Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 348

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Highly Sensitive and Easy-to-Use SQUID Sensors

Drung, D.., Assmann, C.., Beyer, J.., Kirste, A.., Peters, M.., Ruede, F.., Schurig, T..·2007·IEEE Transactions on Applied Superconductivity

Abstract

We have developed a novel family of low-noise superconducting quantum interference devices (SQUIDs) to cover a wide range of applications. These sensors are robust and easy to use without compromising noise performance. They are optimized for operation with our high-speed direct-coupled flux-locked loop (FLL) electronics XXF-1. For the readout of cryogenic detectors, series arrays of 16 SQUIDs with 3 nH input inductance were designed which can be cooled down and operated in the Earth's field without magnetic shield. A compact gradiometric design allows the chips to be mounted directly on a Cu block at the cold stage of a mK cryostat without degradation in noise. A current noise level of 9 or 5 is achieved at 4.2 K or 300 mK, respectively. Ultra-high-speed operation was demonstrated by using a cold FLL electronics prototype in close proximity to the SQUID array. An extremely high FLL bandwidth of 350 MHz was achieved which outperforms any flux-locked SQUID before by more than an order of magnitude. For applications requiring a larger input inductance of up to 2 , integrated two-stage sensors were developed consisting of a single front-end SQUID with double-transformer coupling read out by a 16-SQUID array. These sensors are very convenient to use as their voltage-flux characteristic is essentially single-SQUID-like. Devices optimized for 4.2 K operation have a coupled energy resolution around 50 times Planck's constant . Heavily shunted devices for low-temperature operation typically achieve 80 or 8 at 4.2 K or 300 mK, respectively. An optional current limiter (Q-spoiler) at the input reduces the input current in pulsed applications like nuclear magnetic resonance or magnetorelaxometry. Integrated rf filters and resistor-capacitor shunts across the input coil result in smooth, well-behaved voltage-flux characteristics even at low temperatures 4.2 K. For magnetic field sensing applications, integrated miniature multiloop magnetometers were designed with maximized field resolution. For a 3 mm 3 mm chip size, a noise level of 3.6 is obtained at 4.2 K.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tasc.2007.897403

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 348

Metadata

Authors
Drung, D., Assmann, C., Beyer, J., Kirste, A., Peters, M., Ruede, F., & Schurig, T.
Venue
IEEE Transactions on Applied Superconductivity
Published
2007-06
Volume
17
Issue
2
Pages
699-704
ISSN
1051-8223 (ISSN-L)
OpenAlex
W2113751765
Cited by
348
References
9
FWCI
7.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Sensitive and Easy-to-Use SQUID Sensors. https://app.cochat.ai/papers/10.1109/tasc.2007.897403
The paper
Drung, D., Assmann, C., Beyer, J., Kirste, A., Peters, M., Ruede, F., & Schurig, T. (2007). Highly Sensitive and Easy-to-Use SQUID Sensors. IEEE Transactions on Applied Superconductivity. https://doi.org/10.1109/tasc.2007.897403

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.