Selection of the Number and Positions of Measuring Locations for Electrocardiography
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This paper considers how many and which locations on the body surface must be measured (by taking ECGs at these positions) to be able to determine consistently the total-body QRS surface-potential distribution as it varies in time. The answers to these questions have implications about the complexity of models of heart electrical activity in addition to their experimental value. An advantage of using the ability to compute the total-body potential distribution as a criterion of quality is that untestable assumptions about the nature of heart electrical activity are avoided. The accuracy of computed potential distributions with respect to corresponding experimental ones is specified by the mean-square difference between them. Acceptable maps had an average relative mean square error of less than 4 percent in the presence of about 1 percent noise, since inspection of the surface maps showed this to be the maximum error allowable for the same clinical or physiological interpretation of the surface maps analyzed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adjustment of an Inverse Matrix Corresponding to a Change in One Element of a Given Matrix
Sherman, J., & Morrison, W. J. (1950) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177729893 · Cited by 1,402
Distribution of heart potentials on the thoracic surface of normal human subjects
TACCARDI, B. (1963) · Circulation Research · doi:10.1161/01.res.12.4.341 · Cited by 337
Cited by
Rundo, F., Conoci, S., Ortis, A., & Battiato, S. (2018) · Sensors · doi:10.3390/s18020405 · Cited by 143
“In our validation setup a standard Einthoven triangle leads configuration for acquiring a robust ECG signal is employed [39,40].”
MethodOptimal magnetic sensor vests for cardiac source imaging
Lau, S., Petković, B., & Haueisen, J. (2016) · Sensors · doi:10.3390/s16060754 · Cited by 17
Metadata
- Authors
- Barr, R. C., Spach, M. S., & Herman-Giddens, G. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1971-03
- Volume
- BME-18
- Issue
- 2
- Pages
- 125-138
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2066226646
- Cited by
- 182
- References
- 2
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Selection of the Number and Positions of Measuring Locations for Electrocardiography. https://app.cochat.ai/papers/10.1109/tbme.1971.4502813
- The paper
- Barr, R. C., Spach, M. S., & Herman-Giddens, G. S. (1971). Selection of the Number and Positions of Measuring Locations for Electrocardiography. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1971.4502813
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.