The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
HermesD: A High-Rate Long-Range Wireless Transmission System for Simultaneous Multichannel Neural Recording Applications
Abstract
HermesD is a high-rate, low-power wireless transmission system to aid research in neural prosthetic systems for motor disabilities and basic motor neuroscience. It is the third generation of our "Hermes systems" aimed at recording and transmitting neural activity from brain-implanted electrode arrays. This system supports the simultaneous transmission of 32 channels of broadband data sampled at 30 ks/s, 12 b/sample, using frequency-shift keying modulation on a carrier frequency adjustable from 3.7 to 4.1 GHz, with a link range extending over 20 m. The channel rate is 24 Mb/s and the bit stream includes synchronization and error detection mechanisms. The power consumption, approximately 142 mW, is low enough to allow the system to operate continuously for 33 h, using two 3.6-V/1200-mAh Li-SOCl2 batteries. The transmitter was designed using off-the-shelf components and is assembled in a stack of three 28 mm ? 28-mm boards that fit in a 38 mm ? 38 mm ? 51-mm aluminum enclosure, a significant size reduction over the initial version of HermesD. A 7-dBi circularly polarized patch antenna is used as the transmitter antenna, while on the receiver side, a 13-dBi circular horn antenna is employed. The advantages of using circularly polarized waves are analyzed and confirmed by indoor measurements. The receiver is a stand-alone device composed of several submodules and is interfaced to a computer for data acquisition and processing. It is based on the superheterodyne architecture and includes automatic frequency control that keeps it optimally tuned to the transmitter frequency. The HermesD communications performance is shown through bit-error rate measurements and eye-diagram plots. The sensitivity of the receiver is -83 dBm for a bit-error probability of 10(-9). Experimental recordings from a rhesus monkey conducting multiple tasks show a signal quality comparable to commercial acquisition systems, both in the low-frequency (local field potentials) and upper-frequency bands (action potentials) of the neural signals. This system can be easily scaled up in terms of the number of channels and data rate to accommodate future generations of Hermes systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A low-power integrated circuit for a wireless 100-electrode neural recording system.
Harrison, R. R., Watkins, P. T., Kier, R. J., Lovejoy, R. O., Black, D. J., Greger, B., & Solzbacher, F. (2007) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.886567 · Cited by 782
Wireless Implantable Microsystems: High-Density Electronic Interfaces to the Nervous System
Wise, K. D., Anderson, D. J., Hetke, J. F., Kipke, D. R., & Najafi, K. (2004) · Proceedings of the IEEE · doi:10.1109/jproc.2003.820544 · Cited by 656
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Cited by
Neural population dynamics during reaching
Churchland, M. M., Cunningham, J. P., Kaufman, M. T., Foster, J. D., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2012) · Nature · doi:10.1038/nature11129 · Cited by 1,626
Self-citationDesign and Optimization of a 3-Coil Inductive Link for Efficient Wireless Power Transmission
Kiani, M., Jow, U.-M., & Ghovanloo, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2158431 · Cited by 591
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Nanotools for Neuroscience and Brain Activity Mapping
Alivisatos, A. P., Andrews, A. M., Boyden, E. S., Chun, M., Church, G. M., Deisseroth, K., Donoghue, J. P., Fraser, S. E., Lippincott-Schwartz, J., Looger, L. L., et al. (2013) · ACS Nano · doi:10.1021/nn4012847 · Cited by 356
Chronic, wireless recordings of large-scale brain activity in freely moving rhesus monkeys
Schwarz, D. A., Lebedev, M. A., Hanson, T. L., Dimitrov, D. F., Lehew, G., Meloy, J., Rajangam, S., Subramanian, V., Ifft, P. J., Li, Z., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2936 · Cited by 348
Metadata
- Authors
- Miranda, H., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2010-06
- Volume
- 4
- Issue
- 3
- Pages
- 181-191
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2148841250
- Cited by
- 161
- References
- 3
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HermesD: A High-Rate Long-Range Wireless Transmission System for Simultaneous Multichannel Neural Recording Applications. https://app.cochat.ai/papers/10.1109/tbcas.2010.2044573
- The paper
- Miranda, H., Gilja, V., Chestek, C. A., Shenoy, K. V., & Meng, T. H. (2010). HermesD: A High-Rate Long-Range Wireless Transmission System for Simultaneous Multichannel Neural Recording Applications. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2010.2044573
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.