Cited by 102Analog and Mixed-Signal Circuit DesignWireless Body Area NetworksCardiac pacing and defibrillation studies

A Programmable Implantable Microstimulator SoC With Wireless Telemetry: Application in Closed-Loop Endocardial Stimulation for Cardiac Pacemaker

Open access
Lee, Shuenn-Yuh, Su, Mario YuCheng, Liang, Ming-Chun, Chen, You-Yin, Hsieh, Cheng-Han, Yang, Chung-Min, Lai, Hsin-Yi, Lin, Jou-Wei +1 more·2011·IEEE Transactions on Biomedical Circuits and Systems

Abstract

A low-power, wireless, and implantable microstimulator system on chip with smart powering management, immediate neural signal acquisition, and wireless rechargeable system is proposed. A system controller with parity checking handles the adjustable stimulus parameters for the stimulated objective. In the current paper, the rat's intra-cardiac electrogram is employed as the stimulated model in the animal study, and it is sensed by a low-voltage and low-power monitoring analog front end. The power management unit, which includes a rectifier, battery charging and detection, and a regulator, is used for the power control of the internal circuits. The stimulation data and required clock are extracted by a phase-locked-loop-based phase shift keying demodulator from an inductive AC signal. The full chip, which consumes 48 μW only, is fabricated in a TSMC 0.35 μm 2P4M standard CMOS process to perform the monitoring and pacing functions with inductively powered communication in the in vivo study.

Integrity signals

Registry

Crossref · 10.1109/tbcas.2011.2177661

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Inductive power transfer introduces bioengineering challenges due to Specific Absorption Rate limits and minimal size capacity for device implantation.

    “However, inductive power transfer introduces numerous bioengineering challenges due to Specific Absorption Rate (SAR) limits and minimal size capacity for device implantation.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lee, S.-Y., Su, M. Y., Liang, M.-C., Chen, Y.-Y., Hsieh, C.-H., Yang, C.-M., Lai, H.-Y., Lin, J.-W., & Fang, Q.
Affiliations
  • National Chung Cheng University (TW)
  • National Yang Ming University (TW)
  • National Yang Ming Chiao Tung University (TW)
  • National Taiwan University (TW)
  • Melbourne Institute of Technology (AU)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2011-12
Volume
5
Issue
6
Pages
511-522
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2031790846
Cited by
102
References
1
Citations by year
2026: 3 · 2025: 4 · 2024: 2 · 2023: 4 · 2022: 6 · 2021: 9 · 2020: 10 · 2019: 6 · 2018: 9 · 2017: 6 · 2016: 6 · 2015: 15 · 2014: 3 · 2013: 13 · 2012: 5
FWCI
4.17
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
  • RMIT Research Repository (RMIT University Library) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
Funders
  • RMIT University
  • Johnson and Johnson
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
system-on-chip, cardiac pacemaker, wireless telemetry, inductive power transfer, wireless charging, power management, phase-locked loop demodulation, phase-shift keying, low-power analog front-end, parity check, rat model

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review