Wireless power transfer approaches for medical implants: a review

Open access
Haerinia, Mohammad, Shadid, Reem·2020·Signals

Abstract

Wireless power transmission (WPT) is a critical technology that provides an alternative for wireless power and communication with implantable medical devices (IMDs). This article provides a study concentrating on popular WPT techniques for IMDs including inductive coupling, microwave, ultrasound, and hybrid wireless power transmission (HWPT) systems. Moreover, an overview of the major works is analyzed with a comparison of the symmetric and asymmetric design elements, operating frequency, distance, efficiency, and harvested power. In general, with respect to the operating frequency, it is concluded that the ultrasound-based and inductive-based WPTs have a low operating frequency of less than 50 MHz, whereas the microwave-based WPT works at a higher frequency. Moreover, it can be seen that most of the implanted receiver’s dimension is less than 30 mm for all the WPT-based methods. Furthermore, the HWPT system has a larger receiver size compared to the other methods used. In terms of efficiency, the maximum power transfer efficiency is conducted via inductive-based WPT at 95%, compared to the achievable frequencies of 78%, 50%, and 17% for microwave-based, ultrasound-based, and hybrid WPT, respectively. In general, the inductive coupling tactic is mostly employed for transmission of energy to neuro-stimulators, and the ultrasonic method is used for deep-seated implants.

Integrity signals

Registry

Crossref · 10.3390/signals1020012

Cites

116 of 116 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • This frequency range minimizes eddy current losses, reducing the risk of localized heating and its subsequent influence on neural stability.

    “This range minimizes eddy current losses, thereby reducing the risk of localized heating and its subsequent influence on neural stability (Maaß et al., 2017; Haerinia and Shadid, 2020; Mahmood et al., 2022).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Haerinia and Shadid, 2020

  • A coupling coefficient k closer to 1 maximizes energy transfer and minimizes potential thermal damage to neural tissues.

    “A value closer to 1 not only maximizes energy transfer but also minimizes potential thermal damage to neural tissues—a concern for BMIs requiring high computational power for real-time neural decoding (Haerinia and Shadid, 2020; Khan et al., 2020).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Haerinia and Shadid, 2020

Cites

Flagged first, then by citations

2 of the 118 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Haerinia, M., & Shadid, R.
Affiliations
  • University of North Dakota (US)
  • Applied Science Private University (JO)
Corresponding author
Haerinia, Mohammad
Venue
Signals
Publisher
MDPI AG
Published
2020-12-16
Volume
1
Issue
2
Pages
209-229
ISSN
2624-6120 (ISSN-L)
OpenAlex
W3112882954
Cited by
174
References
118
Citations by year
2026: 15 · 2025: 41 · 2024: 41 · 2023: 36 · 2022: 33 · 2021: 8
FWCI
6.61
Type
journal article
Language
en
Open access
Locations
Signals (publishedVersion, cc-by)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Mechanical Engineering › Induction Heating and Inverter Technology
Keywords
wireless power transfer, biomedical implants, inductive coupling, microwave power transmission, power transfer efficiency, nerve stimulator

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review