A Flexible, Micro-Lens-Coupled LED Stimulator for Optical Neuromodulation
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Optogenetics is a fast growing neuromodulation method, which can remotely manipulate the specific activities of genetically-targeted neural cells and associated biological behaviors with millisecond temporal precision through light illumination. Application of optogenetics in neuroscience studies has created an increased need for the development of light sources and the instruments for light delivery. This paper presents a micro-lens-coupled LED neural stimulator which includes a backside reflector and a frontside microlens for light collection and collimation. The device structure has been optimized using optical simulation and the optimized device is able to increase the volume of excitable tissues by 70.4%. Device prototypes have been fabricated and integrated based on an optimization of the device structure. The measurement results show that the light power increases by 99% at an effective penetration depth of 5 000 [Formula: see text] by the fabricated device under various voltages of 2.4-3.2 V.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In recent years, profiting from the academic interest and deep exploration in neuroscience, flexible implantable stimulators with various mechanisms (electrical,[521–523] optogenetic,[524,525] ultrasonic,[526,527] magnetic[528]) are being developed as non-pharmacological treatment options.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [523]
Citations
Cites
Millisecond-timescale, genetically targeted optical control of neural activity
Boyden, E. S., Zhang, F., Bamberg, E., Nagel, G., & Deisseroth, K. (2005) · Nature Neuroscience · doi:10.1038/nn1525 · Cited by 4,861 · cited 1×
“Unlike electrical neuromodulation that suffers from indiscriminate activation of cell components (somas, dendrites, and axons) [8], optogenetic neuromodulation uniquely combines cell type-specific control with millisecond time scale temporal resolution in a fully reversible manner [9].”
BackgroundChannelrhodopsin-2, a directly light-gated cation-selective membrane channel
Nagel, G., Szellas, T., Huhn, W., Kateriya, S., Adeishvili, N., Berthold, P., Ollig, D., Hegemann, P., & Bamberg, E. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1936192100 · Cited by 2,663
Deisseroth, K. (2011) · Nature Methods · doi:10.1038/nmeth.f.324 · Cited by 1,863
High-performance genetically targetable optical neural silencing by light-driven proton pumps
Chow, B. Y., Han, X., Dobry, A. S., Qian, X., Chuong, A. S., Li, M., Henninger, M. A., Belfort, G. M., Lin, Y., Monahan, P. E., et al. (2010) · Nature · doi:10.1038/nature08652 · Cited by 1,186
Aravanis, A. M., Wang, L.-P., Zhang, F., Meltzer, L. A., Mogri, M. Z., Schneider, M. B., & Deisseroth, K. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/s02 · Cited by 970
Light-activated ion channels for remote control of neuronal firing
Banghart, M., Borges, K., Isacoff, E., Trauner, D., & Kramer, R. H. (2004) · Nature Neuroscience · doi:10.1038/nn1356 · Cited by 726
Optogenetic interrogation of neural circuits: technology for probing mammalian brain structures
Zhang, F., Gradinaru, V., Adamantidis, A. R., Durand, R., Airan, R. D., de Lecea, L., & Deisseroth, K. (2010) · Nature Protocols · doi:10.1038/nprot.2009.226 · Cited by 692 · cited 1×
“can be achieved by selecting appropriate promoters, for example, CaMKII α for targeting excitatory neurons, glial fibrillary acidic protein (GFAP) for targeting astrocytes, and ppHcrt promoter for targeting hypocretin neurons [10], [11].”
Halorhodopsin is a light-driven chloride pump.
Schobert, B., & Lanyi, J. K. (1982) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)34020-1 · Cited by 576
Enhanced light out-coupling of organic light-emitting devices using embedded low-index grids
Sun, Y., & Forrest, S. R. (2008) · Nature Photonics · doi:10.1038/nphoton.2008.132 · Cited by 576 · cited 1×
“stimulators for optogenetic applications [20], [21].”
Millisecond-Timescale Optical Control of Neural Dynamics in the Nonhuman Primate Brain
Han, X., Qian, X., Bernstein, J. G., Zhou, H.-H., Franzesi, G. T., Stern, P., Bronson, R. T., Graybiel, A. M., Desimone, R., & Boyden, E. S. (2009) · Neuron · doi:10.1016/j.neuron.2009.03.011 · Cited by 495
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
A Review: Electrode and Packaging Materials for Neurophysiology Recording Implants
Yang, W., Gong, Y. P., & Li, W. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.622923 · Cited by 120
“PA is also optically transparent with the transmission of 65–80 % over a spectrum range of 470 to 850 nm (Kwon et al., 2013; Alt et al., 2016; Bi et al., 2016), applicable for packaging many optical devices (Ledochowitsch et al., 2011; Park et al., 2014).”
BackgroundSelf-citationLight-emitting metalenses and meta-axicons for focusing and beaming of spontaneous emission
Mohtashami, Y., DeCrescent, R. A., Heki, L. K., Iyer, P. P., Butakov, N. A., Wong, M. S., Alhassan, A. I., Mitchell, W. J., Nakamura, S., DenBaars, S. P., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23433-0 · Cited by 81
Soltan, A., McGovern, B., Drakakis, E. M., Neil, M. A. A., Maaskant, P. P., Akhter, M., Lee, J. S., & Degenaar, P. A. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2623949 · Cited by 43
Mao, D., Sun, F. Y., Driscoll, B., Li, Z., & Xu, G. (2023) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2023.101702 · Cited by 19
Inductively coupled, mm-sized, single channel optical neuro-stimulator with intensity enhancer
Khan, W., Jia, Y., Madi, F., Weber, A. J., Ghovanloo, M., & Li, W. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0061-6 · Cited by 18
Self-citationMicro-Reflector Integrated Multichannel μLED Optogenetic Neurostimulator With Enhanced Intensity
Khan, W., Setien, M. B., Purcell, E. K., & Li, W. (2018) · Frontiers in Mechanical Engineering · doi:10.3389/fmech.2018.00017 · Cited by 14
Self-citationEmara, M. S., Pisanello, M., Sileo, L., Vittorio, M. D., & Pisanello, F. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2882146 · Cited by 14
“to overtake the activation threshold of excitatory and inhibitory opsins (∼1mW/mm2 and∼7mW/mm2, respectively) [54], [55]”
BackgroundA miniaturized, wirelessly-powered, reflector-coupled single channel opto neurostimulator
Khan, W., Jia, Y., Madi, F., Weber, A. J., Ghovanloo, M., & Li, W. (2018) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2018.8346512 · Cited by 10
“Furthermore, surfacemounted stimulation sources and data acquisition systems suffer from deficiency in penetrating into the volumetric depths of the tissues, which poses a significant challenge in their operations [6].”
BackgroundSelf-citationDesign study of a micro illumination platform based on GaN microLED arrays
Vito, A. D., Amiri, P., Bornemann, S., Schöttler, G., Vergin, M., Meierhofer, F., Gülink, J., Waag, A., Canals, J., Dieguez, A., et al. (2023) · Applied Optics · doi:10.1364/ao.498432 · Cited by 7
Khan, W., & Li, W. (2017) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2017.7994521 · Cited by 7
“Despite their many benefits, the μ-LEDs suffer from considerable radiation loss because of their low outcoupling efficiency and wide radiation angles due to the Lambertian emission pattern[12].”
BackgroundSelf-citationTowards a free-floating wireless implantable optogenetic stimulating system
Jia, Y., Lee, B., Mirbozorgi, S. A., Ghovanloo, M., Khan, W., & Li, W. (2017) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas.2017.8052940 · Cited by 6
Self-citationSingle-channel opto-neurostimulators: a review
Yang, W., Khan, W., Wu, J., & Li, W. (2019) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/ab003d · Cited by 6
“μ-LEDs can be driven by battery [43], inductive power telemetry [41], or ultrasonic powering interfaces [44] to achieve truly untethered optoelectronic systems for optogenetics studies in freely moving subjects [45, 46].”
BackgroundSelf-citationModular Optoelectronic System for Wireless, Programmable Neuromodulation During Free Behavior
Orguc, S., Sands, J., Sahasrabudhe, A., Anikeeva, P., & Chandrakasan, A. P. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175600 · Cited by 6
Single-unit metalens integrated micro light-emitting diodes
Kim, Y., Cho, J.-W., Bae, D., & Kim, S. (2024) · Current Applied Physics · doi:10.1016/j.cap.2024.07.016 · Cited by 5
A Temperature-Aware Fully-Wireless mm-Scale Optically-Enhanced Optogenetic Neuro-Stimulator
Yousefi, T., Timonina, K., Zoidl, G., & Kassiri, H. (2021) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas49922.2021.9644947 · Cited by 4
Duque-Afonso, C. J. (2020) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-8106 · Cited by 4
Optical propagation of blue LED light in brain tissue and Parylene-C
Xie, T., Bi, X., Luo, R., Fan, B., Wang, Z., & Li, W. (2017) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2017.8017094 · Cited by 4
“Among various light sources, micro-light-emitting diodes (μ-LEDs) are favored for its high power efficiency, low cost, and capability of complex system integration [10-16].”
BackgroundSelf-citationA Laser Diode-Based Wireless Optogenetic Headstage
Mesri, A., Sampietro, M., Cunha, A. B., Ferrari, G., & Martinsen, Ø. G. (2018) · Conference on Ph.D. Research in Microelectronics and Electronics · doi:10.1109/prime.2018.8430348 · Cited by 3
“Different methods are proposed to improve LED fiber coupling [7-9].”
GaN LEDs fabricated using SF 6 plasma RIE
Khan, W., Bi, X., Fan, B., & Li, W. (2018) · Micro & Nano Letters · doi:10.1049/mnl.2018.5083 · Cited by 2
Self-citationKanda, R., Kitade, T., Nishikawa, A., Loesing, A., & Sekiguchi, H. (2024) · physica status solidi (a) · doi:10.1002/pssa.202400051 · Cited by 1
P‐67: Printed Reflective Sloped Wall for Enhancing Luminance of ColorConversion Light Source
Lee, S., Kim, G., Oh, E., & Hong, Y. (2019) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.13222
Implementation of Optogenetics Technique for Neuron Photostimulation: A Physical Approach
Bharadwaj, S., Mena, S., & Kothari, D. P. (2019) · Springer eBooks · doi:10.1007/978-981-13-7142-4_15
Design of Micro-LED Array Short Focal Length Projection System
Zhiqiang, Z., Xu, Y., Zhang, Y., Xiaoyu, L., & Kang, Z. (2023) · Mechanical Science and Engineering · doi:10.57237/j.mse.2023.02.001
伟, 魏., 军, 邹., 宋金德, 刚, 乐., 仇成群, 林金填, 磊, 陈., 熊敬康, 郭浩中, & 张国义 (2026) · 半导体视界 · doi:10.63385/sh.v2i1.67
Metadata
- Authors
- Bi, X., Xie, T., Fan, B., Khan, W., Guo, Y., & Li, W.
- Affiliations
- Michigan State University (US)
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2016-10
- Volume
- 10
- Issue
- 5
- Pages
- 972-978
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2522712323
- Semantic Scholar
- 68e6ab48b1f02ac28f6b4d10f465c81373bb4513
- Cited by
- 24
- References
- 28
- Citations by year
- 2024: 2 · 2023: 3 · 2021: 4 · 2020: 2 · 2019: 4 · 2018: 5 · 2017: 4
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (ECCS-1055269)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Photoreceptor and optogenetics research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced optical system design
- Keywords
- optogenetics, optical neuromodulation, light collimation, light delivery, light penetration depth
- MeSH terms
- Equipment Design, Lenses, Lighting, Miniaturization, Photic Stimulation, Pilot Projects, Electric Power Supplies, Semiconductors, Equipment Failure Analysis, Optogenetics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.