Cited by 155Analog and Mixed-Signal Circuit DesignNeuroscience and Neural EngineeringHearing Loss and Rehabilitation

A Low-Power Blocking-Capacitor-Free Charge-Balanced Electrode-Stimulator Chip With Less Than 6 nA DC Error for 1-mA Full-Scale Stimulation

Sit, Ji-Jon, Sarpeshkar, Rahul·2007·IEEE Transactions on Biomedical Circuits and Systems

Abstract

Large dc blocking capacitors are a bottleneck in reducing the size and cost of neural implants. We describe an electrode-stimulator chip that removes the need for large dc blocking capacitors in neural implants by achieving precise charge-balanced stimulation with <6 nA of dc error. For cochlear implant patients, this is well below the industry's safety limit of 25 nA. Charge balance is achieved by dynamic current balancing to reduce the mismatch between the positive and negative phases of current to 0.4%, followed by a shorting phase of at least 1 ms between current pulses to further reduce the charge error. On +6 and -9 V rails in a 0.7-mum AMI high voltage process, the power consumption of a single channel of this chip is 47 muW when biasing power is shared by 16 channels.

Integrity signals

Registry

Crossref · 10.1109/tbcas.2007.911631

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 18 · Cited by 155

Authors
Sit, J.-J., & Sarpeshkar, R.
Affiliations
  • Advanced Bionics (United States) (US)
  • Massachusetts Institute of Technology (US)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2007-09
Volume
1
Issue
3
Pages
172-183
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2165982740
Cited by
155
References
18
Citations by year
2026: 1 · 2025: 5 · 2024: 8 · 2023: 8 · 2022: 6 · 2021: 9 · 2020: 1 · 2019: 9 · 2018: 10 · 2017: 9 · 2016: 15 · 2015: 10 · 2014: 13 · 2013: 13 · 2012: 10
FWCI
4.54
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Hearing Loss and Rehabilitation
Keywords
charge balancing, neural implants, cochlear implants, low-power integrated circuits, high-voltage CMOS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review