CoChat

Extracellular Potential Recordings by Means of a Field Effect Transistor Without Gate Metal, Called OSFET

Bergveld, Piet, Wiersma, Jelle, Meertens, Harm · 1976 · IEEE Transactions on Biomedical Engineering
Cited by 103

The DOI matches its Crossref record.

Abstract

The design and operation of a new semiconductor element, based upon the field effect principle is discussed. The device, which is called an OSFET, can be used as a measuring electrode for bioelectric activity. The OSFET consists of an MOS-transistor configuration, where the gate metal has been omitted and can be used directly in the extracellular fluid as an active probe. The operation of the OSFET is described by a physical-mathematical model, by means of which it is possible to explain the results of electrophysiological measurements. These results are compared with the results of a computer simulation, in which the Rosenfalck equation for extracellular potential distributions serves as an input for the OSFET model stated. A special electronic circuit is used to perform low impedance measurements in a simple way with the OSFET electrode. It appears that extracellular potentials measured with an OSFET-electrode have an extended frequency range, with respect to conventional potential measurements (0 ⩽< f ⩽< 45 K c/s).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.1976.324574

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Bergveld, P., Wiersma, J., & Meertens, H.
Venue
IEEE Transactions on Biomedical Engineering
Published
1976-03
Volume
BME-23
Issue
2
Pages
136-144
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2085187133
Cited by
103
References
0
FWCI
0.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.