Electrocutaneous Nerve Stimulation-I: Model and Experiment
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The behavior of nerve fibers in the skin during electrocutaneous stimulation has been studied in this investigation for the purpose of understanding the influence of various current pulse parameters. One part of the investigation assessed the amount of stimulus charge, for various pulse parameters, required to depolarize the nodal membrane of myelinated nerve, using the Frankenhaeuser-Huxley model for Xenopus Laevis (toad). The second part of the investigation involved the experimental application of biphasic current pulses via a concentric electrode to the skin of a number of human subjects. The subjects were asked to match the intensity of sensation as stimulus parameters were varied. The experimental results were compared to the predictions of the model by the process of normalization for temperature differences and the loss of electrode current in adjacent passive tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
Cited by
Flexible Electronics: The Next Ubiquitous Platform
Nathan, A., Ahnood, A., Cole, M. T., Lee, S., Suzuki, Y., Hiralal, P., Bonaccorso, F., Hasan, T., Garcia-Gancedo, L., Dyadyusha, A., et al. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2190168 · Cited by 1,000
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Electrocutaneous Stimulation for Sensory Communication in Rehabilitation Engineering
Szeto, A. Y. J., & Saunders, F. A. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324948 · Cited by 223
Sensory Effects of Transient Electrical Stimulation - Evaluation with a Neuroelectric Model
Reilly, J. P., Freeman, V. T., & Larkin, W. D. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325509 · Cited by 195
“Despite this simplification, single-node models have provided substantial insight into neuronal properties [1], [2].”
BackgroundMethodModeling axon membranes for functional electrical stimulation
Rattay, F., & Aberham, M. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250575 · Cited by 174
Electrical stimulation of peripheral nerve
Swett, J. E., & Bourassa, C. M. (1981) · Electrical Stimulation Research Techniques · doi:10.1016/b978-0-12-547440-5.50016-4 · Cited by 39
Metadata
- Authors
- Butikofer, R., & Lawrence, P. D.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1978-11
- Volume
- BME-25
- Issue
- 6
- Pages
- 526-531
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2077365603
- Cited by
- 54
- References
- 1
- FWCI
- 0.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.