The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Miniature Passive Pressure Transensor for Implanting in the Eye
Abstract
A newly developed method for measurement of intraocular and other physiological pressures consists of a novel displacement transducer contained in a distensible pillbox small enough (3 to 60 μl) to be implanted in the eye of a small laboratory animal. Nothing pierces or even touches the globe. This passive resonant transensor absorbs energy from an oscillating detector coil outside of the animal at a frequency dependent upon the pressure in the eye. Passive operation provides extended life, but limits useful range to less than 10 transducer diameters, which has proved sufficient for intraocular pressure measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Terman, F. E. (1943) · Virtual Defense Library (Ministerio de Defensa) · Cited by 1,017
MACKAY, R. S., & JACOBSON, B. (1957) · Nature · doi:10.1038/1791239a0 · Cited by 207
CCK (1938) · Optometry and Vision Science · doi:10.1097/00006324-193803000-00004 · Cited by 82
Radio Telemetering from within the Body
Mackay, R. S. (1961) · Science · doi:10.1126/science.134.3486.1196 · Cited by 55
Erratum: Mechanism of Inactivation of Enzyme Proteins by Ultraviolet Light
(1961) · Science · doi:10.1126/science.134.3488.1410-a · Cited by 30
Evoked Pressure Responses in the Rabbit Eye
Collins, C. C. (1967) · Science · doi:10.1126/science.155.3758.106 · Cited by 20
Self-citation
Cited by
A biomechanical paradigm for axonal insult within the optic nerve head in aging and glaucoma
Burgoyne, C. F. (2011) · Experimental Eye Research · doi:10.1016/j.exer.2010.09.005 · Cited by 394
Capacitive sensors: When and how to use them
Puers, R. (1993) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(93)80019-d · Cited by 333
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
LC Passive Wireless Sensors Toward a Wireless Sensing Platform: Status, Prospects, and Challenges
Huang, Q.-A., Dong, L., & Wang, L.-F. (2016) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2016.2602298 · Cited by 284
Chen, P.-J., Saati, S., Varma, R., Humayun, M. S., & Tai, Y.-C. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2010.2049825 · Cited by 264
Metadata
- Authors
- Collins, C. C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1967-04
- Volume
- BME-14
- Issue
- 2
- Pages
- 74-83
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2083584485
- Cited by
- 282
- References
- 6
- FWCI
- 9.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.