Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 201

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

A Neural Probe With Up to 966 Electrodes and Up to 384 Configurable Channels in 0.13 $\mu$m SOI CMOS

Mora Lopez, Carolina, Putzeys, Jan, Raducanu, Bogdan Cristian, Ballini, Marco, Wang, Shiwei, Andrei, Alexandru, Rochus, Veronique, Vandebriel, Roeland, Severi, Simone, Van Hoof, Chris, Musa, Silke, Van Helleputte, Nick, Yazicioglu, Refet Firat, Mitra, Srinjoy · 2017 · IEEE Transactions on Biomedical Circuits and Systems

Abstract

In vivo recording of neural action-potential and local-field-potential signals requires the use of high-resolution penetrating probes. Several international initiatives to better understand the brain are driving technology efforts towards maximizing the number of recording sites while minimizing the neural probe dimensions. We designed and fabricated (0.13-μm SOI Al CMOS) a 384-channel configurable neural probe for large-scale in vivo recording of neural signals. Up to 966 selectable active electrodes were integrated along an implantable shank (70 μm wide, 10 mm long, 20 μm thick), achieving a crosstalk of -64.4 dB. The probe base (5 × 9 mm2) implements dual-band recording and a 171.6 Mbps digital interface. Measurement results show a total input-referred noise of 6.4 μVrmsand a total power consumption of 49.1 μW/channel.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2016.2646901

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 201

Metadata

Authors
Mora Lopez, C., Putzeys, J., Raducanu, B. C., Ballini, M., Wang, S., Andrei, A., Rochus, V., Vandebriel, R., Severi, S., Van Hoof, C., Musa, S., Van Helleputte, N., Yazicioglu, R. F., & Mitra, S.
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2017-06
Volume
11
Issue
3
Pages
510-522
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2607299631
Cited by
201
References
6
FWCI
9.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.