Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 199

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

A Versatile Embedded Platform for EMG Acquisition and Gesture Recognition

Open access
Benatti, Simone, Casamassima, Filippo, Milosevic, Bojan, Farella, Elisabetta, Schonle, Philipp, Fateh, Schekeb, Burger, Thomas, Huang, Qiuting, Benini, Luca·2015·IEEE Transactions on Biomedical Circuits and Systems

Abstract

Wearable devices offer interesting features, such as low cost and user friendliness, but their use for medical applications is an open research topic, given the limited hardware resources they provide. In this paper, we present an embedded solution for real-time EMG-based hand gesture recognition. The work focuses on the multi-level design of the system, integrating the hardware and software components to develop a wearable device capable of acquiring and processing EMG signals for real-time gesture recognition. The system combines the accuracy of a custom analog front end with the flexibility of a low power and high performance microcontroller for on-board processing. Our system achieves the same accuracy of high-end and more expensive active EMG sensors used in applications with strict requirements on signal quality. At the same time, due to its flexible configuration, it can be compared to the few wearable platforms designed for EMG gesture recognition available on market. We demonstrate that we reach similar or better performance while embedding the gesture recognition on board, with the benefit of cost reduction. To validate this approach, we collected a dataset of 7 gestures from 4 users, which were used to evaluate the impact of the number of EMG channels, the number of recognized gestures and the data rate on the recognition accuracy and on the computational demand of the classifier. As a result, we implemented a SVM recognition algorithm capable of real-time performance on the proposed wearable platform, achieving a classification rate of 90%, which is aligned with the state-of-the-art off-line results and a 29.7 mW power consumption, guaranteeing 44 hours of continuous operation with a 400 mAh battery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2015.2476555

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 199

Metadata

Authors
Benatti, S., Casamassima, F., Milosevic, B., Farella, E., Schonle, P., Fateh, S., Burger, T., Huang, Q., & Benini, L.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2015-10
Volume
9
Issue
5
Pages
620-630
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2180884865
Cited by
199
References
3
FWCI
8.65
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Versatile Embedded Platform for EMG Acquisition and Gesture Recognition. https://app.cochat.ai/papers/10.1109/tbcas.2015.2476555
The paper
Benatti, S., Casamassima, F., Milosevic, B., Farella, E., Schonle, P., Fateh, S., Burger, T., Huang, Q., & Benini, L. (2015). A Versatile Embedded Platform for EMG Acquisition and Gesture Recognition. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2015.2476555

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.