ISSN-L)
- OpenAlex
- W2143526797
- Cited by
- 250
- References
- 0
- FWCI
- 7.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performances of an Implanted Cavity Slot Antenna Embedded in the Human Arm. https://app.cochat.ai/papers/10.1109/tap.2009.2014579
- The paper
- Xia, W., Saito, K., Takahashi, M., & Ito, K. (2009). Performances of an Implanted Cavity Slot Antenna Embedded in the Human Arm. IEEE Transactions on Antennas and Propagation. https://doi.org/10.1109/tap.2009.2014579
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.