A 1.83 $\mu$J/Classification, 8-Channel, Patient-Specific Epileptic Seizure Classification SoC Using a Non-Linear Support Vector Machine
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A non-linear support vector machine (NLSVM) seizure classification SoC with 8-channel EEG data acquisition and storage for epileptic patients is presented. The proposed SoC is the first work in literature that integrates a feature extraction (FE) engine, patient specific hardware-efficient NLSVM classification engine, 96 KB SRAM for EEG data storage and low-noise, high dynamic range readout circuits. To achieve on-chip integration of the NLSVM classification engine with minimum area and energy consumption, the FE engine utilizes time division multiplexing (TDM)-BPF architecture. The implemented log-linear Gaussian basis function (LL-GBF) NLSVM classifier exploits the linearization to achieve energy consumption of 0.39 μ J/operation and reduces the area by 28.2% compared to conventional GBF implementation. The readout circuits incorporate a chopper-stabilized DC servo loop to minimize the noise level elevation and achieve noise RTI of 0.81 μ Vrms for 0.5-100 Hz bandwidth with an NEF of 4.0. The 5 × 5 mm (2) SoC is implemented in a 0.18 μm 1P6M CMOS process consuming 1.83 μ J/classification for 8-channel operation. SoC verification has been done with the Children's Hospital Boston-MIT EEG database, as well as with a specific rapid eye-blink pattern detection test, which results in an average detection rate, average false alarm rate and latency of 95.1%, 0.94% (0.27 false alarms/hour) and 2 s, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
(2010) · doi:10.5555/1756006.1859921 · Cited by 1,924
EEG-based neonatal seizure detection with Support Vector Machines
Temko, A., Thomas, E., Marnane, W., Lightbody, G., & Boylan, G. (2011) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.06.034 · Cited by 339 · cited 1×
“2386891 clinically visible and only 1/10 of them are reported [3].”
BackgroundA 48.6-to-105.2 µW Machine Learning Assisted Cardiac Sensor SoC for Mobile Healthcare Applications
Hsu, S.-Y., Ho, Y., Chang, P.-Y., Su, C., & Lee, C.-Y. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2297406 · Cited by 82
Cited by
Bin Altaf, M. A., Zhang, C., & Yoo, J. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2015.2482498 · Cited by 192
“The implemented D(2)A classification processor needs to process 16 channels for its FE, where each FE channel is comprised of seven filter banks (46-tap); therefore, implementing the FE is hardware costly [12], [43].”
BackgroundMethodInfluentialSelf-citationA Noninvasive Glucose Monitoring SoC Based on Single Wavelength Photoplethysmography
Hina, A., & Saadeh, W. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.2979514 · Cited by 99
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
Dabbaghian, A., Yousefi, T., Fatmi, S. Z., Shafia, P., & Kassiri, H. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2936327 · Cited by 56
Metadata
- Authors
- Bin Altaf, M. A., & Yoo, J.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2016-02
- Volume
- 10
- Issue
- 1
- Pages
- 49-60
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2018642663
- Cited by
- 134
- References
- 4
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 1.83 $\mu$J/Classification, 8-Channel, Patient-Specific Epileptic Seizure Classification SoC Using a Non-Linear Support Vector Machine. https://app.cochat.ai/papers/10.1109/tbcas.2014.2386891
- The paper
- Bin Altaf, M. A., & Yoo, J. (2016). A 1.83 $\mu$J/Classification, 8-Channel, Patient-Specific Epileptic Seizure Classification SoC Using a Non-Linear Support Vector Machine. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2014.2386891
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.