Wireless Powering and the Study of RF Propagation Through Ocular Tissue for Development of Implantable Sensors
The DOI matches its Crossref record.
Abstract
This paper evaluates RF powering techniques, and corresponding propagation through tissue, to supply wireless-energy for miniature implantable devices used to monitor physical-conditions in real-time. To improve efficiencies an impulsive powering technique is used with short duty-cycle high instantaneous-power-bursts, which biases the rectifier in its nonlinear regime while maintaining low average input-powers. The RF rectifier consists of a modified two-stage voltage multiplier which produces the necessary turn-on voltage for standard low-power CMOS systems while supplying the required current levels. The rectifier, fabricated on the TI 130 nm CMOS process, measures 215 μm × 265 μm, and is integrated with an antenna to quantify wireless performance of the power transfer. In-vivo studies performed on New Zealand white rabbits demonstrate the ability of implanted CMOS RF rectifiers to produce 1 V across a 27 kΩ load at a distance of 5 cm with a transmit-power of just over 1.5 W. Using a pulsed-powering technique, the circuit generates just under 0.9 V output with an average transmit-power of 300 mW. The effects of implantation on the propagation of RF powering waves are quantified and demonstrated to be surmountable, allowing for the ability to supply a low-power wireless sensor through a miniature rectifier IC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless Charging Technologies: Fundamentals, Standards, and Network Applications
Lu, X., Wang, P., Niyato, D., Kim, D. I., & Han, Z. (2016) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2015.2499783 · Cited by 968
RF power harvesting: a review on designing methodologies and applications
Tran, L.-G., Cha, H.-K., & Park, W.-T. (2017) · Micro and Nano Systems Letters · doi:10.1186/s40486-017-0051-0 · Cited by 293
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Chow, E., Morris, M., & Irazoqui, P. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2248586 · Cited by 111
“Work done in [49] and [50] for ocular implant applications involved acute testing on live New Zealand white rabbit subjects, shown in Figure 4.”
BackgroundSelf-citationHigh-performance wireless powering for peripheral nerve neuromodulation systems
Tanabe, Y., Ho, J. S., Liu, J., Liao, S.-Y., Zhen, Z., Hsu, S., Shuto, C., Zhu, Z.-Y., Ma, A., Vassos, C., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186698 · Cited by 63
Metadata
- Authors
- Chow, E. Y., Yang, C.-L., Ouyang, Y., Chlebowski, A. L., Irazoqui, P. P., & Chappell, W. J.
- Venue
- IEEE Transactions on Antennas and Propagation
- Published
- 2011-06
- Volume
- 59
- Issue
- 6
- Pages
- 2379-2387
- ISSN
- 0018-926X (ISSN-L)
- 1558-2221
- OpenAlex
- W2105956876
- Cited by
- 67
- References
- 0
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless Powering and the Study of RF Propagation Through Ocular Tissue for Development of Implantable Sensors. https://app.cochat.ai/papers/10.1109/tap.2011.2144551
- The paper
- Chow, E. Y., Yang, C.-L., Ouyang, Y., Chlebowski, A. L., Irazoqui, P. P., & Chappell, W. J. (2011). Wireless Powering and the Study of RF Propagation Through Ocular Tissue for Development of Implantable Sensors. IEEE Transactions on Antennas and Propagation. https://doi.org/10.1109/tap.2011.2144551
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.