The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Stereoscopic 3D-TV: Visual Comfort
Abstract
Among the key topics of discussion and research on three-dimensional television (3D-TV), visual comfort is certainly one of the most critical. This is because it is well known that some viewers experience visual discomfort when looking at stereoscopic displays. It is important to properly address the issue of visual comfort to avoid possible delays in the deployment of 3D-TV. Here we present a concise overview of the main topics relevant to comfort in viewing stereoscopic television and survey the key factors influencing visual comfort. Potential end users of 3D-TV, content creators, program providers, broadcasters, display manufacturers and researchers will find this overview useful.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Eye movements in reading and information processing: 20 years of research
Rayner, K. (1998) · Psychological Bulletin · doi:10.1037/0033-2909.124.3.372 · Cited by 7,979
Cz., P. (1896) · Monatshefte für Mathematik und Physik · doi:10.1007/bf01708548 · Cited by 2,055
Vergence–accommodation conflicts hinder visual performance and cause visual fatigue
Hoffman, D. M., Girshick, A. R., Akeley, K., & Banks, M. S. (2008) · Journal of Vision · doi:10.1167/8.3.33 · Cited by 1,625
Depth-image-based rendering (DIBR), compression, and transmission for a new approach on 3D-TV:
Fehn, C. (2004) · SPIE Proceedings · doi:10.1117/12.524762 · Cited by 1,349
Wheatstone, C. (1838) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1838.0019 · Cited by 1,320
The Measurement, Instrumentation and Sensors Handbook
Webster, J. G. (1998) · CRC Press eBooks · doi:10.1201/9781003040019 · Cited by 1,029
Visual Discomfort and Visual Fatigue of Stereoscopic Displays: A Review
Lambooij, M., Fortuin, M., Heynderickx, I., & IJsselsteijn, W. (2009) · Journal of Imaging Science and Technology · doi:10.2352/j.imagingsci.technol.2009.53.3.030201 · Cited by 1,006
Helmholtz's treatise on physiological optics
(1924) · Journal of the Franklin Institute · doi:10.1016/s0016-0032(24)90484-4 · Cited by 696
Researches in Binocular Vision
(1951) · Journal of the American Medical Association · doi:10.1001/jama.1951.02920280080027 · Cited by 526
Handbook of the Psychology of Aging
(2006) · Elsevier eBooks · doi:10.1016/b978-0-12-101264-9.x5000-9 · Cited by 435
Cited by
Full-reference quality assessment of stereopairs accounting for rivalry
Chen, M.-J., Su, C.-C., Kwon, D.-K., Cormack, L. K., & Bovik, A. C. (2013) · Signal Processing: Image Communication · doi:10.1016/j.image.2013.05.006 · Cited by 383
Subjective evaluation of stereoscopic image quality
Moorthy, A. K., Su, C.-C., Mittal, A., & Bovik, A. C. (2013) · Signal Processing: Image Communication · doi:10.1016/j.image.2012.08.004 · Cited by 304
No-Reference Quality Assessment of Natural Stereopairs
Chen, M.-J., Cormack, L. K., & Bovik, A. C. (2013) · IEEE Transactions on Image Processing · doi:10.1109/tip.2013.2267393 · Cited by 268
Stereoscopic 3D displays and human performance: A comprehensive review
McIntire, J. P., Havig, P. R., & Geiselman, E. E. (2014) · Displays · doi:10.1016/j.displa.2013.10.004 · Cited by 225
Shao, F., Li, K., Lin, W., Jiang, G., Yu, M., & Dai, Q. (2015) · IEEE Transactions on Image Processing · doi:10.1109/tip.2015.2436332 · Cited by 116
Metadata
- Authors
- Tam, W. J., Speranza, F., Yano, S., Shimono, K., & Ono, H.
- Venue
- IEEE Transactions on Broadcasting
- Published
- 2011-06
- Volume
- 57
- Issue
- 2
- Pages
- 335-346
- ISSN
- 0018-9316 (ISSN-L)
- 1557-9611
- OpenAlex
- W2113059272
- Cited by
- 292
- References
- 33
- FWCI
- 72.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stereoscopic 3D-TV: Visual Comfort. https://app.cochat.ai/papers/10.1109/tbc.2011.2125070
- The paper
- Tam, W. J., Speranza, F., Yano, S., Shimono, K., & Ono, H. (2011). Stereoscopic 3D-TV: Visual Comfort. IEEE Transactions on Broadcasting. https://doi.org/10.1109/tbc.2011.2125070
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.