A 16-Channel Patient-Specific Seizure Onset and Termination Detection SoC With Impedance-Adaptive Transcranial Electrical Stimulator
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
A 16-channel noninvasive closed-loop beginning-and end-of-seizure detection SoC is presented. The dual-channel charge recycled (DCCR) analog front end (AFE) achieves chopping and time-multiplexing an amplifier between two channels simultaneously which exploits fast-settling DC servo-loop with current consumption and NEF of 0.9 μA/channel and 3.29/channel, respectively. The dual-detector architecture (D2A) classification processor utilizes two linear support-vector machine (LSVM) classifiers based on digital hysteresis to enhance both the sensitivity and the specificity simultaneously. The pulsating voltage transcranial electrical stimulator (PVTES) automatically configures the number of pulses to control the amount of charge delivered based on skin-electrode impedance variation in efforts to suppress the seizure activity, while burning only 2.45 μW. The 25 mm2SoC implemented in 0.18 μm CMOS consumes 2.73 μJ/classification for 16 channels with an average sensitivity, specificity, and latency of 95.7%, 98%, and 1 s, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Application of machine learning to epileptic seizure onset detection and treatment
Shoeb, A. H. (2009) · DSpace@MIT (Massachusetts Institute of Technology) · Cited by 1,426
Moshé, S. L., Perucca, E., Ryvlin, P., & Tomson, T. (2015) · The Lancet · doi:10.1016/s0140-6736(14)60456-6 · Cited by 905 · cited 1×
“E PILEPSY is a severe and chronic neurological disorder that affects more than 65 million people worldwide [1].”
BackgroundVerma, N., Shoeb, A., Bohorquez, J., Dawson, J., Guttag, J., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2042245 · Cited by 526 · cited 1×
“Multichannel electroencephalogram (EEG) seizure detection SoCs are widely adopted in medical practice and in research [7], [18], but these have following limitations.”
BackgroundClosed-Loop Control of Epilepsy by Transcranial Electrical Stimulation
Berényi, A., Belluscio, M., Mao, D., & Buzsáki, G. (2012) · Science · doi:10.1126/science.1223154 · Cited by 476 · cited 1×
“Antiepileptic drugs are the standard treatment for controlling and reducing epileptic seizures, but around 30% of patients cannot be effectively treated with medication [2].”
BackgroundFan, Q., Sebastiano, F., Huijsing, J. H., & Makinwa, K. A. A. (2011) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2143610 · Cited by 473
Brain stimulation for epilepsy
Theodore, W. H., & Fisher, R. S. (2004) · The Lancet Neurology · doi:10.1016/s1474-4422(03)00664-1 · Cited by 410
A Minimally Invasive 64-Channel Wireless μECoG Implant
Muller, R., Le, H.-P., Li, W., Ledochowitsch, P., Gambini, S., Bjorninen, T., Koralek, A., Carmena, J. M., Maharbiz, M. M., Alon, E., et al. (2015) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2364824 · Cited by 372 · cited 1×
“29/channel, which is superior over that of [10]–[12], [33], [35]–[38].”
BackgroundChen, W.-M., Chiueh, H., Chen, T.-J., Ho, C.-L., Jeng, C., Ker, M.-D., Lin, C.-Y., Huang, Y.-C., Chou, C.-W., Fan, T.-Y., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2013.2284346 · Cited by 279 · cited 3×
“45 μW) compared [18], [48], [49], [51] and unlike [14], [48] there is no need”
BackgroundFrontal lobe seizures: From clinical semiology to localization
Bonini, F., McGonigal, A., Trébuchon, A., Gavaret, M., Bartolomei, F., Giusiano, B., & Chauvel, P. (2014) · Epilepsia · doi:10.1111/epi.12490 · Cited by 275 · cited 2×
“[28] indicates that the interval between seizure electrical onset and clinical onset varies from 0.”
Background
Cited by
Casson, A. J. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-018-00093-6 · Cited by 340
Zhang, M., Tang, Z., Liu, X., & Van der Spiegel, J. (2020) · Nature Electronics · doi:10.1038/s41928-020-0390-3 · Cited by 231
Zhu, B., Shin, U., & Shoaran, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3112756 · Cited by 67
“Later, a combination of two linear SVMs was introduced [13] to address this limitation, Fig.”
BackgroundMethodInfluentialRozgic, D., Hokhikyan, V., Jiang, W., Akita, I., Basir - Kazeruni, S., Chandrakumar, H., & Markovic, D. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2889040 · Cited by 49
Design Considerations for Implantable Neural Circuits and Systems
Hsu, W.-Y., Hsieh, P.-H., & Chen, H. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_19 · Cited by 1
Metadata
- Authors
- Bin Altaf, M. A., Zhang, C., & Yoo, J.
- Venue
- IEEE Journal of Solid-State Circuits
- Published
- 2015-11
- Volume
- 50
- Issue
- 11
- Pages
- 2728-2740
- ISSN
- 0018-9200 (ISSN-L)
- 1558-173X
- OpenAlex
- W1906184128
- Cited by
- 192
- References
- 41
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 16-Channel Patient-Specific Seizure Onset and Termination Detection SoC With Impedance-Adaptive Transcranial Electrical Stimulator. https://app.cochat.ai/papers/10.1109/jssc.2015.2482498
- The paper
- Bin Altaf, M. A., Zhang, C., & Yoo, J. (2015). A 16-Channel Patient-Specific Seizure Onset and Termination Detection SoC With Impedance-Adaptive Transcranial Electrical Stimulator. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2015.2482498
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.