Cited by 143Non-Invasive Vital Sign MonitoringECG Monitoring and AnalysisHeart Rate Variability and Autonomic Control

An Advanced Bio-Inspired PhotoPlethysmoGraphy (PPG) and ECG Pattern Recognition System for Medical Assessment

Open access
Rundo, Francesco, Conoci, Sabrina, Ortis, Alessandro, Battiato, Sebastiano·2018·Sensors

Abstract

Physiological signals are widely used to perform medical assessment for monitoring an extensive range of pathologies, usually related to cardio-vascular diseases. Among these, both PhotoPlethysmoGraphy (PPG) and Electrocardiography (ECG) signals are those more employed. PPG signals are an emerging non-invasive measurement technique used to study blood volume pulsations through the detection and analysis of the back-scattered optical radiation coming from the skin. ECG is the process of recording the electrical activity of the heart over a period of time using electrodes placed on the skin. In the present paper we propose a physiological ECG/PPG “combo” pipeline using an innovative bio-inspired nonlinear system based on a reaction-diffusion mathematical model, implemented by means of the Cellular Neural Network (CNN) methodology, to filter PPG signal by assigning a recognition score to the waveforms in the time series. The resulting “clean” PPG signal exempts from distortion and artifacts is used to validate for diagnostic purpose an EGC signal simultaneously detected for a same patient. The multisite combo PPG-ECG system proposed in this work overpasses the limitations of the state of the art in this field providing a reliable system for assessing the above-mentioned physiological parameters and their monitoring over time for robust medical assessment. The proposed system has been validated and the results confirmed the robustness of the proposed approach.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s18020405

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • For reliable detection in skin layers, LEDs and photodiodes must ideally operate in wavelength range of absorption peaks of blood hemoglobin and deoxyhemoglobin, between 540 and 570 nm.

    “For reliable detection in these skin layers, the used LEDs (respectively, light sources) and photodiodes PDs must ideally operate in the wavelength range of the absorption peaks of blood hemoglobin and deoxyhemoglobin, i.e., between 540 and 570 nm [77].”

    From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [77]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 5

  1. [8]Shin H.S. Jung S.J. Kim J. Chung W. Real Time car driver’s condition monitoring system Proceedings of the IEEE Sensors Conference Kona, HI, USA 1–4 November 2010 951 954
  2. [22]Yang L. Chua L.O. Krieg K.R. VLSI implementation of cellular neural networks Proceedings of the IEEE International Symposium on Circuits and Systems New Orleans, LA, USA 1–3 May 1990 2425 2427
  3. [25]Chua L.O. Yang L. Cellular neural networks Proceedings of the IEEE International Symposium on Circuits and Systems Kobe, Japan 19–24 June 1988 985 988
  4. [29]Box P.G.E. Jenkins G.M. Reinsel G.C. Time Series Analysis: Forecasting and Control 3rd ed. Prentice Hall Englewood Cliffs, NJ, USA 1994
  5. [41]Battiato S. Gallo G. Stanco F. A new edge-adaptive zooming algorithm for digital images Proceedings of the Signal Processing and Communications Conference Lake Louise, AB, Canada 4 October 2000 144 149

Cited by

Sorted by citations

Authors
Rundo, F., Conoci, S., Ortis, A., & Battiato, S.
Affiliations
  • STMicroelectronics (Italy) (IT)
  • STMicroelectronics—ADG Central R&D, 95121 Catania, Italy
  • University of Catania (IT)
Corresponding author
Rundo, Francesco
Venue
Sensors
Publisher
MDPI AG
Published
2018-01-30
Volume
18
Issue
2
Pages
405
ISSN
1424-8220 (ISSN-L)
OpenAlex
W2793412197
Cited by
143
References
37
Citations by year
2026: 6 · 2025: 9 · 2024: 14 · 2023: 7 · 2022: 21 · 2021: 28 · 2020: 22 · 2019: 31 · 2018: 5
FWCI
8.60
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
Keywords
photoplethysmography, electrocardiogram, PPG signal denoising, ECG signals, reaction-diffusion systems, cellular neural networks, bio-inspired signal processing, cardiovascular disease diagnosis, physiological monitoring, artifact removal
MeSH terms
Electrocardiography, Heart Rate, Humans, Pattern Recognition, Automated, Signal Processing, Computer-Assisted, Artifacts, Photoplethysmography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review