The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Highly Sensitive and Easy-to-Use SQUID Sensors
Abstract
We have developed a novel family of low-noise superconducting quantum interference devices (SQUIDs) to cover a wide range of applications. These sensors are robust and easy to use without compromising noise performance. They are optimized for operation with our high-speed direct-coupled flux-locked loop (FLL) electronics XXF-1. For the readout of cryogenic detectors, series arrays of 16 SQUIDs with 3 nH input inductance were designed which can be cooled down and operated in the Earth's field without magnetic shield. A compact gradiometric design allows the chips to be mounted directly on a Cu block at the cold stage of a mK cryostat without degradation in noise. A current noise level of 9 or 5 is achieved at 4.2 K or 300 mK, respectively. Ultra-high-speed operation was demonstrated by using a cold FLL electronics prototype in close proximity to the SQUID array. An extremely high FLL bandwidth of 350 MHz was achieved which outperforms any flux-locked SQUID before by more than an order of magnitude. For applications requiring a larger input inductance of up to 2 , integrated two-stage sensors were developed consisting of a single front-end SQUID with double-transformer coupling read out by a 16-SQUID array. These sensors are very convenient to use as their voltage-flux characteristic is essentially single-SQUID-like. Devices optimized for 4.2 K operation have a coupled energy resolution around 50 times Planck's constant . Heavily shunted devices for low-temperature operation typically achieve 80 or 8 at 4.2 K or 300 mK, respectively. An optional current limiter (Q-spoiler) at the input reduces the input current in pulsed applications like nuclear magnetic resonance or magnetorelaxometry. Integrated rf filters and resistor-capacitor shunts across the input coil result in smooth, well-behaved voltage-flux characteristics even at low temperatures 4.2 K. For magnetic field sensing applications, integrated miniature multiloop magnetometers were designed with maximized field resolution. For a 3 mm 3 mm chip size, a noise level of 3.6 is obtained at 4.2 K.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
dc SQUID: Noise and optimization
Tesche, C. D., & Clarke, J. (1977) · Journal of Low Temperature Physics · doi:10.1007/bf00655097 · Cited by 691
Critical Field for Complete Vortex Expulsion from Narrow Superconducting Strips
Stan, G., Field, S. B., & Martinis, J. M. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.097003 · Cited by 227
Low-frequency noise in dc superconducting quantum interference devices below 1 K
Wellstood, F. C., Urbina, C., & Clarke, J. (1987) · Applied Physics Letters · doi:10.1063/1.98041 · Cited by 206
Welty, R. P., & Martinis, J. M. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133821 · Cited by 170
High- T c and low- T c dc SQUID electronics
Drung, D. (2003) · Superconductor Science and Technology · doi:10.1088/0953-2048/16/12/002 · Cited by 146
Self-citationTwo-stage integrated SQUID amplifier with series array output
Welty, R. P., & Martinis, J. M. (1993) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.233523 · Cited by 139
Low-noise ultra-high-speed dc SQUID readout electronics
Drung, D., Hinnrichs, C., & Barthelmess, H.-J. (2006) · Superconductor Science and Technology · doi:10.1088/0953-2048/19/5/s15 · Cited by 76
Self-citationHigh-performance DC SQUID read-out electronics
Drung, D. (2002) · Physica C Superconductivity · doi:10.1016/s0921-4534(01)01154-6 · Cited by 60
Self-citationAn electronic second-order gradiometer for biomagnetic applications in clinical shielded rooms
Drung, D., & Koch, H. (1993) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.233526 · Cited by 51
Self-citation
Cited by
Science and technology roadmap for graphene, related two-dimensional crystals, and hybrid systems
Ferrari, A. C., Bonaccorso, F., Fal'ko, V., Novoselov, K. S., Roche, S., Bøggild, P., Borini, S., Koppens, F. H. L., Palermo, V., Pugno, N., et al. (2015) · Nanoscale · doi:10.1039/c4nr01600a · Cited by 3,027
Significant-Loophole-Free Test of Bell’s Theorem with Entangled Photons
Giustina, M., Versteegh, M. A. M., Wengerowsky, S., Handsteiner, J., Hochrainer, A., Phelan, K., Steinlechner, F., Kofler, J., Larsson, J.-Å., Abellán, C., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.115.250401 · Cited by 1,529
Self-citationUltrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
Bell violation using entangled photons without the fair-sampling assumption
Giustina, M., Mech, A., Ramelow, S., Wittmann, B., Kofler, J., Beyer, J., Lita, A., Calkins, B., Gerrits, T., Nam, S. W., et al. (2013) · Nature · doi:10.1038/nature12012 · Cited by 660
Self-citationOptical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
Metadata
- Authors
- Drung, D., Assmann, C., Beyer, J., Kirste, A., Peters, M., Ruede, F., & Schurig, T.
- Venue
- IEEE Transactions on Applied Superconductivity
- Published
- 2007-06
- Volume
- 17
- Issue
- 2
- Pages
- 699-704
- ISSN
- 1051-8223 (ISSN-L)
- OpenAlex
- W2113751765
- Cited by
- 348
- References
- 9
- FWCI
- 7.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly Sensitive and Easy-to-Use SQUID Sensors. https://app.cochat.ai/papers/10.1109/tasc.2007.897403
- The paper
- Drung, D., Assmann, C., Beyer, J., Kirste, A., Peters, M., Ruede, F., & Schurig, T. (2007). Highly Sensitive and Easy-to-Use SQUID Sensors. IEEE Transactions on Applied Superconductivity. https://doi.org/10.1109/tasc.2007.897403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.